ADAL01 CLOG not active
Explanation

The command log is sequential, and the DDLOG data set was either set to "dummy" or could not be opened. Command logging is switched off.


ADAL02 CLOGRn is active
Explanation

The specified command log for dual or multiple command logging is now active.


ADAL03 Command log DDCLOGRn has started
Explanation

Command logging has switched to data set DD/CLOGRn .


ADAL04 Warning : now it is too late to copy DDCLOGRn
Explanation

The specified dual or multiple command logging data set is being overwritten with new log data, and is no longer valid .


ADAL05 I/O error on DDCLOGRn. Command logging terminated
Explanation

Command logging to data set DDCLOGRn was terminated by an I/O error .


ADAL06 Command log is not available
Explanation

None of the dual or multiple command logging data sets was available (presently being copied by ADARES) . Command logging is switched off.


ADAL07 Command long could not be opened
Explanation

An invalid command logging device or size was specified, or an I/O error on either the first or last block was detected. Command logging is switched off.


ADAL10 PPT error nn processing CLOG
Explanation

An error occurred while processing the parallel participant table (PPT). The nucleus stays up, but command logging is disabled.

Action

Collect diagnostic information such as that provided by the ADAICKPPTPRINT function. Provide the error number "nn" and the PPTPRINT to your Software AG technical support representative. It may be necessary to format the PPT and restart the nuclei in order to rebuild the PPT.


ADAL11 Warning - CLOG datasets have changed. PPT overwritten.
Use ADARES MERGE CLOG to copy previous CLOG datasets.
Explanation

Either the CLOG data sets are different from what was specified in the last session or no CLOGs are specified but the previous CLOGs were not copied. The PPT information about these data sets is being overwritten.

Action

If the contents of the CLOGs are still needed, they must be copied with the CLCOPY function and then merged manually. If the contents are not needed, no action is required.


ADAL12 date time CLOGMRG=YES not valid. CLOGMRG not in effect.
Explanation

This message is generated if an attempt is made to initialize a non-plex/ASM nucleus (NUCID=0) with CLOGMRG=YES specified. This is an informational message only and the nucleus will come up. CLOGMRG=YES should only be specified if NUCID is greater than 0.

Action

No action is required for this informational message.