If check box Turn on Autostart for default EntireX Broker is checked during installation, the default broker ETB001 is started.
To start the default broker
From the Windows start menu, choose
.To stop the default broker
From the Windows start menu, choose
.Before starting the Broker, it must be configured to correctly use SSL or TLS as a transport mechanism:
Append "-SSL"
to the TRANSPORT
attribute. For example:
DEFAULTS = BROKER TRANSPORT = TCP-SSL
See also TRANSPORT
.
Set the SSL or TLS attributes, for example:
DEFAULTS = SSL KEY-STORE = "C:\SoftwareAG\EntireX\etc\ExxAppCert.pem" KEY-PASSWD-ENCRYPTED = MyAppKey KEY-FILE = "C:\SoftwareAG\EntireX\etc\ExxAppKey.pem" VERIFY-CLIENT = N PORT=1958
where 1958 is the default but can be changed to any port number.
See also SSL-specific Attributes under Broker Attributes and SSL or TLS and Certificates with EntireX.
To guarantee that a broker ID is unique on one machine, a named semaphore is created at
initialization. If this semaphore already exists for this broker ID,
initialization is terminated with message ETBE0168, "This instance of
broker already running". If as a result of an abnormal broker
termination this semaphore cannot be deleted completely, you can force a
restart of the Broker with Broker attribute FORCE=YES
.
This section covers the following topics:
The Broker TRACE-LEVEL
attribute determines the level of
tracing to be performed while Broker is running. The Broker has a master
TRACE-LEVEL
specified in the Broker section of
the attribute file as well as several individual
TRACE-LEVEL
settings that are specified in the
following sections of the attribute file. You can also modify the different
TRACE-LEVEL
values while Broker is running,
without having to restart the Broker kernel for the change to take effect.
For temporary changes to
TRACE-LEVEL
without restarting the Broker, use
the System Management Hub.
Individual Settings | Specified in Attribute File Section |
---|---|
Master trace level | DEFAULTS=BROKER |
Persistent store trace level | DEFAULTS=ADABAS | CTREE | DIV
(currently not available for DIV)
|
Conversion trace level | Trace option of the CONVERSION
parameter that can be defined in DEFAULTS=SERVICE |
TOPIC
|
Security trace level | DEFAULTS=SECURITY |
These individual TRACE-LEVEL
values
determine the level of tracing within each subcomponent. If not specified, the
master TRACE-LEVEL
is used.
Trace Level | Description |
---|---|
0 | No tracing. Default value. |
1 | Traces incoming requests, outgoing replies, and resource usage. |
2 | All of Trace Level 1, plus all main routines executed. |
3 | All of Trace Level 2, plus all routines executed. |
4 | All of Trace Level 3, plus Broker ACI control block displays. |
8 | All of Trace Level 4, plus Adabas Persistent Store Adabas control blocks. |
Note:
Trace levels 2 and above should be used only when requested by
Software AG support.
It is not always convenient to run with
TRACE-LEVEL
defined, especially when higher
trace levels are involved. Deferred tracing is triggered when a specific
condition occurs, such as an ACI response code or a broker subtask abend. Such
conditions cause the contents of the trace buffer to be written, showing trace
information leading up the specified event. If the specified event does not
occur, the Broker trace will contain only startup and shutdown information
(equivalent to TRACE-LEVEL=0
). Operating the
trace in this mode requires the following additional attributes in the broker
section of the attribute file. Values for
TRBUFNUM
and
TRAP-ERROR
are only examples.
Attribute | Value | Description |
---|---|---|
TRBUFNUM |
3 | Specifies the deferred trace buffer size = 3 * 64 K. |
TRMODE |
WRAP | Indicates trace is not written until an event occurs. |
TRAP-ERROR |
322 | Assigns the event ACI response code 00780322 "PSI: UPDATE failed". |
An optional feature of EntireX Broker is available to protect a broker
running with SECURITY=YES
against
denial-of-service attacks. An application that is running with invalid user
credentials will get a security response code. However, if the process is doing
this in a processing loop, the whole system could be affected. If
PARTICIPANT-BLACKLIST
is set to YES
, EntireX Broker maintains a
blacklist to handle such "attacks". If an application causes ten
consecutive security class error codes within 30 seconds, the blacklist handler
puts the participant on the blacklist. All subsequent requests from this
participant are blocked until the
BLACKLIST-PENALTY-TIME
has elapsed.
Here is a scenario illustrating another use of this feature that is not security-related.
An RPC server is to be shut down immediately, using Broker Command and Information
Services (CIS), and has no active request in the broker. The shutdown results
in the LOGOFF
of the server. The next request that
the server receives will probably result in message 00020002 "User
does not exist", which will cause the server to reinitialize
itself. It was not possible to inform the server that shutdown was meant to be
performed.
With the blacklist, this is now possible. As long as the blacklist is not switched off, when a server is shut down immediately using CIS and when there is no active request in the broker, a marker is set in the blacklist. When the next request is received, this marker results in message 00100050 "Shutdown IMMED required", which means that the server is always informed of the shutdown.