The persistent store is used for storing unit-of-work messages and publish-and-subscribe data to disk. This means message and status information can be recovered after a hardware or software failure to the previous commit point issued by each application component. Under z/VSE, the broker persistent store can be implemented with the Adabas database of Software AG. This document covers the following topics:
See also Concepts of Persistent Messaging.
EntireX provides an Adabas persistent driver. This enables Broker unit of work (UOW) messages and their status to be stored in an Adabas file. It is designed to work with Adabas databases under z/OS, UNIX, Windows, BS2000/OSD and z/VSE, and can be used where the database resides on a different machine to Broker kernel. For performance reasons, we recommend using EntireX Broker on the same machine as the Adabas database.
To create an Adabas Persistent Store, adapt and run job PSFADA.J
in sublibrary EXX960
.
Running this job will load an empty Adabas persistent store file into your
Adabas database. To activate the Adabas persistent store, set up at least
following parameters in the broker attribute file. See Broker Attributes.
DEFAULTS=BROKER STORE = BROKER PSTORE = HOT/COLD PSTORE-TYPE = ADABAS DEFAULTS=ADABAS DBID =dbid
FNR =pstore_file_number
DEFAULTS=NET ADASVC =svc_number
See Managing the Broker Persistent Store for more information.
If a HOT start is performed, the Broker kernel must be executed on the same platform on which also the previous Broker executed. This is because some portions of the persistent data are stored in the native character set and format of the Broker kernel. It is also necessary to start Broker with the same Broker ID as the previous Broker executed.
If a COLD start is executed, a check is made to ensure the Broker ID and
platform information found in the persistent store file is consistent with the
Broker being started (provided the persistent store file is not empty). This is
done to prevent accidental deletion of data in the persistent store by a
different Broker ID. If you intend to COLD start Broker and to utilize a
persistent store file which has been used previously by a different Broker ID,
you must supply the additional PSTORE-TYPE
parameter FORCE-COLD=Y
.
Perform regular backup operations on your Adabas database. The persistent store driver writes C1 checkpoint records at each start up and shut down of Broker.
For performance reasons, execute Broker on the same machine as Adabas.
During startup, Broker writes the following C1 checkpoint records to
the Adabas database. The time, date and job name are recorded in the Adabas
checkpoint log. This enables Adabas protection logs to be coordinated with
Broker executions. This information can be read from Adabas, using the
ADAREP
utility with option
CPLIST
:
Broker Execution Name | Broker Execution Type | Adabas |
---|---|---|
ETBC | Broker Cold Start | Normal Cold Start |
ETBH | Broker Hot Start | Normal Hot Start |
ETBT | Broker Termination | Normal Termination |
Caution should be exercised when defining the block size
(BLKSIZE
) parameter for the Adabas persistent store.
This determines how much UOW message data can be stored within a single Adabas
record. Therefore, do not define a much larger block size than the size of the
maximum unit of work being processed by Broker. (Remember to add 41 bytes for
each message in the unit of work.) The advantage of having a good fit between
the unit of work and the block size is that fewer records are required for each
I/O operation.
It is necessary to consider the following Adabas parameters and settings when using Adabas for the persistent store file:
Topic | Description | ||||||||
---|---|---|---|---|---|---|---|---|---|
Allowing Sufficient Adabas UQ Elements | Allow sufficient Adabas user queue (UQ) elements each time you
start Broker. The Broker utilizes a number of user queue elements equal to the
number of worker tasks (NUM-WORKER ), plus two.
Adabas timeout parameter (TNAE ) determines how long the
user queue elements will remain. This can be important if Broker is restarted
after an abnormal termination, and provision must be made for sufficient user
queue elements in the event of restarting Broker.
|
||||||||
Setting Size of Hold Queue Parameters | Consideration must be given to the Adabas hold queue parameters
NISNHQ and NH . These must be
sufficiently large to allow Adabas to add/update/delete the actual number of
records within a single unit of work.
Example: where there are 100 message within a unit of work and the
average message size is 10,000 bytes, the total unit of work size is 1 MB. If,
for example, a 2 KB block size (default |
||||||||
Setting Adabas TT Parameter | Consideration must be given to the Adabas transaction time
(TT ) parameter for cases where a large number of records
is being updated within a single unit of work.
|
||||||||
Defining LWP Size | Sufficient logical work pool (LWP ) size
must be defined so that the Adabas persistent store can update and commit the
units of work. Adabas must be able to accommodate this in addition to any other
processing for which it is used.
|
||||||||
Executing Broker Kernel and Adabas Nucleus on Separate Machines | If Broker kernel is executed on a separate machine to the
Adabas nucleus, with a different architecture and codepage, then we recommend
running the Adabas nucleus with the UEC (universal
conversion) option in order to ensure that Adabas C1 checkpoints are legible
within the Adabas checkpoint log.
|
||||||||
Setting INDEXCOMPRESSION=YES |
This Adabas option can be applied to the Adabas file to reduce by approximately 50% the amount of space consumed in the indexes. | ||||||||
4-byte ISNs | If you anticipate having more than 16 million records within the persistent store file, you must use 4-byte ISNs when defining the Adabas file for EntireX. | ||||||||
Specification of Adabas LP Parameter |
|
To calculate the Adabas file size it is necessary to estimate the number of records being stored. As an approximate guide, there will be one Adabas record (500 bytes) for each unprocessed unit of work, plus also n records containing the actual message data, which depends on the logical block size and the size of the unit of work. In addition, there will be one single record (500 bytes) for each unit of work having a persisted status.
Always allow ample space for the Adabas persistent store file since the continuous operation of Broker relies of the availability of this file to store and retrieve information.
In this example there are 100,000 Active UOW records at any one time. Each of these is associated with two message records containing the message data. UOW records are 500 bytes in length. Each message record contains 2,000 bytes. In addition, there are 500,000 UOW status records residing in the persistent store, for which the UOW has already been completely processed. These are 500 bytes long.
Note:
The actual size of the data stored within the UOW message records is
the sum of all the messages within the UOW, plus a 41-byte header for each
message. Therefore, if the average message length is 59 bytes, the two 2,000
bytes, messages records, could contain n = 4,000 / (59+41), or 40 messages.
Adabas is assumed to compress the message data by 50% in the example (this can
vary according to the nature of the message data).
3-byte ISNs and RABNs are assumed in this example. A device type of 8393 is used; therefore, the ASSO block size is 4,096, and DATA block size is 27,644. Padding factor of 10% is specified.
The following example calculates the space needed for Normal Index (NI), Upper Index (UI), Address Converter (AC) and Data Storage (DS).
Calculation Factors | Required Space |
---|---|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Entity Requiring Space | Total Required Space |
Normal Index (NI) | = 23,868 blocks |
Upper Index (UI) | = 512 blocks |
Data Storage (DS) | = 14,068 blocks |
Address Converter (AC) | = 587 blocks |
Entire Net-Work
If you intend to use Adabas persistent store through Entire
Net-Work, see the Entire Net-Work documentation for installation and
configuration details.
Adabas Versions
Adabas persistent store can be used on all Adabas versions currently
released and supported by Software AG.
Prerequisite Versions of Entire Net-Work with Adabas
See the Adabas and Entire Net-Work documentation to determine
prerequisite versions of Entire Net-Work to use with Adabas at your site.
The contents of EntireX Broker's persistent store can be migrated to a new persistent store in order to change the PSTORE type or to use the same type of PSTORE with increased capacity.
The migration procedure outlined here requires two Broker instances
started with a special RUN-MODE
parameter. One
Broker unloads the contents of the persistent store and transmits the data to
the other Broker, which loads data into the new PSTORE. Therefore, for the
purposes of this discussion, we will refer to an unload Broker and a
load Broker.
This procedure is based on Broker-to-Broker communication to establish a communication link between two Broker instances. It does not use any conversion facilities, since the migration procedure is supported for homogeneous platforms only.
The migration procedure requires two Broker instances started with the
RUN-MODE
parameter. The unload Broker should be started with the following
attribute:
RUN-MODE=PSTORE-UNLOAD
The load Broker should be started with the following attribute:
RUN-MODE=PSTORE-LOAD
These commands instruct the Broker instances to perform the PSTORE migration.
Note:
The attribute PARTNER-CLUSTER-ADDRESS
must be defined in both Broker instances to specify the transport address of
the load Broker. The unload Broker must know the address of the load broker,
and the load Broker must in turn know the address of the unload Broker.
Broker ETB001 performs the unload on host HOST1, and Broker ETB002 performs the load on host HOST2. The transmission is based on TCP/IP. Therefore, Broker ETB001 starts the TCP/IP communicator to establish port 1971, and Broker ETB002 starts the TCP/IP communicator to establish port 1972.
For ETB001, attribute PARTNER-CLUSTER-ADDRESS=HOST2:1972:TCP
is set, and for ETB002, attribute
PARTNER-CLUSTER-ADDRESS=HOST1:1971:TCP
is set
to establish the Broker-to-Broker communication between the two Broker
instances.
In addition to attributes RUN-MODE
and
PARTNER-CLUSTER-ADDRESS
, a fully functioning
Broker configuration is required when starting the two Broker instances. To
access an existing PSTORE on the unloader side, you must set the attribute
PSTORE=HOT
. To load the data into the new
PSTORE on the loader side, you must set the attribute PSTORE=COLD
. The load process requires an empty PSTORE at the
beginning of the load process.
Note:
Use caution not to assign PSTORE=COLD
to your unload Broker instance, as this startup process
will erase all data currently in the PSTORE.
For the migration process, the unload Broker and the load Broker must be assigned different persistent stores.
A report can be generated to detail all of the contents of the existing
persistent store. At the end of the migration process, a second report can be
run on the resulting new persistent store. These two reports can be compared to
ensure that all contents were migrated properly. To run these reports, set the
attribute PSTORE-REPORT=YES
. See PSTORE
for detailed description, especially for the file
assignment.
The migration procedure is made up of three steps.
The unload Broker and the load Broker instances can be started independently of each other. Each instance will wait for the other to become available before starting the unload/load procedure.
The unload Broker instance sends a handshake request to the load Broker instance in order to perform an initial compatibility check. This validation is performed by Broker according to platform architecture type and Broker version number. The handshake ensures a correctly configured partner cluster address and ensures that the user did not assign the same PSTORE to both Broker instances. If a problem is detected, an error message will be issued and both Broker instances will stop.
The unload Broker instance reads all PSTORE data in a special
non-destructive raw mode and transmits the data to the load Broker instance.
The load Broker instance writes the unchanged raw data to the new PSTORE. A
report is created if PSTORE-REPORT=YES
is
specified, and a valid output file for the report is specified.
The unload Broker instance requests a summary report from the load Broker instance to compare the amount of migrated data. The result of this check is reported by the unload Broker instance and the load Broker instance before they shut down.
When a Broker instances is started in RUN-MODE=PSTORE-LOAD
or RUN-MODE=PSTORE-UNLOAD
, the Broker instances only allow Administration
requests. All other user requests are prohibited.
Notes:
PSTORE=HOT
. Do not start your broker
with the new persistence store using PSTORE=COLD
; this startup process will erase all of the data in your
persistent store.