ADAM001 | ADAM002 | ADAM003 | ADAM004 | ADAM005 | ADAM006 | ADAM007 | ADAM008 | ADAM009 | ADAM01 | ADAM010 | ADAM011 | ADAM012 | ADAM013 | ADAM014 | ADAM015 | ADAM016 | ADAM017 | ADAM018 | ADAM019 | ADAM020 | ADAM021 | ADAM022 | ADAM025I | ADAM13 | ADAM14 | ADAM15 | ADAM16 | ADAM17 | ADAM18 | ADAM19 | ADAM20 | ADAM76 | ADAM77 | ADAM78 | ADAM79 | ADAM81 | ADAM82 | ADAM83 | ADAM85 | ADAM86 | ADAM88 | ADAM89 | ADAM8B | ADAM8C | ADAM90 | ADAM91 | ADAM92 | ADAM93 | ADAM94 | ADAM96 | ADAM97 | ADAM98 | ADAM99
ADAM001 | VM/System product release level under 3 - not supported |
Explanation |
The z/VM version being used is not supported by the Entire Net-Work IUCV driver. The IUCV line driver cannot be opened. |
Action: |
Upgrade the system to the required z/VM level. |
ADAM002 | Line driver maximum number of connections exceeded on type machine |
Explanation |
z/VM systems only: An IUCV connection between two virtual machines could not be made because either the initiating (source) or target virtual machine exceeded the MAXCON value in the machine's CP directory. The type of machine (SOURCE or TARGE) that exceeded the MAXCON value is given in the message. |
Action |
Increase the appropriate MAXCON value and update the machine's CP directory. |
ADAM003 | No IUCV authorization found |
Explanation |
Entire Net-Work was not able to sign on to IUCV because the virtual machine was not IUCV-authorized in the CP directory. The IUCV line driver cannot be opened. |
Action: |
Add the required IUCV statements to the CP directory for the virtual machine. |
ADAM004 | No IUCV message found on link link-name |
Explanation |
The Entire Net-Work IUCV line driver attempted to receive or reply to a message that was not found in any IUCV message queue. The IUCV line terminates Entire Net-Work abnormally. |
Action: |
Make note of the link "link-name", any related messages and dump listings, and call your Software AG technical support for assistance. |
ADAM005 | IUCV function function error err-num on link link-name on path-ID path |
Explanation |
The specified function detected error err-num on the specified link and path. This message is followed by message ADAM007. The IUCV line terminates Entire Net-Work abnormally. |
Action: |
Note the error number (err-num), the link (link-name) and any related messages, and call your Software AG technical support for assistance. |
ADAM006 | IUCV send completion error err-num onlink link-name path-ID path |
Explanation |
The IUCV SEND function detected error err-num on the specified link and path. The IUCV line terminates Entire Net-Work abnormally. |
Action: |
Note the error number (err-num), the link (link-name), any related messages, and call your Software AG technical support for assistance. |
ADAM007 | IUCV parameter block at location location |
Explanation |
This message occurs after an ADAM005 error, and is followed by a hexadecimal display of the failing IUCV parameter block. The IUCV line terminates Entire Net-Work abnormally. |
Action: |
Retain the displayed information plus any other related error or dump information and contact your Entire Net-Work technical support representative. |
ADAM008 | Incoming traffic impaired on link link-name due to buffer shortage |
Explanation |
Incoming messages on link link-name are being delayed due to insufficient buffer space. Entire Net-Work suspends incoming data traffic until the buffer shortage is resolved. |
Action: |
Increase the short-term buffer size for a virtual machine running a non-paging guest operating system, or increase the page-fixed buffer size for a paging guest system virtual machine. Both buffers are controlled by the NODE statement parameters for the link-name's node. |
ADAM009 | Communications impaired to link link-name |
Explanation |
Communication with the specified link is impaired by insufficient buffer space on that node. Message ADAM008 occurs on that node, advising of the problem. The adjacent Entire Net-Work node suspends incoming data traffic until the buffer shortage is resolved. |
Action: |
Increase the short-term buffer size for a virtual machine running a non-paging guest operating system on the specified node, or increase the page-fixed buffer size for a paging guest system virtual machine. Both buffers are controlled by the NODE statement parameters for the link-name's node. |
ADAM01 | version job-name abend code code | ||||||
Explanation |
z/VSE systems only : An ADAMAF abend occurred. The variable message information is as follows:
|
ADAM010 | Pending connection rejected due to buffer shortage |
Explanation |
This node could not accept a connection due to inadequate buffer space. The IUCV path which was initiated is not connected. |
Action: |
Increase the short-term buffer size for a virtual machine running a non-paging guest operating system, or increase the page-fixed buffer size for a paging guest system virtual machine. Both buffers are controlled by the NODE statement parameters for the specified node. |
ADAM011 | Normal communications resumed to link link-name |
Explanation |
This informational message advises that the condition causing previous impaired communications has been corrected. A buffer shortage indicated by a message ADAM008 or ADAM009 has been resolved. |
Action: |
No action required. This message is for your information only. |
ADAM012 | Buffer program check on link link-name |
Explanation |
A program check occurred while accessing an IUCV buffer area. Entire Net-Work terminates operation with a dump. |
Action: |
Note the link "link-name", any related error or dump listing information, and call your Software AG technical support for assistance. |
ADAM013 | number number of sends 2way count-a 1way count-b |
Explanation |
This normal termination message specifies the total number of SEND/REPLY (SEND 2WAY) and SEND 1WAY messages, as well as the counts of each type of SEND. Entire Net-Work proceeds to terminate normally. |
Action: |
No action required. This message is for your information only. An excessive number of SEND 1WAYs maybe an indicator that the MSGLIM parameter value is insufficient. |
ADAM014 | number number of replies non-null count-a null count-b |
Explanation |
This normal termination message specifies the total number of IUCV replies as well as the counts of replies containing data (non-null) and those without data (null). Entire Net-Work proceeds to terminate normally. |
Action |
No action required. This message is for your information only. An excessive number of null replies indicates the SEND 1WAY protocol is more suitable. |
ADAM015 | Incoming message exceeds buffer length on link link-name |
Explanation |
An incoming IUCV message from the link link-name was too long for the available buffer. Entire Net-Work terminates operation with a dump. |
Action: |
Increase the short-term buffer pool size (specified by the NODE statement for the specified node ID). |
ADAM016 | Outgoing message exceeds buffer length on link link-name |
Explanation |
An outgoing IUCV message was too large for the allocated buffer space. Entire Net-Work terminates operation on this node with a dump. |
Action: |
Increase the short-term buffer pool size (specified by the NODE statement for this node ID). |
ADAM017 | Connection to user user-id denied due to block length conflict |
Explanation |
The values specified by this node's and the partner node user-id's LINK statement MAXBLK parameters are not the same. The IUCV path that was initiated is not connected. |
Action: |
Correct one of the LINK statement's MAXBLK values to agree with the other. |
ADAM018 | Message limit on path to VMID vm-id INSUFFICIENT |
Explanation |
The maximum number of outstanding IUCV messages allowed was exceeded. The IUCV line terminates abnormally. |
Action: |
Correct either the IUCV LINK statement's MSGLIM parameter value, or the CP directory MSGLIMIT value. |
ADAM019 | Maximum block length set to length |
Explanation |
Entire Net-Work found no MAXBLK value on the IUCV LINK statement in a paging system where a maximum block size is required. Entire Net-Work sets the block length to the page size "length". |
Action |
No action is required for this informational message. |
ADAM020 | Initialization error err-num for guest system IUCV support |
Explanation |
Entire Net-Work was unable to initialize the IUCV line driver in the guest operating system. The driver is not opened. If the IUCV driver is the only driver specified, Entire Net-Work terminates operation on this node. |
Action: |
Note the error number ("err-num") and guest operating system level, and call your Software AG technical support for assistance. |
ADAM021 | Link link-name not connected error err-code IUCV-code code | ||||||||
Explanation |
A connection could not be made to another virtual machine. The error code "err-code" is returned by the operating system's IUCV interface; the IUCV code "code" is returned in the IPRCODE field of the IUCV parameter block. The value "code" can be one of the following IUCV CONNECT error codes:
IUCV codes 11 and 12 are two of the most common codes that can occur. |
||||||||
Action: |
Ensure that the virtual machine at the other end of the link is logged on, active, and authorized to use IUCV. Refer to the appropriate operating system information for the meaning of "err-code", and the corrective action. For detailed IUCV and related code information, see IBM's z/VM System Programmer's Guide and z/VM System Facilities for Programming manuals. |
ADAM022 | Path to VMID vm-id disconnected due to interrupt queue shortage |
Explanation |
The Entire Net-Work IUCV support routine was not able to save the status of an incoming IUCV interruption due to a lack of interrupt queue elements. The IUCV link is disconnected. |
Action: |
Increase the value of the QSIZE parameter for NETSIR and rerun NETSIP with the REPLACE parameter |
ADAM025I | IUCV driver manually closed |
Explanation |
The IUCV driver has been closed either by an operator command or by SHUTDOWN processing. |
Action |
No action is required for this informational message. |
ADAM13 | number number of sends 2way count-a 1way count-b |
Explanation |
This normal termination message specifies the total number of SEND/REPLY (SEND2WAY) and SEND1WAY messages, as well as the counts of each type of SEND. |
ADAM14 | number bynber if replies non-null count-a null count-b |
Explanation |
This normal termination message specifies the total number of IUCV replies as well as the counts of replies containing data (non-null) and those without data (null). |
ADAM15 | Incoming message exceeds buffer length on link link-id |
Explanation |
An incoming IUCV message from the specified link exceeded the length of the available buffer. Entire Net-Work terminates with a dump. |
Action: |
Use the message blocking and/or compression options for the link (specified by the IUCV LINK statement), or increase the short-term buffer pool size (specified by the NODE statement for the specified node ID). |
ADAM16 | Outgoing message exceeds buffer length on link link-id |
Explanation |
An outgoing IUCV message was too large for the allocated buffer space. Entire Net-Work terminates operation on this node with a dump. |
Action: |
Use the message blocking and/or compression options for the specified link (specified by the IUCV LINK statement), or increase the short-term buffer pool size (specified by the NODE statement for this node ID). |
ADAM17 | Connection to user user-id denied due to block length conflict |
Explanation |
The values specified by this node's and the partner node "user-id's" LINK statement MAXBLK parameters are not the same. |
Action: |
Correct one of the LINK statement's MAXBLK values to agree with the other. |
ADAM18 | Message limit on path to VMID vm-id insufficient |
Explanation |
The maximum number of outstanding IUCV messages allowed was exceeded. |
Action: |
Correct either the IUCV LINK statement's MSGLIM parameter value, or the CP directory OPTION MAXCONN value. |
ADAM19 | Maximjm block length set to length |
Explanation |
Entire Net-Work found no MAXBLK value on the IUCV LINK statement, and therefore has set the block length to the page size length. |
ADAM20 | Initialization error err-num for guest system IUCV support |
Explanation |
Entire Net-Work was unable to initialize the IUCV line driver in the guest operating system. The driver is not opened. If the IUCV driver is the only driver specified, Entire Net-Work terminates operation on this node. |
Action: |
Note the error number ("err-num") and guest operating system level, and call your Software AG technical support for assistance. |
ADAM76 | SVCDUMP busy |
Explanation |
A request to write an SVC dump has failed due to a busy condition. This indicatest that the system service is active processing another SVC dump request. If the busy condition is returned from the first attempt to write to SVCDUMP. the following message is issued: ADAM76 SVCDUMP busy - retry ever 05 sec for 15 min In this case, the SVC dump requrest will be retried as indicated in the message. If the busy condition persists for the maximum time permitted, the following messages are issued and no further retries are attempted: ADAM76 SVCDUMP busy - dump not written ADAM78 SVCDUMP SDUMP FAILED RC rc/sc Dump processing then continues as if the SVCDUMP DD statement had not been specified. |
Action |
No action is required for this informational message. |
ADAM77 | SVCDUMP ignored - not authorized |
Explanation |
An SVC dump ( Dump processing continues as if the SVCDUMP DD statement had not been specified. |
Action |
No action is required for this information message. |
ADAM78 | SVCDUMP {SDUMP|TDUMP} failed RC rc/rsn |
Explanation |
The SVC dump failed. The return code (rc) and reason code (rsn) from the IBM SDUMP macro or IBM IEATDUMP macro are given in the message. |
Action |
No action is required for this information message. |
ADAM79 | SVCDUMP {SDUMP|TDUMP} written RC rc/rsn |
Explanation |
The SVC dump was written. The return code (rc) and reason code (rsn) from the IBM SDUMP macro or IBM IEATDUMP macro are given in the message or are suppressed if the return code is zero. |
Action |
No action is required for this information message. |
ADAM81 | dbid unexpected return code ret-code information infunction | ||||||||||||||
Explanation |
BS2000 systems only: The BS2000 macro or function function issued the unexpected return code ret-code. Depending on the specified macro or function, information contains more error-specific information:
|
||||||||||||||
Action: |
For the ENAMP function, if ret-code is 08...00, a common memory pool is already present and a new pool is being required. An attempt was most likely made to bring up an active nucleus again. Do not bring up the same nucleus twice for the same task if the ENAMP function was indicated. The MP2LEVEL indication occurs when an incompatible reentrant router was loaded by another Adabas nucleus. Refer to the related BS2000 information for return code meanings and actions. |
ADAM82 | dbid Adabas cancelled in bourse wait |
Explanation |
BS2000 systems only: The Adabas nucleus was cancelled while waiting for an event. The nucleus terminates without giving control to termination recovery to reset the the DIB block. The user abend code is 233. |
ADAM83 | dbid text |
Explanation |
BS2000 systems only: The message text is explained as follows: New IDT created,name=idt-name,GROUPS={YES | NO} The reporting task created a new ID table idt-name located above the 16-MB limit with the attribute GROUPS=NO (global to the machine) or GROUPS=YES (in the scope of the user logon). Connected to IDT idt-name,GROUPS={YES | NO} The reporting task participates in the existing ID table idt-name located above the 16-MB limit with the attribute GROUPS=NO (global to the machine) or GROUPS=YES (in the scope of the user logon). CMDQ/AB pool enabled, LOC=loc The location of the command queue (CMDQ) pool is location loc" which is either "above" or "below". Disconnected from IDT idt-name The nucleus closed out its use of ID table idt-name. Another nucleus or user task is holding the ID table. Disconnected from CMDQ/AB pool The nucleus stopped processing, but the command queue (CMDQ) pool is still being held by a user task. IDT disabled, Name=idt-name CMDQ/AB pool disabled The nucleus stopped processing, and no user task is using the command queue, which is removed from the system. |
ADAM85 | dbid IDT INIT error : text |
Explanation |
BS2000 systems only: An error occurred during the initialization of the IDT. Depending on the message text, the explanations are as follows: ADARER is no BS2000 router The load library does not contain a consistent router module (ADARER). Wrong ADARER version vv expected: ee The load library contains a router module (ADARER) from an earlier Adabas version where vv is the version level encountered and ee is the version level required. RERPROG NE "RERBS2" NOT AN XS ROUTER NOT AN SMP ROUTER ROUTER NOT AT OFFSET 0 A module containing the Adabas router (ADARER) was loaded, but it is not an SSF router of the required version. |
Action: |
Check the contents of the load library(s). Check load library assignments. |
ADAM86 | dbid IDT CONN error : text |
Explanation |
BS2000 systems only: An error occurred during connection to an existing IDT. Depending on the message text, the explanations are as follows: ADARER is no BS2000 router The IDT does not contain a consistent router module (ADARER). IDTNAME= specifies a memory pool other than an Adabas IDT. Wrong ADARER version The IDT contains a router module (ADARER) from an earlier Adabas version. |
Action: |
Check IDTNAME= parameters. Note that the first target coming up and initializing the IDT must have the latest Adabas version. |
ADAM86 | dbid IDT CONN ERROR : text 1) SMPSVC (ROUTER EXTENSION) NOT LOADED 1) DBID ALREADY IN USE BY SMP CLUSTER 2) |
Explanation |
BS2000 systems only: An error occurred when attempting to connect to the IDT. A memory pool named by IDTNAME was found, but did not contain the expected structure. The message text is explained as follows: RERPROG NE "RERBS2" The ADARER program encountered was not the required RERBS2. Router ID was xxxx,expected yyyy The router ID encountered (xxxx) was not the router ID required (yyyy). RERAIDT = ZERO IDIDTID = WRONG VALUE NOT AN SMP ROUTER This message can occur when an Adabas nucleus of version 6.1.3 or above attempts to connect to a non-SMP router; that is, one that contains modules from Adabas version 6.1.2 or below. |
Action: |
Determine whether:
|
ADAM88 | ddddd Processor(s) = n |
Explanation |
BS2000 systems only. This is an information message which states how many processors (n) are available on the computer on which the database ddddd is started. |
Action: |
None required. |
ADAM89 | dbid Unexpected return code ret-code from SSF function (function) |
Explanation |
BS2000 systems only: The specified SSF function encountered an unrecoverable condition. |
Action: |
Contact your Software AG technical support representative. |
ADAM8B | dbidIDT Version vv date yyyymmdd SM ssss |
Explanation |
BS2000 systems only: This informational message identifies which IDT version (vv) is being accessed by the database (dbid) when started, its date of assembly (yyyymmdd) and the SM level (ssss). |
Action: |
No action is required for this informational message. |
ADAM8C | dbid Router Zaps Applied: zzzz zzzz zzzz zzzz zzzz zzzz zzzz |
Explanation |
BS2000 systems only: This informational message identifies which zaps (zzzz) have been applied to the IDT accessed by the database (dbid) when started. |
Action: |
No action is required for this informational message. |
ADAM90 | dbid Adabas subtask abend code code PSW password reg0 reg1 reg2 reg3 (R0-R3) reg4 reg5 reg6 reg7 (R4-R7) reg8 reg9 reg10 reg11 (R8-RB) reg12 reg13 reg14 reg15 (RC-RF) |
Explanation |
An Adabas subtask abend occurred. The abend code, password, and register information is in the same foramt as the ADAM99 message. The subtask terminates with Adabas user abend 252. |
ADAM90 | dbid Post module ADAAPSPE loaded |
Explanation |
BS2000 systems only. This isn't informational message. It states that the Software AG internal product software (APS) posting module ADAAPSPE has been loaded into the router. This is an acknowledgment that access to APS applications is now enabled. |
ADAM91 | dbid target user gone job job-name user ID hex-user-id |
Explanation |
Adabas tried to process a user call, but the addressed data area was not addressable, or no longer contained recognizable data. This message occurred while Adabas was receiving the command (router 08-CALL processing). The program was apparently cancelled after issuing an Adabas command (router 04-CALL), perhaps due to a communication delay or timeout. |
Action: |
Avoid ending, abending, or cancelling the program, if possible. |
ADAM92 | dbid target user gone job job-name user ID hex-user-id |
Explanation |
Adabas tried to process a user call, but the addressed data area was not addressable, or no longer contained recognizable data. This message occurred while Adabas was posting the user after command completion (router 12-CALL processing). The program was apparently cancelled after issuing an Adabas command (router 04-CALL), perhaps due to a communication delay or timeout. |
Action: |
Avoid ending, abending, or cancelling the program, if possible. |
ADAM92 | ddddd Post module ADAAPSPE loaded |
Explanation |
BS2000 systems only. This is an information message. This states that the Software AG internal product software (APS) posting module ADAAPSPE has been loaded into the router. This is an acknowledgement that access to APS applications is now enabled. |
Action: |
Avoid ending, abending, or cancelling the program, if possible. |
ADAM93 | dbid target User gone job job-name user ID hex-user-id |
Explanation |
The user's program exceeded the ADARUN CT time allowed without receiving the results of an Adabas call (performing router 16-CALL processing). This could be caused by processing delays caused by an overloaded system or network, low priority, or teleprocessing delays. Adabas assumes that the user program has been cancelled; Adabas frees the command queue element (CQE) and alternate buffers. If a user program eventually issues a router 16-CALL, a response code 254 also occurs. |
Action: |
Consider increasing the ADARUN CT time, or otherwise increase the resources for the user program. Avoid cancelling or ending the user program, if this was done. |
ADAM94 | dddd Post Module ADAASPE loaded |
Explanation |
BS2000 systems only. This is an information message stating that the Software AG internal product software (APS) posting module ADAAPSPE has been loaded into the router. This is an acknowledgment that access to APS applications is now enabled. |
Action |
No action required for this informational message. |
ADAM96 | dbid MPM running in XAE-mode-type mode under Vv dbid MPM running in ops - mode-type mode under level |
||||||||
Explanation |
This message specifies the mode under which Adabas is running:
|
ADAM97 | dbid MVS has set this service's ASCB/ASID unusable until the next IPL initiator must be restarted |
Explanation |
ASIDs are defined by cross-memory services. For more information regarding the use of ASCB/ASIDs by Adabas, refer to the Adabas Installation documentation section Requirements for Cross-Memory Services. |
Action: |
Ask the system operator to start the initiator. |
ADAM97 | dbid This ASCB/initiator will be terminated by MVS at EOJ |
Explanation |
When a nucleus with an active cross-memory environment ends, the entire address space including any initiator is also terminated, whether termination is normal or not. Refer to the Adabas Installation documentation section Requirements for Cross-Memory Services . |
Action: |
None required. This information is for your information only. |
ADAM98 | dbid Target initialization error: cause | ||||||||||||||||||||||||||||||
Explanation |
ADAMPM was unable to establish interregion communication for the reason specified in the message (cause), which is one of the following:
|
ADAM99 | dbid ADABAS ABEND CODE code error-environment-information |
Explanation |
The nucleus ended abnormally. This is the result of an error detected by Adabas (user abend code) or by the operating system (system abend code). All abend code values are given in hexadecimal notation. The abend code (code) format is specific to your operating system:
Additional error environment information follows the abend code in the message text, in the following order:
The following is an example of an ADAM99 message produced when a z/OS nucleus was canceled: ADAM99 00226 ADABAS Abend code 40222000 00000000 078D1000 8001EC02 00020001 00000000 (PSW, EC Info) 00000000_00000001 00000000_FFFBC5F8 (R0-R1) 00000000_00043A08 00000000_001651A0 (R2-R3) 00000000_00000000 00000000_00009C9A (R4-R5) 00000000_246FA940 00000000_0014D6EC (R6-R7) 00000000_0014D6EC 00000000_0005A988 (R8-R9) 00000000_0001EBA8 00000000_00056000 (R10-R11) 00000000_800109E0 00000000_000129D0 (R12-R13) 00000000_8001EBD4 00000000_808D6C68 (R14-R15) 00000000 00000000 00000000 00000000 (AR0-AR3) 00000000 00000000 00000000 00000000 (AR4-AR7) 00000000 00000000 00000000 00000000 (AR8-AR11) 00000000 00000000 00000000 00000000 (AR12-AR15) ADARUN 00007A60 ADALNK 800456C0 ADAMOD 80044100 ADAMIM 80054000 ADARVU 8004CEB8 ADACLX 80051000 ADARMT 80053100 ADAMSG 8004A000 ADAIOR 800109E0 ADAIOS 80015A18 ADANC0 00055000 ADANC1 0005A800 ADANC2 00068000 ADANC3 0008C400 ADANC4 000A0800 ADANC5 000B4400 ADANC6 000C7800 ADANC7 000DBC00 ADANC8 000F4400 ADANC9 0010B000 ADANCA 00113400 ADANCB 00123000 ADANCC 00127D00 ADALOG 00135998 ADAMPM 8013C430 ADARAC 8013FF30 ADAMGR 801464F8 ADAMGI 8014AF00 |
Action: |
Refer to your Adabas documentation for a description of a nucleus user abend, or to the appropriate operating system documentation for a description of the system abend. |