10010004 | 10010005 | 10010007 | 10010008 | 10010009 | 10010010 | 10010011 | 10010012 | 10010013 | 10010014 | 10010015 | 10010016 | 10010017 | 10010018 | 10010019 | 10010020 | 10010021 | 10010022 | 10010023 | 10010024 | 10010025 | 10010026 | 10010027 | 10010028 | 10010029 | 10010030 | 10010031 | 10010032 | 10010033 | 10010034 | 10010035 | 10010036 | 10010037 | 10010038 | 10010039 | 10010040 | 10010041 | 10010042 | 10010043 | 10010044 | 10010045 | 10010046 | 10010047 | 10010048 | 10010049 | 10010050 | 10010150 | 10010151 | 10010152 | 10010153 | 10010154 | 10010200 | 10010201 | 10010202 | 10010203 | 10010204 | 10010205 | 10010206 | 10010207 | 10010208 | 10010209 | 10010210 | 10010211 | 10010212 | 10010213 | 10010215 | 10010216 | 10010217 | 10010218 | 10010219 | 10010220

10010004 Not enough memory to receive request
Explanation

The RPC server does not have enough memory to receive the client request.

Action

If your server is a Natural RPC Server, increase the MAXBUFF memory parameter.


10010005 Out of memory
Explanation

The RPC server is unable to allocate enough memory to fulfill the request.

Action

Increase the memory resources of your RPC server.


10010007 Internal error [Response <number> from RPC Server]
Explanation

The RPC server returned an internal error. A more specific error <number> may follow.

Action
  1. See the trace on the server and/or client side and contact Software AG support.

  2. See under error <number> for an explanation and action to take.


10010008 Unknown version
Explanation

This error message is returned in the following situations:

  1. The RPC protocol version you requested is not supported by your RPC server.

  2. The server command is not known.

  3. There is an error in the RPC protocol header.

Action

Depending on the situation above, for

  1. If possible, upgrade your RPC server or use only those data types supported by your RPC server in the IDL file.

  2. See the trace on the server and/or client side and contact Software AG support.


10010009 Invalid format buffer
Explanation

The format buffer within the RPC protocol could not be parsed.

Action

Contact Software AG support.


10010010 Invalid value buffer
Explanation

The value buffer within the RPC protocol could not be parsed.

Action

Contact Software AG support.


10010011 Invalid packet type
Explanation

The packet type shipped with the RPC protocol is not valid.

Action

Contact Software AG support.


10010012 Authorization or initialization failed
Explanation

One of the following occurred on the RPC server side:

  1. A Natural RPC Server secured by Natural Security denied access because the Natural RPC Security ticket could not be evaluated correctly or is missing.

  2. Initialization of a Natural RPC Server failed.

  3. An EntireX z/OS CICS® RPC Server secured by CICS security denied the user's request.

Action

Depending on the situation described above, check your security configuration on the server side.


10010013 No match with pattern
Explanation

Natural RPC Server message.

Action

Contact Software AG support.


10010014 Wrong Version of SYSRPC
Explanation

Natural RPC Server message.

Action

Contact Software AG support.


10010015 Recursive RPC tried
Explanation

Natural RPC Server message.

Action

Contact Software AG support.


10010016 Callee not found. Lib=<Library>, Pgm=<Program>[,<Natural Error Info>]
Explanation

The RPC server did not find the server program. This message can be appended by Natural error information:

[,(Natural Error Info: Program=<NAT Pgm>,Error=<NAT Error>,
                       Line=<NAT Line>,Status=<NAT Status>,Level=<NAT Level>)]
<NAT Pgm>       The Natural Program name which caused the error.
<NAT Error>     The Natural Error number.
<NAT Line>      The Line number within the erronous program which caused the error.
<NAT Status>    See Natural Documentation.
<NAT Level>     See Natural Documentation.

See the Natural documentation.

Action

Depending on the type of your RPC server, one of the following situations may apply:

  1. If the server is an EntireX RPC server on Windows/UNIX:

    • The server stub with the name D<library>.dll on Windows or D<library>.so/sl on UNIX must be accessible to the EntireX RPC server. The program called must be available within that library as an export named D<program>.

    • The same applies to the server program. A server with the name <library>.dll on Windows or <library>.so|sl UNIX must be accessible to the EntireX RPC server. The program called must be available within that library as an export named <program>.

    Check read/execution access, library names and exports.

  2. If the server is an EntireX RPC server on CICS:

    • A program named <program> must exist in the DFHRPL-steplib concatenation.

    • The program must be CSD-defined and (depending on CICS version) must be installed.

  3. If the server is a Natural RPC Server:

    • If Natural Logon is switched on for the request or conversation, the program must be found within the target library (or its steplib concatenation).

    • If Natural Logon is switched off for the request or conversation, the program must be found in the initial library (or its steplib concatenation) of the Natural RPC Server.

    See also the appropriate Natural documentation.

  4. If the Server is an EntireX XML/SOAP RPC Server:

    • The server classes must be accessible from the EntireX XML/SOAP RPC Server.

    • Make sure that the path of the server classes is in the classpath.

  5. If the server is an EntireX RPC server in Batch or IMS and the program is implemented in C language:

    • The RPC configuration parameter MARSHALLING=(LANGUAGE=C) must be defined.


10010017 Reserved for internal use

10010018 Abnormal termination during program execution. Lib=<Library>, Pgm=<Program>[,<Natural Error Info>]
Explanation

The stub or the program/method called by the RPC server ended abnormally. This message can be appended by Natural error information:

[,(Natural Error Info: Program=<NAT Pgm>,Error=<NAT Error>,
                       Line=<NAT Line>,Status=<NAT Status>,Level=<NAT Level>)]
<NAT Pgm>       The Natural Program name which caused the error.
<NAT Error>     The Natural Error number.
<NAT Line>      The Line number within the erronous program which caused the error.
<NAT Status>    See the Natural documentation.
<NAT Level>     See the Natural documentation.
Action

Correct the program/method called by the RPC server.


10010019 Response from user program out of range
Explanation

The program/method called by the RPC server can return application errors within the range 1 - 9999. The user error is outside of this range.

Action

Check your program/method called by the RPC server and correct the error.


10010020 Reserved for internal use

10010021 Invalid header
Explanation

The header within the RPC protocol is invalid.

Action

See the trace on the server and/or client side and contact Software AG support.


10010022 Unknown server command
Explanation

The RPC protocol contains an unknown server command.

Action

Contact Software AG support.


10010023 Stub parameter definition error
Explanation

The parameter definitions within the stub called by the RPC server are different. This error code is typical if clients send data using an older RPC protocol. The code will be detected by the RPC server to adjust its call information.

Action

When working with the UNIX or Windows RPC server, no action is required if the error message appears just once per call. Multiple appearances indicate a general problem: re-generate your stubs with the template file server.tpl, compile and link them. If the error persists, contact Software AG support.


10010024 Parameter out of value range
Explanation

The value range for a parameter is outside the defined range.
Example:
An I1 data type is mapped to a 2-byte integer type in a programming language environment where there is no 1-byte integer type. The range is defined in the interface specification, that is, the IDL file. See Software AG IDL File.
For I1 it is from -127 to 128. The mapping to a 2-byte integer permits a program to set values less than -127 or greater than 128 which is not allowed for I1.

Action

Check program and correct error.


10010025 Parameter max len or array bound required
Explanation

This error message is returned in the following situations:

  1. The RPC server cannot handle variable-length data types such as AV, BV and KV without maximum lengths.

  2. The RPC server cannot handle arrays with variable bounds without maximum upper bounds.

Action

Depending on the situation above, for

  1. Specify maximum values for the variable-length data types in the IDL file. See Software AG IDL File.

  2. Specify maximum values for the upper bounds of the array in the IDL file.


10010026 Invalid string buffer
Explanation

Internal error in the string buffer of the RPC protocol.

Action

Contact Software AG support.


10010027 Parse error
Explanation

The RPC server cannot parse the RPC protocol.

Action

Contact Software AG support.


10010028 Library not found
Explanation

The RPC server did not find the library or class given in the RPC protocol.

Action

Check your configuration, server programs and stubs and the library name sent by the client.


10010029 Invalid eyecatcher
Explanation

The header of the RPC protocol contains an invalid eyecatcher.

Action

Contact Software AG support.


10010030 Parameter array bounds overflow
Explanation

An overflow occurs with an unbounded array whose maximum array bounds are determined in the IDL file. See Software AG IDL File.

Action

Check program and correct error.


10010031 String buffer item overflow of the RPC protocol
Explanation

Internal error in string buffer.

Action

Contact Software AG support.


10010032 Reserved for internal use

10010033 Invalid unbounded array
Explanation

During marshalling/unmarshalling on the server side an error occurred when accessing the unbounded array.

Action

One of the following may apply:

  1. The unbounded array was destroyed by your server program. Check the program and correct the error.

  2. An internal error occurred in the RPC server. Contact Software AG support.


10010034 Unbounded array does not match IDL file
Explanation

The data type and attributes of the unbounded array sent to the server do not match the data type or attributes of the unbounded array within the server stub.

Action

Re-generate, compile and link your server stub using the same IDL file as on the client side.


10010035 Conversation already open
Explanation

The client application issues an open conversation RPC request having the conversation already opened.

Action

Contact Software AG support.


10010036 Conversation already closed
Explanation

The client application issues a close conversation, close conversation commit or conversational RPC request without having any open conversation.

Action

Contact Software AG support.


10010037 Non-conv call within open conversation
Explanation

The client application issues a non-conversational RPC request while having an open conversation.

Action

Contact Software AG support.


10010038 Reserved for internal use

10010039 Error code converted to <encoding>, error code is <error code>
Explanation

The RPC server does not reply in the correct encoding.

  • <encoding> ASCII when the RPC server answers in ASCII but EBCDIC is expected

    EBCDIC when the RPC server answers in EBCDIC but ASCII is expected

  • <error code> The error code replied by the Server.

Action

Check that Internationalization is correctly configured for the broker. See Internationalization with EntireX.


10010040 Error code cannot be decoded
Explanation

The RPC server does not reply in the correct encoding.

Action

Check that Internationalization is correctly configured for the broker. See Internationalization with EntireX. Check that the server you are communicating with is an RPC server and not, for example, an ACI server.


10010041 Optional parameters not supported by RPC Server
Explanation

The RPC server does not support optional parameters. Optional parameters are supported by Natural RPC Servers. EntireX RPC servers do not support optional parameters.

Action

Contact Software AG support to check whether a newer version of the Natural RPC Server may support the feature.


10010042 Maximum supported depth for Group levels is <level>
Explanation

The maximum level for groups is 99.

Action

Correct your application.


10010043 Change Password not supported by RPC Server
Explanation

You tried to use the Change Password feature of the RPC protocol with an RPC server that does not support this feature.

Action

Do not try to change the password with this RPC server.


10010044 Natural RPC client stub required
Explanation

The IDL you are using contains features which require a Natural client interface object (stub).

Action

Generate a Natural client interface object and use it with the RPC client.


10010045 CICS ABEND <myabend> was issued
Explanation

This error indicates an application error code. Application error codes enable the RPC server to return customer-invented errors back to the RPC client in a standardized way without defining an error code field in the IDL.

Here the CICS RPC Server received a CICS ABEND code forced by the application server program using the EXEC CICS ABEND ABCODE(myabend). The ABEND starts with a letter other than "A" and follows the rules for CICS user ABEND codes. The ABEND code (myabend) can be used in the RPC client to gain information about specific application error situations of the server.

For more information see Using EXEC CICS ABEND ABCODE in the COBOL Wrapper documentation.

Action

The error code can be used in RPC clients to test for specific application error codes.


10010046 Inconsistent RPC request or Reliable RPC message
Explanation

The string buffer item "REL" shipped with the RPC protocol is not valid with RPC request.

Action

Contact Software AG support.


10010047 Invalid value area
Explanation

The value area in the SVM file could not be parsed.

Action

Contact Software AG support.


10010048 Inconsistent Reliable RPC message
Explanation

The string buffer item "REL" is missing or invalid.

Action

Contact Software AG support.


10010049 Invalid packet type for Reliable RPC
Explanation

The packet type shipped with the RPC protocol is not valid for the use of reliable RPC. The string buffer item "REL" is not valid for the packet type.

Action

Contact Software AG support.


10010050 Illegal parameter direction
Explanation

Reliable RPC allows only IDL direction IN parameters.

Action

Update your IDL, i.e. remove any OUT and INOUT parameters, possibly re-generate your interface object and/or update your application, then retry the RPC call.


10010150 Format Buffer Check: direction does not match. Request of IDL field (<type-length>), location=<location>
Explanation

The EntireX RPC server detected an inconsistency between the deployed SVM entry and the IDL file with which the RPC client was built. The direction-attribute (IN, OUT, INOUT) of a parameter (see attribute-list under Software AG IDL Grammar) defined in the IDL file is different to the direction-attribute in the related SVM entry.

Possible causes:

The message provides additional information such as <type-length> and <location>, where

  • <type-length> matches the IDL data type; see IDL Data Types

  • <location> contains the hierarchy of IDL nodes, separated by a colon

Example: IDL field (NU14.0), location=3.2.1.

The IDL below was used for the RPC call. The location is interpreted as follows: Third field on level 1 is 'G-parameter-3-on-level-1'; then second parameter on level 2 is the array 'G-parameter-32-on-level-2'; then the first field on level 3 which is 'G-parameter-322-on-level-3' produced the error.

. . .
define data parameter
1 G-parameter-1-on-level-1       (A10) In
1 G-parameter-2-on-level-1             In
1 G-parameter-3-on-level-1             Out
   2 G-parameter-31-on-level-2
      3 G-parameter-311-on-level-3 (A5)
      3 G-parameter-312-on-level-3 (N8)
      3 G-parameter-313-on-level-3 (NU4)
   2 G-parameter-32-on-level-2    (/25)
      3 G-parameter-322-on-level-3 (NU14)
      3 G-parameter-321-on-level-3 (A5)
1 G-parameter-4-on-level-1      (A64)
. . .
end-define
Action

Make sure the IDL file and the deployed SVM file are consistent. Possibly redeploy the SVM file, see Server Mapping Deployment.


10010151 Format Buffer Check: data type does not match. Request of IDL field (<type-length>), location=<location>
Explanation

The EntireX RPC server detected an inconsistency between the deployed SVM entry and the IDL file with which the RPC client was built. The sequence of IDL data types (see IDL Data Types under Software AG IDL File) defined in the IDL file is different to the sequence in the related SVM entry. See error message 10010150 for possible causes of this situation.

Additional information for <type-length> and <location> is explained under error message 10010150.

Action

Make sure the IDL file and the deployed SVM file are consistent. Possibly redeploy the SVM file, see Server Mapping Deployment. If the problem persists, reextract or rewrap and then redeploy.


10010152 Format Buffer Check: length is not equal. Request of IDL field (<type-length>), location=<location>
Explanation

The EntireX RPC server detected an inconsistency between the deployed SVM entry and the IDL file with which the RPC client was built. The length definition of a parameter (see simple-parameter-definition under Software AG IDL Grammar) defined in the IDL file is different to the length definition in the related SVM entry. See error message 10010150 for possible causes of this situation.

Additional information for <type-length> and <location> is explained under 10010150.

Action

Make sure the IDL file and the deployed SVM file are consistent. Possibly redeploy the SVM file, see Server Mapping Deployment. If the problem persists, reextract or rewrap and then redeploy.


10010153 Format Buffer Check: attributes not matching. Request of IDL field (<type-length>), location=<location>
Explanation

The EntireX RPC server detected an inconsistency between the deployed SVM entry and the IDL file with which the RPC client was built. The attributes of a parameter (see attribute-list under Software AG IDL Grammar) defined in the IDL file are different to the attributes in the related SVM entry. See error message 10010150 for possible causes of this situation.

Additional information for <type-length> and <location> is explained under 10010150.

Action

Make sure the IDL file and the deployed SVM file are consistent. Possibly redeploy the SVM file, see Server Mapping Deployment. If the problem persists, reextract or rewrap and then redeploy.


10010154 Format Buffer Check: indices not matching. Request of IDL field (<type-length>), location=<location>
Explanation

The EntireX RPC server detected an inconsistency between the deployed SVM entry and the IDL file with which the RPC client was built. Either the number of dimensions (one-, two- three-dimensional) or the upper bounds (see array-definition) do not match. See error message 10010150 for possible causes of this situation.

Additional information for <type-length> and <location> is explained under 10010150.

Action

Make sure the IDL file and the deployed SVM file are consistent. Possibly redeploy the SVM file, see Server Mapping Deployment. If the problem persists, reextract or rewrap and then redeploy.


10010200 Parameter Error: data not unsigned numeric. <direction> of IDL field [<parameter-name>] (<type-length>), location=<location>
Explanation

An application parameter cannot be processed because its content does not match the expected format unsigned numeric (NU). See IDL Data Types.

The message provides additional information such as <direction>, <parameter-name>, <type-length> and <location>, where

  • <direction> is either 'Request' if the error was detected before the RPC server was executed, or 'Reply' for the answer, i.e. if the RPC server was already executed.

  • <parameter-name> is available for target programming language C only

  • <type-length> matches the IDL data type; see IDL Data Types

  • <location> contains the hierarchy of IDL nodes, separated by a colon. If an IDL node is an array, its indexes are given in parentheses.

Example: Reply of IDL field (NU14.0), location=3.2(I=5).1.

The IDL below was used for the RPC call. The location is interpreted as follows: Third field on level 1 is 'G-parameter-3-on-level-1'; then second parameter on level 2 is the array 'G-parameter-32-on-level-2'and (I=5) means the fifth occurrence; then the first field on level 3 which is 'G-parameter-322-on-level-3' produced the error.

. . .
define data parameter
1 G-parameter-1-on-level-1       (A10) In
1 G-parameter-2-on-level-1             In
1 G-parameter-3-on-level-1             Out
   2 G-parameter-31-on-level-2
      3 G-parameter-311-on-level-3 (A5)
      3 G-parameter-312-on-level-3 (N8)
      3 G-parameter-313-on-level-3 (NU4)
   2 G-parameter-32-on-level-2    (/25)
      3 G-parameter-322-on-level-3 (NU14)
      3 G-parameter-321-on-level-3 (A5)
1 G-parameter-4-on-level-1      (A64)
. . .
end-define
Action

Make sure the IDL file, optionally the SVM file and your server application are consistent. Check your server application for parameter integrity.


10010201 Parameter Error: data not signed numeric. <direction> of IDL field [<parameter-name>] (<type-length>), location=<location>
Explanation

An application parameter cannot be processed because its content does not match the expected format signed numeric (N). See IDL Data Types.

The additional information <direction>, <parameter-name>, <type-length> and <location> is explained under error message 10010200.

Action

Make sure the IDL file, optionally the SVM file and your server application are consistent. Check your server application for parameter integrity.


10010202 Parameter Error: data not numeric. <direction> of IDL field [<parameter-name>] (<type-length>), location=<location>
Explanation

An application parameter cannot be processed because its content does not match the expected format unsigned numeric (NU) or signed numeric (N). See IDL Data Types.

The additional information <direction>, <parameter-name>, <type-length> and <location> is explained under error message 10010200.

Action

Make sure the IDL file, optionally the SVM file and your server application are consistent. Check your server application for parameter integrity.


10010203 Parameter Error: data not unsigned packed. <direction> of IDL field [<parameter-name>] (<type-length>), location=<location>
Explanation

An application parameter cannot be processed because its content does not match the expected format unsigned packed (PU). See IDL Data Types.

The additional information <direction>, <parameter-name>, <type-length> and <location> is explained under error message 10010200.

Action

Make sure the IDL file, optionally the SVM file and your server application are consistent. Check your server application for parameter integrity.


10010204 Parameter Error: data not signed packed. <direction> of IDL field [<parameter-name>] (<type-length>), location=<location>
Explanation

An application parameter cannot be processed because its content does not match the expected format signed packed (P). See IDL Data Types.

The additional information <direction>, <parameter-name>, <type-length> and <location> is explained under error message 10010200.

Action

Make sure the IDL file, optionally the SVM file and your server application are consistent. Check your server application for parameter integrity.


10010205 Parameter Error: data not packed. <direction> of IDL field [<parameter-name>] (<type-length>), location=<location>
Explanation

An application parameter cannot be processed because its content does not match the expected format unsigned packed (PU) or signed packed (P). See IDL Data Types.

The additional information <direction>, <parameter-name>, <type-length> and <location> is explained under error message 10010200.

Action

Make sure the IDL file, optionally the SVM file and your server application are consistent. Check your server application for parameter integrity.


10010206 Parameter Error: I1 < MIN. <direction> of IDL field [<parameter-name>] (<type-length>), location=<location>
Explanation

An application parameter of IDL type I1 cannot be processed because its content is less than the allowed minimum (-128) for I1. See IDL Data Types.

The additional information <direction>, <parameter-name>, <type-length> and <location> is explained under error message 10010200.

Action

Make sure the IDL file, optionally the SVM file and your server application are consistent. Check your server application for parameter integrity.


10010207 Parameter Error: I1 > MAX. <direction> of IDL field [<parameter-name>] (<type-length>), location=<location>
Explanation

An application parameter of IDL type I1 cannot be processed because its content is greater than the allowed maximum (+127) for I1. See IDL Data Types.

The additional information <direction>, <parameter-name>, <type-length> and <location> is explained under error message 10010200.

Action

Make sure the IDL file, optionally the SVM file and your server application are consistent. Check your server application for parameter integrity.


10010208 Parameter Error: I2 < MIN. <direction> of IDL field [<parameter-name>] (<type-length>), location=<location>
Explanation

An application parameter of IDL type I2 cannot be processed because its content is less than the allowed minimum (-32768) for I2. See IDL Data Types.

The additional information <direction>, <parameter-name>, <type-length> and <location> is explained under error message 10010200.

Action

Make sure the IDL file, optionally the SVM file and your server application are consistent. Check your server application for parameter integrity.


10010209 Parameter Error: I2 > MAX. <direction> of IDL field [<parameter-name>] (<type-length>), location=<location>
Explanation

An application parameter of IDL type I2 cannot be processed because its content is greater than the allowed maximum (+32767) for I2. See IDL Data Types.

The additional information <direction>, <parameter-name>, <type-length> and <location> is explained under error message 10010200.

Action

Make sure the IDL file, optionally the SVM file and your server application are consistent. Check your server application for parameter integrity.


10010210 Parameter Error: I4 < MIN. <direction> of IDL field [<parameter-name>] (<type-length>), location=<location>
Explanation

An application parameter of IDL type I4 cannot be processed because its content is less than the allowed minimum (-2147483648) for I4. See IDL Data Types.

The additional information <direction>, <parameter-name>, <type-length> and <location> is explained under error message 10010200.

Action

Make sure the IDL file, optionally the SVM file and your server application are consistent. Check your server application for parameter integrity.


10010211 Parameter Error: I4 > MAX. <direction> of IDL field [<parameter-name>] (<type-length>), location=<location>
Explanation

An application parameter of IDL type I2 cannot be processed because its content is greater than the allowed maximum (+2147483647) for I2. See IDL Data Types.

The additional information <direction>, <parameter-name>, <type-length> and <location> is explained under error message 10010200.

Action

Make sure the IDL file, optionally the SVM file and your server application are consistent. Check your server application for parameter integrity.


10010212 Parameter Error: float < MIN. <direction> of IDL field [<parameter-name>] (<type-length>), location=<location>
Explanation

An application parameter of IDL type F4 cannot be processed because its content is less than the allowed minimum (1.175494351e-38F) for F4. See IDL Data Types.

The additional information <direction>, <parameter-name>, <type-length> and <location> is explained under error message 10010200.

Action

Make sure the IDL file, optionally the SVM file and your server application are consistent. Check your server application for parameter integrity.


10010213 Parameter Error: float > MAX. <direction> of IDL field [<parameter-name>] (<type-length>), location=<location>
Explanation

An application parameter of IDL type F4 cannot be processed because its content is greater than the allowed maximum (3.402823466e+38F) for F4. See IDL Data Types.

The additional information <direction>, <parameter-name>, <type-length> and <location> is explained under error message 10010200.

Action

Make sure the IDL file, optionally the SVM file and your server application are consistent. Check your server application for parameter integrity.


10010215 Parameter Error: float HUGE_VAL. <direction> of IDL field [<parameter-name>] (<type-length>), location=<location>
Explanation

An application parameter of IDL type F4 cannot be processed because of conversation error HUGE_VAL (see C library strtod() for more information). The additional information <direction>, <parameter-name>, <type-length> and <location> is explained under error message 10010200.

Action

Make sure the IDL file, optionally the SVM file and your server application are consistent. Check your server application for parameter integrity.


10010216 Parameter Error: double < MIN. <direction> of IDL field [<parameter-name>] (<type-length>), location=<location>
Explanation

An application parameter of IDL type F8 cannot be processed because its content is less than the allowed minimum (2.2250738585072014e-308) for F8. See IDL Data Types.

The additional information <direction>, <parameter-name>, <type-length> and <location> is explained under error message 10010200.

Action

Make sure the IDL file, optionally the SVM file and your server application are consistent. Check your server application for parameter integrity.


10010217 Parameter Error: double > MAX. <direction> of IDL field [<parameter-name>] (<type-length>), location=<location>
Explanation

An application parameter of IDL type F8 cannot be processed because its content is greater than the allowed maximum (1.7976931348623158e+308) for F8. See IDL Data Types.

The additional information <direction>, <parameter-name>, <type-length> and <location> is explained under error message 10010200.

Action

Make sure the IDL file, optionally the SVM file and your server application are consistent. Check your server application for parameter integrity.


10010218 Parameter Error: double exponent over-, underflow. <direction> of IDL field [<parameter-name>] (<type-length>), location=<location>
Explanation

An application parameter of IDL type F4 or F8 cannot be processed because of exponent over- or underflow. See IDL Data Types.

The additional information <direction>, <parameter-name>, <type-length> and <location> is explained under error message 10010200.

Action

Make sure the IDL file, optionally the SVM file and your server application are consistent. Check your server application for parameter integrity.


10010219 Parameter Error: bad vdata provided. <direction> of IDL field [<parameter-name>] (<type-length>), location=<location>
Explanation

An application parameter of IDL type AV, BV, KV or UV cannot be processed because incorrect data was applied, see Using Variable-length Data Types AV, BV, KV and UV.

The additional information <direction>, <parameter-name>, <type-length> and <location> is explained under error message 10010200.

Action

Make sure the IDL file, optionally the SVM file and your server application are consistent. Check your server application for parameter integrity.


10010220 Parameter Error: bounds exceeds maximum. <direction> of IDL field [<parameter-name>] (<type-length>), location=<location>
Explanation

An index of an application parameter for an IDL unbounded-array (see array-definition under Software AG IDL Grammar) cannot be processed because its value exceeds the maximum for upper bound The additional information <direction>, <parameter-name>, <type-length> and <location> is explained under error message 10010200.

Action

Make sure the IDL file, optionally the SVM file and your server application are consistent. Check your server application for parameter integrity.