The following messages may appear when errors occur in the Adabas CICS and BS2000 TP monitor interface operations.
When CICS is started, the Adabas TP monitor component displays several informational or error messages on the system console. These often contain the addresses of key Adabas and CICS control blocks which are useful in problem determination.
Be sure that the console messages indicate that the Adabas TRUE environment has been properly established.
If an error message is produced, note the CICS EIBRESP, EIBRESP2, and EIBRCODE, which is displayed.
Note any Adabas response code (ACBRSP) displayed by the TP monitor program at CICS startup.
ADAK01 | ADAK02 | ADAK03 | ADAK04 | ADAK040 | ADAK041 | ADAK042 | ADAK043 | ADAK044 | ADAK045 | ADAK046 | ADAK047 | ADAK048 | ADAK049 | ADAK05 | ADAK050 | ADAK051 | ADAK052 | ADAK053 | ADAK054 | ADAK055 | ADAK056 | ADAK057 | ADAK058 | ADAK059 | ADAK06 | ADAK061 | ADAK062 | ADAK063 | ADAK064 | ADAK065 | ADAK066 | ADAK067 | ADAK068 | ADAK069 | ADAK07 | ADAK070 | ADAK071 | ADAK072 | ADAK073 | ADAK074 | ADAK08 | ADAK09 | ADAK10 | ADAK73
ADAK01 | dbid Unexpected return code ret-code in function | ||||||||||||||
Explanation |
During BS2000 TP monitor interface operations, the return code (ret-code) given in the message occurred in one of the following functions and for the specified reason:
|
||||||||||||||
Action |
See the BS2000 Executive Macro documentation for an explanation of "ret-code". |
ADAK02 | Types of LOADLIB for ADALNK (adalink) and ADARER mismatch |
Explanation |
During BS2000 TP monitor interface operations, one module was loaded from an XS library and the other from an NXS library. NXS and XS components cannot be mixed. This message is accompanied by the ADAK01 message. The adalink field of this message has the
format
If yy is less than xx, the IDT common memory where the ADARER is loaded has been created by and loaded from an older Adabas version. For example, if xx=83 and yy=81, an Adabas 61x ADALNK is using an Adabas 53x ADARER. |
Action |
Check the Adabas library versions of the databases that are using the IDTNAME (the default is ADABAS5F) of your ADALNK. Either upgrade databases using older Adabas libraries to the new version, or use different IDTNAMEs for different Adabas versions. |
ADAK03 | Parameter error |
Explanation |
During BS2000 TP monitor interface operations, the Adalink parameter service detected a syntax error. |
Action |
Correct the syntax and rerun. |
ADAK04 | The following ADALNK (adalink) are used for this run |
Explanation |
This is the header of the Adalink parameter listing used during BS2000 TP monitor interface operations. |
Action |
No action is required. |
ADAK040 | Enabling Adabas task related user exit |
Explanation |
During CICS PLTPI processing, the Adabas task-related user exit has been enabled. |
ADAK041 | Extractxing global work area (GWA) |
Explanation |
During CICS PLTPI processing, CICS is determining the location of the global work area (GWA) for the command-level link components. |
ADAK042 | Initializing Adabas link routine |
Explanation |
During CICS PLTPI processing, an initialization call is being made to the command-level link routine. |
ADAK043 | Initializing Adabas SVC communication |
Explanation |
During CICS PLTPI processing, the Adabas SVC environment is being established. |
ADAK044 | Adabas vvrs CICS environment established |
Explanation |
During CICS PLTPI processing, the CICS environment needed for the command-level link components has been built. |
ADAK045 | T.R.U.E. true-name is in use by Adabas link routine link-name |
Explanation |
This message occurs during CICS PLTPI processing and displays the task-related user exit name and the Adabas link routine with which it is associated. |
ADAK046 | SVC number: svc default DBID: dbid |
Explanation |
This message occurs during CICS PLTPI processing and displays the default SVC number and DBID. |
ADAK047 | UB pool address: aaaaaaaa NUBS: nnnnn |
Explanation |
This message occurs during CICS PLTPI processing and displays the UB pool address and NUBS value. |
ADAK048 | User exit after (A) address: { aaaaaaaa | NOT IN USE } |
Explanation |
This message occurs during CICS PLTPI processing and displays the address of the Adabas user exit 1 (user exit A in Adabas 7) or "not in use" if the user exit is not in use. |
ADAK049 | User exit before (B) address: { aaaaaaaa | NOT IN USE } |
Explanation |
This message occurs during CICS PLTPI processing and displays the address of the Adabas user exit B or "not in use" if user exit B is not in use. |
ADAK05 | DDLNKPAR open error: ret-code |
Explanation |
During BS2000 TP monitor interface operations, Adalink failed to open the parameter file. The value ret-code given in the message is the DMS return code. |
Action |
Use a SAM/V format for this file. |
ADAK050 | Review exit address: { aaaaaaaa | NOT IN USE } |
Explanation |
This message occurs during CICS PLTPI processing and displays the address of the Adabas Review exit, or "not in use" if the Adabas Review exit is not in use. |
ADAK051 | Adabas SAF Security (ADASAF) in use |
Explanation |
During CICS PLTPI processing, the Adabas external security interface (ADASAF) is in use. This message is not displayed if ADASAF is not in use. |
ADAK052 | Adabas Transaction Manager (ATM) in use |
Explanation |
During CICS PLTPI processing, Adabas transactions are being coordinated through the CICS Resource Manager Interface (RMI) using the Adabas Transaction Manager (ATM). This message is not displayed if the RMI is not in use. |
ADAK053 | Adabas Bridge for VSAM (AVB) in use |
Explanation |
During CICS PLTPI processing, the Adabas Bridge for VSAM (AVB) is in use. This message is not displayed if AVB is not in use. |
ADAK054 | T.R.U.E. global work area (GWA) address: aaaaaaaa |
Explanation |
This message occurs during CICS PLTPI processing and displays the address allocated to the global work area. |
ADAK055 | Adabas link routine EPA: aaaaaaaa |
Explanation |
This message occurs during CICS PLTPI processing and displays the entry point address (EPA) of the Adabas link routine. |
ADAK056 | Adabas link routine D.C.I. EPA: aaaaaaaa |
Explanation |
This message occurs during CICS PLTPI processing and displays the entry point address (EPA) of the Adabas link routine direct call interface (DCI). |
ADAK057 | Adabas SVC IDTH address: aaaaaaaa |
Explanation |
This message occurs during CICS PLTPI processing and displays the address of the Adabas SVC IDT header. |
ADAK058 | RESYNC command issued |
Explanation |
During CICS PLTPI processing, the CICS RMI for Adabas is in use and resynchronization will now take place for any incomplete transactions involving Adabas databases. |
ADAK059 | ATM inactive; RESYNC deferred |
Explanation |
During CICS PLTPI processing, the CICS RMI for Adabas is in use and resynchronization may be required for incomplete transactions involving Adabas databases. However, the Adabas Transaction Manager (ATM) is not currently active. Resynchronization will occur when ATM is restarted. |
ADAK06 | ADALINK statements ignored, because ADARUN statements present |
Explanation |
During BS2000 TP monitor interface operations, Adalink is running in a nucleus or utility context, or in a user context together with ADARUN. When either is the case, the Adalink statements are ignored. Processing continues. |
Action |
For the Adalink statements to be effective, specify them in a non-nucleus or non-utility context, and without ADARUN statements. |
ADAK061 | ADATRUE - Enable stage failed EIBRESP: xxxxxxxx1 EIBRESP2: xxxxxxxx2 |
Explanation |
The task related user exit could not be enabled due to the EIB response code xxxxxxxx1 and EIB response code 2 xxxxxxxx2. |
Action |
Consult the appropriate CICS documentation to determine the cause of the error in the exec interface block (EIB). |
ADAK062 | ADATRUE extract GWA failed EIBRESP: xxxxxxxx1 EIBRESP2: xxxxxxxx2 |
Explanation |
The requested task-related user exit global storage could not be EXTRACTed due to the EIB response and response 2 codes given as xxxxxxxx1 and xxxxxxxx2. |
Action |
Consult the appropriate CICS documentation to determine the cause of the error in extracting the global work area. |
ADAK063 | Initialization call to link routine failed EIBRCODE: xxxxxxxx ADARSP: nnnn |
Explanation |
The Initialize Link command (IL) could not be executed because of EIB response code xxxxxxxx, or Adabas response code nnnn. |
Action |
If the EIBRCODE field returns a non-zero value, consult the appropriate CICS documentation to determine the cause of the error. If the ADARSP returns a non-zero value, consult the response codes in chapter 2. |
ADAK064 | Adabas call to establish IDTH failed |
Explanation |
The close command (CL) to Adabas failed due a response code other than response 148. |
Action |
Most often, this is caused by an incorrect Adabas SVC number in the ADAGSET macro; otherwise, check to see that the Adabas SVC is installed, and at the correct version. |
ADAK065 | Invalid D.C.I addrss - cannot continue |
Explanation |
The IDTH address was not set by the command-level link routine during the CL command. |
Action |
Verify that the correct version of the Adabas command-level link routine is installed, and that the entry point name "ENTPT=" in ADAGSET is correct. |
ADAK066 | ADACIC0 version: version does not match Adabas link |
Explanation |
The ADACIC0 version does not match the version of the ADATRUE or Adabas link routine being installed. All three modules must be at the same version for the install to succeed. |
Action |
Verify that the correct version of all three modules is installed. |
ADAK067 | Link to ADACIRQ failed EIBRESP: rc |
Explanation |
This error occurs when the ADACIRQ program (which is used to read the DDLINK card containing the globals table name under CICS) cannot be located. This error may occur in one of the following instances:
|
Action |
Verify that the ADACIRQ load module or phase is available to the running CICS and that it is properly defined to CICS and the definition is installed. If the error persists, contact your Software AG technical support representative for assistance. |
ADAK068 | RMI initialization error: CMD: cmd RESP: resp RC: rc |
Explanation |
The RMI initialization routine could not complete its processing due to the indicated error. The message may provide a failing CICS command (cmd) and response code (resp), or an ATM error code (rc) and, if relevant, Adabas response code (resp). |
Action |
Investigate the meaning of the displayed response code and/or error code. If possible, correct the error; otherwise, report the details to your Software AG technical support representative. |
ADAK069 | message-text | |||||||||
Explanation |
Various message texts may be provided using this message number. Review the table below to determine the cause of the error and the course of action to take.
|
|||||||||
Action |
The action that should be taken depends on the message text issued with this message number. Review the table above for the appropriate action. |
ADAK07 | LRVINFO>0 and module REVEXITB not found, processing continues |
Explanation |
During BS2000 TP monitor interface operations, a nonzero LRVINFO parameter value was specified in the Adalink parameter, but the Adabas Review user exit B (REVEXITB) module could not be found. Program processing continues without REVEXITB. |
Action |
Either specify LRVINFO=0, remove the LRVINFO parameter statement, or include the REVEXITB module in the program. |
ADAK070 | Adabas T.R.U.E. disabled module-name |
Explanation |
A failure occurred during the execution of the enhanced installation program. The Adabas TRUE (Task Related User Exit) is disabled. The name of the Adabas TRUE module being installed is given in the message (module-name). |
Action |
Determine the cause of the failure. The reason for the failure may be determined by examining previous messages produced by the ADACIC0 installation program. These messages are written to the JES joblog for z/OS and to SYSLOG for VSE. For more information please consult your Adabas installation documentation. |
ADAK071 | Adabas link routine released module-name |
Explanation |
A failure occurred during the execution of the enhanced installation program. The CICS command-level link routine has been released. The name of the Adabas CICS command-level link routine being installed is given in the message (module-name). |
Action |
Determine the cause of the failure. The reason for the failure may be determined by examining previous messages produced by the ADACIC0 installation program. These messages are written to the JES joblog for z/OS and to SYSLOG for VSE. For more information please consult your Adabas installation documentation. |
ADAK072 | GETMAIN for UB-POOL failed EIBRESP: 0000nnnn |
Explanation |
The CICS GETMAIN for shared storage for the Adabas user buffer pool failed. The returned value of EIBRESP from the CICS request is printed in hexadecimal at the end of the message. |
Action |
Consult the appropriate IBM CICS documentation for the meaning of the returned EIBRESP value. |
ADAK073 | Freemain for UB-POOL failed EIBRESP: 0000nnnn |
Explanation |
The storage for the Adabas user buffer pool was not released. The returned value of EIBRESP from the CICS FREEMAIN request is returned at the end of the message. |
Action |
Consult the appropriate IBM CICS documentation for the meaning of the returned EIBRESP value. |
ADAK074 | Adabas DBID/SVC table in use is: table-name |
Explanation |
The LGBLSET parameters DYNDBSVC=YES and DBSVCTN=dbid-svc-tbl-name parameters are coded in the CICS link globals table and the named DBID/SVC routing table is found and loaded. The name of the DBID/SVC routing table is given in the message (table-name). |
Action |
No action is required for this informational message. |
ADAK08 | Review exit B deactivated. processing continues |
Explanation |
During BS2000 TP monitor interface operations, LRVINFO=0 was either specified or omitted in the Adalink parameter or the entire Adalink parameter service is inactive, and the Adabas Review user exit B (REVEXITB) is present in the user program. |
Action |
To activate REVEXITB, specify LRVINFO=256; otherwise, no change is necessary. |
ADAK09 | Incompatible versions of ADALNK and ADAL2P, processing aborted |
Explanation |
During BS2000 TP monitor interface operations, it was determined that the versions of ADALNK and ADAL2P do not match. |
Action |
Check library assignments; check TSOSLNK/BINDER protocols. |
ADAK10 | ADAUSER type for entry module RC rc |
Explanation |
During BS2000 TP monitor interface operations, an error occurred while attempting to access the Adabas link module where type is either REQM for requesting memory or BIND for attempting to load; module is the name of the module to be accessed; and rc is the Fujitsu Technology Solutions macro return code. |
Action |
If the type is
|
ADAK73 | syntax-error-message-text | |||||||||||||||||||||
Explanation |
An error occurred when the ADACIRQ program encountered syntax errors while processing DDLINK input data read from the Adabas CICS transient data queue during initialization and startup of the Adabas 8 CICS link routine and task-related user exit (TRUE). The format and proper keyword values are discussed in Preparing DDLINK Input for CICS . Possible error message texts that might appear with this message number and the appropriate action that should be taken to correct each problem are given in the table below.
|
|||||||||||||||||||||
Action |
Refer to the table above for appropriate actions. |