This message class is returned when EntireX Broker detects an error situation. The situation should be examined using the error number returned and after correction, the applications can be restarted. The messages have the format:
0078nnnn
where | 0078 | is the message class, and |
nnnn | is the message number in the range 0000 - 9999 |
00780008 | 00780055 | 00780058 | 00780093 | 00780198 | 00780221 | 00780224 | 00780232 | 00780238 | 00780239 | 00780241 | 00780244 | 00780245 | 00780254 | 00780258 | 00780259 | 00780260 | 00780261 | 00780262 | 00780265 | 00780266 | 00780277 | 00780299 | 00780304 | 00780305 | 00780306 | 00780307 | 00780308 | 00780309 | 00780310 | 00780319 | 00780320 | 00780321 | 00780322 | 00780323 | 00780326 | 00780328 | 00780337 | 00780338 | 00780350 | 00780351 | 00780352 | 00780356 | 00780357 | 00780358 | 00780375 | 00780386 | 00780388 | 00780389 | 00780405 | 00780406 | 00780407 | 00780409 | 00780410 | 00780575 | 00780615 | 00780617 | 00780623 | 00780624 | 00780626 | 00780655 | 00780777 | 00780778 | 00780779 | 00780798 | 00780844 | 00780848 | 00780852 | 00370853 | 00780854 | 00780855 | 00780857 | 00780858 | 00780955
00780008 | No Related Text For Error Number |
Explanation |
EntireX Broker has tried to return an error number that it cannot find in the table of known messages. |
Action |
Contact Software AG Support. |
00780055 | TRE Entry Not Active |
Explanation |
The translation routine cannot be loaded (in |
Action |
Contact Software AG Support. |
00780058 | Failed to get memory from OS |
Explanation |
Broker could not get enough memory during initialization. |
Action |
Reduce the resource requirements in the attribute file OR increase the memory available to your broker job, if possible. |
00780093 | MQ Store Pointer Is Null |
Explanation |
EntireX Broker detected an error during release of storage. |
Action |
Contact Software AG Support. |
00780198 | No Related SCBEXT Entry For PCB |
Explanation |
A server issued a |
Action |
Contact Software AG Support. |
00780221 | SPFX Translation Code Error |
Explanation |
This is a problem with the Broker stub used by the application. The stub did not send the EntireX Broker call in the correct internal format. |
Action |
Ensure that the correct version of the EntireX Broker stub is being used. Check the log data set for an image of the internal format. Examine this string for the user issuing the call. |
00780224 | POST/WAIT error occurred |
Explanation |
The internal communication of Broker failed due to an operating system error. |
Action |
Contact Software AG Support. |
00780232 | PSI: Query release failed |
Explanation |
Resources obtained for a Command and Infor Services query cannot be released. |
Action |
Contact Software AG Support. |
00780238 | PSTORE is currently disconnected |
Explanation |
Currently, PSTORE is disconnected. Any active operation involving PSTORE
is currently prohibited. This situation can occur when the Broker administrator
has issued the CIS command |
Action |
It may take some time before PSTORE is connected again. Be careful
not to have a loop programmed in this situation. Retry the call to EntireX
Broker after the Broker administrator has issued the command
|
00780239 | Invalid length in format string |
Explanation |
EntireX Broker has detected an internal inconsistency during info or command processing. The internal field length description is corrupted. |
Action |
Contact Software AG Support. |
00780241 | No free service extension entry |
Explanation |
EntireX Broker has detected an error while searching for a free SCB extension entry. There is no SCB extension entry available. |
Action |
This error should not occur with With You may retrieve the allocated number of service extensions by using the program |
00780244 | No free translation entry |
Explanation |
The Broker has detected an error while searching for a free TRE entry. There is no TRE entry available. |
Action |
Contact Software AG Support. |
00780245 | No related service entry for client |
Explanation |
The Broker has detected an error while searching for the client SCB entry. There is no SCB entry for the client. |
Action |
Contact Software AG Support. |
00780254 | Invalid type in format string |
Explanation |
The Broker has detected an internal inconsistency during info or command processing. The internal description of the field type is corrupted. |
Action |
Contact Software AG Support. |
00780258 | Pointer to next segment is null |
Explanation |
Internal error during assembly of the Info return buffer. |
Action |
Contact Software AG Support. |
00780259 | No related timeout queue entry |
Explanation |
EntireX Broker has detected an error in TOQ structures. |
Action |
Contact Software AG Support. |
00780260 | Pointer to Info structure is null |
Explanation |
Internal error during inquiry of Info services. |
Action |
Contact Software AG Support. |
00780261 | No free participant entry |
Explanation |
The Broker has detected an error while searching for a free PCB entry. There is no PCB entry available. |
Action |
Increase |
00780262 | No free participant extension entry |
Explanation |
The Broker has detected an error while searching for a free PCB extension entry. There is no PCB extension entry available. |
Action |
If you are not using dynamic memory management (Broker attribute |
00780265 | No free service entry |
Explanation |
The Broker has detected an error while searching for a free SCB (Service Control Block) entry.
There is no SCB entry available. The number of SCBs is set based upon the
number of clients, servers, and services. When this error is returned, it means that all of the SCBs are
in use. The current formula for the number of SCBs is: |
Action |
Recommendations:
Increasing the values will increase the total number of SCBs. To free up the idle SCBs sooner:
Decreasing the non-activity timers will cause the inactive resources to be made available to other users. If |
00780266 | Inconsistency at start Info/Cmd-Service |
Explanation |
An inconsistency occurred during the start of internal Info or Command Services. |
Action |
Contact Software AG Support. |
00780277 | PSI: Replace operation failed |
Explanation |
The PSTORE operation to replace the contents of a unit of work failed. |
Action |
Examine the Broker log file for more information and contact Software AG Support if necessary. |
00780299 | Only supported for messages (no UOWs) |
Explanation |
An EntireX Broker function for a conversation with no units of work is requested, but the specified conversation contains units of work. The function is rejected. |
Action |
Check the supplied conversation ID. |
00780304 | No free UOW control block |
Explanation |
The Broker detected an error while searching for a free UWCB entry. No UWCB entry is available. |
Action |
Contact Software AG Support. |
00780305 | No matching UOW found |
Explanation |
A client issued a |
Action |
This is a user error. Clients must ensure that the UOWs exist before any request is made. |
00780306 | UOWs not found for UOWID=BOTH |
Explanation |
A client issued a |
Action |
This is a user error. Clients must ensure that the UOWs to be operated on exist and are in the correct status. |
00780307 | UOW is not in correct status |
Explanation |
A client issued a |
Action |
This is a user error. Clients must ensure that the UOWs are in the correct status. |
00780308 | UOW was not created by caller |
Explanation |
A client issued a |
Action |
This is a user error. Only the creator of a UOW can |
00780309 | Error updating UOW status |
Explanation |
An error occurred while updating the persistent status of a UOW. The error is in the persistent store facility. |
Action |
Examine the Broker log file to determine the type of error encountered. Contact Software AG Support if necessary. |
00780310 | Mismatched UOWs Store Type |
Explanation |
The store type specified with a |
Action |
Do not change the store type after the first |
00780319 | PSI: WRITE failed |
Explanation |
An attempt to write data to the persistent store has failed. |
Action |
Examine the Broker log file for more information and contact Software AG Support if necessary. |
00780320 | PSI: READ control data failed |
Explanation |
An attempt to read control data from the persistent store has failed. |
Action |
Examine the Broker log file for more information and contact Software AG Support if necessary. |
00780321 | PSI: READ message data failed |
Explanation |
An attempt to read message data from the persistent store has failed. |
Action |
Examine the Broker log file for more information and contact Software AG Support if necessary. |
00780322 | PSI: UPDATE failed |
Explanation |
An attempt to update the persistent store has failed. |
Action |
Examine the Broker log file for more information and contact Software AG Support if necessary. |
00780323 | PSI: WRITE both failed |
Explanation |
An attempt to write two data items to the persistent store has failed. |
Action |
Examine the Broker log file for more information and contact Software AG Support if necessary. |
00780326 | PSI: PURGE failed |
Explanation |
An attempt to delete data from the persistent store has failed. |
Action |
Examine the Broker log file for more |
00780328 | PSI: Scan operation failed |
Explanation |
An attempt to scan for selected data on the persistent store has failed. |
Action |
Examine the Broker log file for more information and contact Software AG Support if necessary. |
00780337 | Duplicate UOWID found |
Explanation |
Two UOWs with the same ID, on the same conversation, were encountered during restart. The Broker will not initialize. |
Action |
It will be necessary to delete one or both of the UOWs before restarting. Contact Software AG Support if necessary. |
00780338 | Exit attempted to change message size |
Explanation |
An encryption or decryption security exit attempted to change the size of a message. |
Action |
Correct the user exit so that message sizes are not changed. Note: |
00780350 | UOW operations not allowed |
Explanation |
A request has specified a unit of work (UOW) operation. But because the
broker-specific attribute |
Action |
Ensure that the request is directed to the correct Broker and that the Broker supports UOWs. |
00780351 | UOWID required for COMMIT/BACKOUT/CANCEL |
Explanation |
A |
Action |
Provide a |
00780352 | Invalid message length |
Explanation |
The message allocator is getting a request to obtain space for a message lower than or equal to zero. The request is rejected. |
Action |
Contact Software AG Support. |
00780356 | Error Updating Receiver Data |
Explanation |
An error occurred while updating the receiver data of a UOW in the persistent store. |
Action |
Examine the Broker log file to determine the type of error encountered. Contact Software AG Support if necessary. |
00780357 | Message Queue Inconsistent |
Explanation |
Broker keeps track of the sequence for sent and received non-persistent messages. The expected message number on receive does not match with the message number in the message queue control block. This indicates inconsistent data in the Broker memory pool. Broker will issue an error message and return this response code in the ACI. |
Action |
Contact Software AG Support. |
00780358 | PSI: Query operation failed |
Explanation |
The PSTORE operation to run a query is failed. |
Action |
Examine the Broker log file for more information and contact Software AG Support if necessary. |
00780375 | No storage for Translation Buffer |
Explanation |
The Broker could not allocate enough memory for a buffer into which the message to be character-converted should be copied. |
Action |
As a short-term measure try reducing the number of worker tasks
( |
00780386 | No free conversation accounting entry |
Explanation |
This message indicates a shortage of accounting control blocks. |
Action |
Increase |
00780388 | PSI: UOWs can NOT be persisted |
Explanation |
A request for a UOW to be persisted ( |
Action |
Review Broker attribute settings related to the persistent store. |
00780389 | PSI: UOW status can NOT be persisted |
Explanation |
A request for a UOW status to be persisted cannot be accomplished, since
at startup, the Broker attributes specify no persistent store ( |
Action |
Review Broker attribute settings related to the persistent store. |
00780405 | PSI: UOW Index initialization failed |
Explanation |
EntireX Broker tried to create an internal index for every unit of work. This operation failed. |
Action |
Examine the Broker log file for more information and contact Software AG Support if necessary. |
00780406 | PSI: Add entry to UOW Index failed |
Explanation |
EntireX Broker tried to add an entry to the internal index for units of work. This operation failed. |
Action |
Examine the Broker log file for more information and contact Software AG Support if necessary. |
00780407 | PSI: Logical read failed |
Explanation |
The logical read operation through the Adabas PSTORE returned an error. |
Action |
Examine the Broker log file for more information and contact Software AG Support if necessary. |
00780409 | PSI: Delete entry from UOW Index failed |
Explanation |
EntireX Broker tried to delete an entry from the internal index for units of work. This operation failed. |
Action |
Examine the Broker log file for more information and contact Software AG Support if necessary. |
00780410 | PSI: Close UOW Index failed |
Explanation |
EntireX Broker tried to close the internal index for units of work. This operation failed. |
Action |
Examine the Broker log file for more information and contact Software AG Support if necessary. |
00780575 | PSI: Set Trace Level failed |
Explanation |
Unable to set the persistent store-specific trace level. |
Action |
Contact Software AG Support. |
00780615 | No free filter entry |
Explanation |
An attempt to add a command log filter failed as there were no free command log filter entries. |
Action |
Delete an existing command log filter or specify an increased value for
the broker |
00780617 | Broker is waiting for operational PSTORE |
Explanation |
Broker was started with |
Action |
As soon as the persistent store is accessible, this temporary problem will no longer exist. Check that the assigned persistent store is in the process of starting. |
00780623 | No free TCP connection entry |
Explanation |
The maximum number of TCP/IP connections is derived from the number of available file descriptors. This maximum has been reached. |
Action |
Increase the number of file descriptors. |
00780624 | Broker not operational for user requests |
Explanation |
The Broker is not available for user requests. The |
Action |
Change the |
00780626 | No free node control block |
Explanation |
EntireX Broker has detected an error while searching for a free node control block. There is no node control block available. |
Action |
Contact Software AG Support. |
00780655 | Pool order failure |
Explanation |
The internal communication path between the task ordering a pool allocation and the task executing the order received an error. |
Action |
Broker log provides more detailed diagnostics about the reason not being able to perform post and wait between Broker threads. |
00780777 | Request has abended |
Explanation |
The current request caused an abnormal exception in the Broker. |
Action |
Contact your Administrator to send the diagnostic information of the Broker to Software AG Support. |
00780778 | Request not finished yet |
Explanation |
The Broker-to-Broker request has not finished yet. Broker is still waiting for the response of the partner Broker. |
Action |
None. |
00780779 | Request rejected |
Explanation |
User error loop was detected before and participant is currently not permitted to issue any Broker request. |
Action |
Wait until participant is unlocked. |
00780798 | Invalid data |
Explanation |
The Load Broker detected an inconsistency in the sent data. The expected end-of-data signature has not been sent. |
Action |
Contact Software AG Support. |
00780844 | PSTORE: Wrong master record |
Explanation |
UOW master record missing when reading UOW from Adabas PSTORE database. Indicates a corrupted or inconsistent Adabas PSTORE database. |
Action |
Running with |
00780848 | PSTORE: ADABAS error occurred |
Explanation |
A call to the Adabas database returned an error response. |
Action |
Check the Adabas response code for more details. |
00780852 | PSTORE: Invalid control data length |
Explanation |
The unit of work in the c-tree PSTORE contains incorrect data or an I/O error occurred. |
Action |
Check if a wrong |
00370853 | PSTORE: Persistent Store is full |
Explanation |
The space for the c-tree PSTORE is exhausted. |
Action |
Move the PSTORE files to a location with more disk space and adjust the c-tree-specific |
00780854 | PSTORE: Cannot set ADABAS USER-ID |
Explanation |
The request to set the Adabas user ID was not successful. |
Action |
Check the Adabas configuration. |
00780855 | PSTORE: Requested data out of range |
Explanation |
This error indicates a data inconsistency. |
Action |
Contact Software AG Support. |
00780857 | Unexpected API function triggered by RCB |
Explanation |
An internal error occurred in the processing of the receive function. |
Action |
Rerun Broker with |
00780858 | Cannot create RCB. malloc failed |
Explanation |
The runtime heap is too small. Broker was unable to allocate an RCB (Receive Control Block). |
Action |
Change the runtime settings to increase the size of the runtime heap. |
00780955 | No active authorization rules |
Explanation |
Broker was started with no section |
Action |
None. |