EntireX Version 9.7
 —  Administration under Windows  —

Configuring Broker for Internationalization

It is assumed that you have read the document Internationalization with EntireX and are familiar with the various internationalization approaches described there.

This document explains in detail how to configure the broker for the various internationalization approaches, how to write a translation user exit and how to write a SAGTRPC user exit. It covers the following topics:

See also What is the Best Internationalization Approach to use?


Configuring Translation

Start of instruction setTo configure translation

Top of page

Configuring Translation User Exits

Start of instruction setTo configure translation user exits

As a prerequisite, the user-written translation routine DLL must be accessible to the Broker worker threads.

  1. Copy the user-written translation routine DLL into the EntireX bin folder.

  2. In the Broker attribute file, set the service-specific or topic-specific broker attribute TRANSLATION to the name of the user-written translation routine. Example:

    TRANSLATION=MYTRANS

    or

  1. Place the user-written translation routine DLL in a folder of your choice. Spaces in the path name are not allowed.

  2. In the Broker attribute file, set the service-specific or topic-specific broker attribute TRANSLATION to the full path name of the folder of the user-written translation routine. Example:

    TRANSLATION="C:\MyDir\MyTrans\MyTrans.dll"

Top of page

Configuring ICU Conversion

Start of instruction setTo configure ICU conversion

  1. In the Broker attribute file, set the service-specific attribute CONVERSION. Examples:

    We recommend always using SAGTRPC for RPC data streams. Conversion with Multibyte, Double-byte and other Complex Codepages will always be correct, and Conversion with Single-byte Codepages is also efficient because SAGTRPC detects single-byte codepages automatically. See Conversion Details.

  2. Optionally configure a CONVERSION OPTION to tune error behavior to meet your requirements; see OPTION Values for Conversion.

  3. For the Broker attribute, check if ICU conversion is possible, that is, the attribute ICU-CONVERSION is either

Start of instruction setTo configure locale string defaults (optional)

Start of instruction setTo customize mapping of locale strings (optional)

Top of page

Configuring SAGTRPC User Exits

The user-written SAGTRPC user exit DLL must be accessible to the Broker worker threads.

Start of instruction setTo configure SAGTRPC user exits

  1. Copy the user-written SAGTRPC user exit DLL into the EntireX bin folder.

  2. In the Broker attribute file, set the service-specific or topic-specific broker attribute CONVERSION to the name of your SAGTRPC user exit. Example:

    CONVERSION=(MYRPC,TRACE=1)

    or

  1. Place the user-written translation routine DLL in a folder of your choice. Spaces in the path name are not allowed.

  2. In the Broker attribute file, set the service-specific or topic-specific broker attribute CONVERSION to the full path name of the folder of the SAGTRPC user exit. Example:

    CONVERSION="C:\MyDir\MyTrans\MyRpc.dll"

Start of instruction setTo configure locale string defaults

Start of instruction setTo customize mapping of locale strings

Top of page

Writing Translation User Exits

This section covers the following topics:

Introduction

EntireX Broker provides an interface to enable user-written translation routines in the programming language C. It contains three parameters:

Note:
Names for user-written translation routines starting with "SAG" are reserved for Software AG usage and must not be used, e.g. "SAGTCHA" and "SAGTRPC".

Structure of the TRAP Control Block

The C structure TR_TRAP covers the layout of the control block.

typedef struct _TR_TRAP                                     /* I / O */
{
  unsigned long  tr_type;              /* TRAP type: TRAP_TYPE  inp  */
#define TR_TYPE  2                     /* TRAP type ETB 121          */
  long           tr_ilen;              /* Input buffer length   inp  */
  unsigned char *tr_ibuf;              /* Ptr to input buffer   inp  */
  long           tr_olen;              /* Output buffer length  inp  */
  unsigned char *tr_obuf;              /* Ptr to output buffer  inp  */
  long           tr_dlen;              /* Len of data returned: out  */
                                       /* Minimum of tr_ilen         */
                                       /*        and tr_olen         */
  unsigned long  tr_shost;             /* Senders host          inp  */
#define TR_LITTLE_ENDIAN  0            /* little endian              */
#define TR_BIG_ENDIAN     1            /* big endian                 */
  unsigned long  tr_scode;             /* Senders character set inp  */
#define SEBCIBM ((1L << 5)|(1L << 1))  /* 0x22 EBCDIC (IBM)          */
#define SEBCSNI ((1L << 6)|(1L << 1))  /* 0x42 EBCDIC (SNI)          */
#define SA88591            (1L << 7)   /* 0x80 ASCII                 */
  unsigned long  tr_rhost; /* Receivers host     (see tr_shost) inp  */
  unsigned long  tr_rcode; /* Receivers char set (see tr_scode) inp  */
  unsigned long  tr_bhost; /* BROKER host        (see tr_shost) inp  */
  unsigned long  tr_bcode; /* BROKER char set    (see tr_scode) inp  */
  unsigned long  tr_senva; /* Senders ENVIRONMENT field set:    inp  */
#define OFF  0                         /*  ENVIRONMENT field not set */
#define ON   1                         /*  ENVIRONMENT field set     */
  unsigned long  tr_renva; /* Receivers ENVIRONMENT field set:  inp  */
                           /* see tr_senva                           */
#define S_ENV 32           /* size of ENVIRONMENT field              */
  char           tr_senv[S_ENV];/* Senders   ENVIRONMENT field  inp  */
  char           tr_renv[S_ENV];/* Receivers ENVIRONMENT field  inp  */
} TR_TRAP;

The file usrtcha.c is an example of the translation user exit. It is delivered in the Broker user exit directory. See Directories as Used in EntireX.

Using the TRAP Fields

The tr_dlen must be supplied by the user-written translation routine. It tells the Broker the length of the message of the translation. In our example its value is set to the minimum length of the input and output buffer.

All other TRAP fields are supplied by the Broker and must not be modified by the user-written translation routine.

The incoming message is located in a buffer pointed to by tr_ibuf. The length (not to be exceeded) is supplied in tr_ilen. The character set information from the send buffer can be taken from tr_scode.

The outgoing message must be written to the buffer pointed to by tr_obuf. The length of the output buffer is given in the field tr_olen. The character set is specified in tr_rcode. If the addresses given in tr_ibuf and tr_obuf point to the same location, it is not necessary to copy the data from the input buffer to the output buffer.

The environment fields tr_senva and tr_renva are provided to handle site-dependent character set information. For the SEND and/or RECEIVE functions, you can specify data in the ENVIRONMENT field of the Broker ACI control block. This data is translated into the codepage of the platform where EntireX Broker is running (see field tr_bcode) and is available to the tr_senv or tr_renv field in the TRAP control block. tr_senva or tr_renva are set to ON if environmental data is available.

The sample source USRTCHA contains a section to handle the ENVIRONMENT value *NONE. The translation will be skipped if *NONE is supplied by the sender or receiver. Any values given in the API field ENVIRONMENT must correspond to the values handled in the translation routine.

Top of page

Writing SAGTRPC User Exits

This section covers the following topics:

Introduction

EntireX Broker provides an interface to SAGTRPC user exit routines written in the programming language C. The interface contains three parameters:

Note:
Names for conversion routines starting with "SAG" are reserved for Software AG usage and must not be used, e.g. "SAGTCHA" and "SAGTRPC".

Structure of the User Exit Control Block

The C structure UECB shows the layout of the user exit control block.

typedef struct _UECB
{
   unsigned long          eVersion;
#define USRTRPC_VERSION_1                1

   char                *  pInputBuffer;
   unsigned long          uInputLen;
   char                *  pOutputBuffer;
   unsigned long          uOutputLen;
   unsigned long          uReturnedLen;

   unsigned long          shost; 
#define USRTRPC_LITTLE_ENDIAN  0      /* little endian                      */
#define USRTRPC_BIG_ENDIAN     1      /* big endian                         */

   unsigned long          scode;
#define USRTRPC_SEBCIBM ((1L << 5)|(1L << 1)) /* 0x22 EBCDIC (IBM)          */
#define USRTRPC_SEBCSNI ((1L << 6)|(1L << 1)) /* 0x42 EBCDIC (SNI)          */
#define USRTRPC_SA88591            (1L << 7)  /* 0x80 ASCII                 */

   unsigned long          rhost; 
/* see shost */
   unsigned long          rcode;
/* see scode */
   unsigned long          bhost;
/* see shost */
   unsigned long          bcode;
/* see scode */

   unsigned long          uCpSender;
   unsigned long          uCpReceiver;
   unsigned long          uCpBroker;

   char                   eFunction;
#define USRTRPC_FCT_CONVERT             'C'
#define USRTRPC_FCT_GETLENGTH           'L'

   char                   eDirection;
#define USRTRPC_DIR_SENDER_TO_BROKER    '1'
#define USRTRPC_DIR_SENDER_TO_RECEIVER  '2'
#define USRTRPC_DIR_BROKER_TO_RECEIVER  '3'

   char                   sFormat[2];
#define ERX_USERDATA    "01"    /* UserId, Lib, Pgm, etc. from Header 
                                  (truncatable)                         */
#define ERX_METADATA    "02"    /* Header Data (non-truncatable)        */
#define ERX_FRMTDATA    "03"    /* Format Buffer (non-truncatable)      */
#define ERX_SB_ELEMENT  "04"    /* String Buffer                        */
#define ERX_VB_METADATA "05"    /* Value Buffer Array Occurences, 
                                   String Length                        */
#define ERX_PREVIEW     "99"    /* Previewing FB and VB, etc...         */
                                /* Convert data lazy. Do not care on    */
                                /* length changes and truncation.       */
#define ERX_FRMT_A      "A "    /* Data Type A                          */
#define ERX_FRMT_AV     "AV"    /* Data Type AV                         */
#define ERX_FRMT_B      "B "    /* Data Type B                          */
#define ERX_FRMT_BV     "BV"    /* Data Type BV                         */
#define ERX_FRMT_D      "D "    /* Data Type D                          */
#define ERX_FRMT_F4     "F4"    /* Data Type F4                         */
#define ERX_FRMT_F8     "F8"    /* Data Type F8                         */
#define ERX_FRMT_I1     "I1"    /* Data Type I1                         */
#define ERX_FRMT_I2     "I2"    /* Data Type I2                         */
#define ERX_FRMT_I4     "I4"    /* Data Type I4                         */
#define ERX_FRMT_K      "K "    /* Data Type K                          */
#define ERX_FRMT_KV     "KV"    /* Data Type KV                         */
#define ERX_FRMT_L      "L "    /* Data Type L                          */
#define ERX_FRMT_N      "N "    /* Data Type N                          */
#define ERX_FRMT_P      "P "    /* Data Type P                          */
#define ERX_FRMT_T      "T "    /* Data Type T                          */
#define ERX_FRMT_U      "U "    /* Data Type U                          */
#define ERX_FRMT_UV     "UV"    /* Data Type UV                         */

   char                  szErrorText[40];

}  UECB;

The file usrtrpc.c is an example of the SAGTRPC User Exit. It is delivered in the Broker User Exit Directory. See Directories as Used in EntireX.

Using the User Exit Interface Fields

The user exit provides two separate functions, Convert and GetLength. The field eFunction indicates the function to execute.

Errors

Both functions can send an error, using register 15 in the range 1 to 9999 to SAGTRPC together with an error text in the field szErrorText.

Example:

The user exit returns 1 in register 15 and the message "Invalid Function" in szErrorText. The receiver gets the error message 10110001 Invalid Function.

Convert Function

This function has to be executed when the contents of eFunction match the definition USRTRPC_FCT_CONVERT.

uReturnedLen must be supplied by SAGTRPC's user-written conversion exit. Its value must be set to the length of the output buffer.

All other interface fields are supplied by the Broker and must not be modified by SAGTRPC's user-written conversion exit.

The incoming data is located in a buffer pointed to by pInputBuffer. uInputLen defines the length.

The outgoing converted message must be written to the buffer pointed to by pOutputBuffer. The field tr_olen defines the maximum length available.

For variable length data such as AV and KV, an output buffer overflow can occur if the message size increases after conversion or the receiver's receive buffer is too small. In this case error 9999 "output buffer overflow" must be returned, which calls the GetLength Function for the remaining fields.

GetLength Function

The GetLength function evaluates the needed length of the output buffer after conversion. An actual conversion must not be performed. The length needed must be returned in the field uOutputLen.

The GetLength function is called for remaining fields after the Convert function returned the error 9999 "output buffer overflow".

The purpose of this function is to evaluate the length needed by the receiver's receive buffer. This length is returned to the receiver in the ACI field RETURN-LENGTH. The receiver can then use the Broker ACI function RECEIVE with the option LAST together with a receive buffer large enough to reread the message.

Character Set and Codepage

The character-set information used is the same as in the user-written translation routine and is taken from scode (for the sender), rcode (for the receiver) and bcode (for the Broker). The character-set information depends on the direction information given in the field eDirection. See the following table:

eDirection From Character Set To Character Set
USRTRPC_DIR_SENDER_TO_BROKER scode bcode
USRTRPC_DIR_SENDER_TO_RECEIVER scode rcode
USRTRPC_DIR_BROKER_TO_RECEIVER bcode rcode

Alternatively, the codepage as derived from the locale string mapping process is provided in uCpSender (sender codepage), uCpReceiver (receiver codepage) and uCpBroker (Broker codepage), and can be used to find the correct conversion table. See the following table and also Locale String Mapping.

eDirection From Codepage To Codepage
USRTRPC_DIR_SENDER_TO_BROKER uCpSender uCpBroker
USRTRPC_DIR_SENDER_TO_RECEIVER uCpSender uCpReceiver
USRTRPC_DIR_BROKER_TO_RECEIVER uCpBroker uCpReceiver

Software AG IDL Data Types to Convert

The field sFormat provides the SAGTRPC user-written conversion exit with the information on the IDL data types to convert. Each data type can be handled independently.

sFormat Data to be converted Notes
FMTA IDL data type A 1, 3, 4
FMTAV IDL data type AV 4, 5
FMTB IDL data type B 1, 2, 7
FMTBV IDL data type BV 1, 2, 7
FMTD IDL data type D 1, 2, 7
FMTF4 IDL data type F4 1, 2, 7
FMTF8 IDL data type F8 1, 2, 7
FMTI1 IDL data type I1 1, 2, 7
FMTI2 IDL data type I2 1, 2, 7
FMTI4 IDL data type I4 1, 2, 7
FMTK IDL data type K 1, 3, 4
FMTKV IDL data type KV 4, 5
FMTL IDL data type L 1, 2, 7
FMTN IDL data type N 1, 2, 7
FMTP IDL data type P 1, 2, 7
FMTT IDL data type T 1, 2, 8
FMTU IDL data type U 1, 2, 7
FMTUV IDL data type UV 1, 2, 7
FMTUSER RPC user data such as user ID, library, program... 1, 3, 4
FMTMETA RPC metadata 1, 2, 7
FMTFB RPC format buffer 1, 2, 7
FMTSB RPC metadata variable length 4, 5, 7
FMTPRE Preview data 4, 6, 7

Notes:

  1. Field length is constant.
  2. The field content length must not increase or decrease during conversion. If this happens, the user exit should produce an error.
  3. If the field content length decreases during the conversion, suitable padding characters (normally blanks) have to be used.
    If the field content length increases during conversion and exceeds the field length, the contents must be truncated or, alternatively, the conversion can be aborted and an error produced.
  4. If the contents are truncated, character boundaries are the responsibility of the user exit. Complete valid characters after conversion have to be guaranteed. This may be a complex task for codepages described under Conversion with Multibyte, Double-byte and other Complex Codepages. For Conversion with Single-byte Codepages it is simple because the character boundaries are the same as the byte boundaries.
  5. The field length can decrease or increase during the conversion up to the output buffer length. The new field length must be returned in uReturnedLen. If the output buffer in the Convert function is too small, error 9999 must be returned to the caller.
  6. The field buffer should continue to be converted until the output buffer is full or the input buffer has been processed. If the field content length increases or truncations occur, no error should be produced. If the field content length decreases, there should be no padding. The new field length should simply be returned to the caller.
  7. Codepages used for RPC data streams must meet several requirements. See Codepage Requirements for RPC Data Stream Conversions. If these are not met, the codepage cannot be used to convert RPC data streams.

Start of instruction setTo compile and link the SAGTRPC User Exit

Top of page

Building and Installing ICU Custom Converters

User-written ICU custom-converters can be used for ACI-based Programming, RPC-based Components, and Reliable RPC.

This section covers the following topics:

Writing a User-written ICU Converter

ICU uses algorithmic conversion, non-algorithmic conversion and combinations of both. See ICU Conversion. Non-algorithmic converters defined by the UCM format are the easiest way to define user-written ICU converters. See UCM Format.

Start of instruction setTo write a (non-algorithmic) user-written ICU converter

Writing algorithmic and partially algorithmic converters can be complex. However, they can be installed into EntireX in the same way as the table-driven, non-algorithmic ones. A description of how to write algorithmic and partially algorithmic converters is beyond the scope of this documentation; please see the ICU documentation and other sources specified under ICU Resources.

Compiling a User-written ICU Converter

Start of instruction setTo compile the user-written ICU converter

Installing a User-written ICU Converter

Start of instruction setTo install the user-written ICU converter

  1. Check if the folder Software AG exists in the Windows local application data directory for all users. See Application Data Directory. If not, create the folder Software AG. Example:

    C:\Documents and Settings\All Users\Application Data\Software AG
  2. Check if the folder icudt<icu-version>l exists in the folder Software AG (see 1 above) in the Windows application data folder for all users. If not, create the folder icudt<icu-version>l where:

    C:\Documents and Settings\All Users\Application Data\Software AG/icudt32l

    Notes:

    1. The folder and its naming are given by ICU standard. It is not invented by Software AG.
    2. See the Release Notes to determine the ICU version used by the broker you are running and form the correct folder name - otherwise the user-written ICU converter will not be located.
    3. There are also other approaches supported by ICU to locate converters. These approaches are (also) ICU version dependent. However, Software AG recommends the mechanism described above. See the ICU website for more information under ICU Resources.
  3. If the converter name is not sent as the locale string by your application, customize the mapping of locale strings by assigning the user-written ICU converter (codepage) to locale strings in the Broker attribute file, see locale-string for how to customize the mapping of locale strings to codepages. Example:

    DEFAULTS=CODEPAGE 
    /* Customer-written ICU converter */
    CP1140=myebcdic
    CP0819=myascii
  4. For the Broker attribute, check whether ICU conversion is possible, that is, the attribute ICU-CONVERSION is

  5. For the Broker attribute, check whether use of ICU custom converters is possible, that is, the attribute ICU-SET-DATA-DIRECTORY is either

Top of page