This class indicates errors returned from the SAGTRPC user exit. This class represents errors which can be defined by the developer of the SAGTRPC user exit. The errors documented here occur in the delivered SAGTRPC user exit example and it is not recommended to change the meaning of the errors in your own implementation of the SAGTRPC user exit. The meaning of the error 10119999 must not be changed because the broker checks for it. If you change the meaning of the errors, refer to your implementation of the SAGTRPC user exit. Messages of this class have the format:

1011nnnn

where 1011 is the message class, and
nnnn is the message number in the range 0000 - 9999.

Overview of Messages

10110001 | 10110002 | 10110003 | 10110004 | 10110005 | 10110006 | 1010007 | 10110008 | 10110009 | 10119999

10110001 Invalid Function
Explanation

The function code passed from EntireX to the SAGTRPC user exit is invalid.

Action

If you not have changed the original meaning of the error message, contact Software AG. Otherwise check your SAGTRPC user exit.


10110002 Unsupported Function
Explanation

The function code passed from EntireX to the SAGTRPC user exit is not supported by your SAGTRPC user exit.

Action

If you not have changed the original meaning of the error message, contact Software AG. Otherwise check your SAGTRPC user exit.


10110003 Invalid Direction
Explanation

The direction indicator passed from EntireX to the SAGTRPC user exit is invalid.

Action

If you not have changed the original meaning of the error message, contact Software AG. Otherwise check your SAGTRPC user exit.


10110004 Invalid Length
Explanation

The length of the input buffer is invalid (zero).

Action

If you not have changed the original meaning of the error message, contact Software AG. Otherwise check your SAGTRPC user exit.


10110005 Codepage not supported
Explanation

The codepage passed from EntireX to the SAGTRPC user exit is not supported.

Action

If you have not changed the original meaning of the error message, contact Software AG. Otherwise check your SAGTRPC user exit.


10110006 UECB missing
Explanation

The user exit control block passed to the SAGTRPC user exit is missing.

Action

If you not have changed the original meaning of the error message, contact Software AG. Otherwise check your SAGTRPC user exit.


1010007 Invalid InputBuffer
Explanation

The input buffer passed to the SAGTRPC user exit is missing.

Action

If you not have changed the original meaning of the error message, contact Software AG. Otherwise check your SAGTRPC user exit.


10110008 Invalid OutputBuffer
Explanation

If you not have changed the original meaning of the error message, contact Software AG. Otherwise check your SAGTRPC user exit.

Action

Contact Software AG support.


10110009 No Codepages defined
Explanation

There are no codepages defined within the SAGTRPC user exit.

Action

If you have not changed the original meaning of the error message, contact Software AG. Otherwise check your SAGTRPC user exit.


10119999 Output Buffer overflow
Explanation

This SAGTRPC user exit error signals an overflow of the output buffer during conversion from the SAGTRPC user exit to the broker. The meaning of this error must not be changed because the broker checks for it and, for the receiving application, tries to reread the payload with broker function RECEIVE,OP=LAST.

Action

None.