This document covers the following topics:
Related Statements: CLOSE WORK FILE
|
DEFINE WORK FILE
| WRITE WORK FILE
Belongs to Function Group: Control of Work Files / PC Files
The READ WORK FILE
statement is used to read data from a non-Adabas physical
sequential work file. The data is read sequentially from the work file. How it is read is
independent of how it was written to the work file.
READ WORK FILE
initiates and executes a processing loop for reading of all
records on the work file. Automatic break processing may be performed within a READ
WORK FILE
loop.
Notes:
READ WORK
FILE
statement, Natural automatically closes the work file.
READ WORK FILE
processing loop.
If an ASCII work file is read, it is possible that an empty record is returned as the last record after the last physical record. This is due to the fact that Natural does not read individual records, but reads larger blocks of the work file in order to optimize file-access performance.
READ
WORK [FILE ] work-file-number |
||||||||||||||||||||||
RECORD
operand1
|
||||||||||||||||||||||
[AND ]
[SELECT ]
|
operand2 | |||||||||||||||||||||
operand2 | operand4
[AND ] ADJUST [OCCURRENCES ]
|
|||||||||||||||||||||
[GIVING
LENGTH
operand3]
|
||||||||||||||||||||||
statement | ||||||||||||||||||||||
END-WORK
|
(structured mode only) | |||||||||||||||||||||
LOOP
|
(reporting mode only) |
For an explanation of the symbols used in the syntax diagram, see Syntax Symbols.
READ
WORK [FILE ] work-file-number
ONCE
|
||||||||||||||||||||||
RECORD
operand1
|
||||||||||||||||||||||
[AND ] [SELECT ]
|
operand2 | |||||||||||||||||||||
operand2 | operand4
[AND ] ADJUST [OCCURRENCES ]
|
|||||||||||||||||||||
[GIVING
LENGTH
operand3]
|
||||||||||||||||||||||
[AT [END ] [OF ] [FILE ]
statement
END-ENDFILE] (structured
mode only) |
||||||||||||||||||||||
AT [END ] [OF ] [FILE ]
|
(reporting mode only) |
For an explanation of the symbols used in the syntax diagrams, see Syntax Symbols.
Operand | Possible Structure | Possible Formats | Referencing Permitted | Dynamic Definition | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
operand1
|
S | A | G | A | U | N | P | I | F | B | D | T | L | C | yes | yes | ||||
operand2
|
S | A | G | A | U | N | P | I | F | B | D | T | L | C | yes | yes | ||||
operand3
|
S | I | yes | yes | ||||||||||||||||
operand4 |
A | A | U | N | P | I | F | B | D | T | L | C | no | no |
See also Field Lengths.
Syntax Element Description:
Syntax Element | Description |
---|---|
work-file-number
|
Work File Number: The work file number (as defined
to Natural) to be used.
The work file number is either
|
ONCE
|
ONCE Option:
If a |
RECORD
operand1
FILLER nX |
RECORD Option:
In reporting mode, an operand list
( In structured mode, or if the record to be used is defined using a No checking and no conversion is performed by Natural on the data contained in
the record. It is the user's responsibility to describe the record layout
correctly in order to avoid program abends caused by non-numeric data in numeric
fields. Because no checking is performed by Natural, this option is the fastest
way to process records from a sequential file. The record area defined by
See Overview of RECORD Option Usage below. |
SELECT |
|
operand4 AND ADJUST
OCCURRENCES |
ADJUST Clause:
Specify a one-dimensional X-array with complete range (*). The X-array is expanded or reduced to the number of occurrences needed to receive all data read. See Handling of X-Arrays below. Note: |
GIVING LENGTH
operand3
|
GIVING LENGTH Clause
This clause can be used to retrieve the actual length of the record being read.
The length (number of bytes) is returned in
If the work file is defined as If the |
AT END OF FILE
|
AT END OF FILE Clause
This clause can only be used in conjunction with the If the |
END-WORK
|
End of READ WORK FILE Statement:
In structured mode with processing loop, the Natural reserved word
|
LOOP |
End of READ WORK FILE Statement:
In reporting mode with processing loop, the Natural statement |
RECORD
Option
Usage
RECORD option is used with
|
rejected at compile time | rejected at runtime | RECORD option is ignored, processing switches
to SELECT mode
|
---|---|---|---|
work file type ENTIRECONNECTION |
x | ||
dynamic variables | x | ||
work file type CSV |
x | ||
work file type PORTABLE |
x | ||
work file types ASCII ,
ASCII-COMPRESSED , CSV , UNFORMATTED ,
code page is specified in Configuration Utility (conversion is necessary) or at least one
Unicode field is specified (operand of format U, conversion is necessary)
|
x |
The field lengths in the Operand Definition Table are determined as follows:
Format | Length |
---|---|
A, B, I, F | The number of bytes in the input record is the same as the internal length definition. |
N | The number of bytes in the input record is the sum of internal positions before and after the decimal point. The decimal point and sign do not occupy a byte position in the input record. |
P, D, T | The number of bytes in the input record is the sum of positions before and after the decimal point plus 1 for the sign, divided by 2 rounded upwards. |
L | 1 byte is used. For C format fields, 2 bytes are used. |
Field Definition | Input Record |
---|---|
#FIELD1 (A10) |
10 bytes |
#FIELD2 (B15) |
15 bytes |
#FIELD3 (N1.3) |
4 bytes |
#FIELD4 (N0.7) |
7 bytes |
#FIELD5 (P1.2) |
2 bytes |
#FIELD6 (P6.0) |
4 bytes |
See also Format and Length of User-Defined Variables in the Programming Guide.
When reading an array from a work file, you can specify a variable index range for the array. For example:
READ WORK FILE work-file-number #ARRAY (I:J)
Work File Type | Handling |
---|---|
The work file types Reading a dynamic variable from an |
|
|
The work file type |
The work file type The |
|
Large and dynamic variables can be written into work files or read from work
files using the two work file types Reading a dynamic variable from a |
|
The maximum field/record length is 32766 bytes for dynamic and large variables. Dynamic variables are supported. X-arrays are not allowed and will result in an error message. |
When the ADJUST
clause is not used, X-arrays are treated the same
as regular arrays; that is, their existing occurrences are filled.
When the ADJUST
clause is used, a one-dimensional X-array
specified with complete range (*) is processed as shown in the table:
Work File Type | Handling |
---|---|
|
A one-dimensional X-array specified with complete range (*) is expanded to receive all data from the rest of the record. |
A one-dimensional X-array specified with complete range (*) is expanded to receive all data from the rest of the file. | |
X-arrays are not supported. |
Example 3 - READ WORK FILE Unformatted with Dynamic Variable
Example 4 - READ WORK FILE ASCII with X-array and ADJUST its Occurrences
Example 5 - READ WORK FILE Unformatted with X-array and ADJUST its Occurrences
Example 6 - READ WORK FILE with Numeric CONST Variable as Work File Number
** Example 'RWFEX1': READ WORK FILE ************************************************************************ DEFINE DATA LOCAL 1 EMPLOY-VIEW VIEW OF EMPLOYEES 2 PERSONNEL-ID 2 NAME * 1 #RECORD 2 #PERS-ID (A8) 2 #NAME (A20) END-DEFINE * FIND EMPLOY-VIEW WITH CITY = 'STUTTGART' WRITE WORK FILE 1 PERSONNEL-ID NAME END-FIND * * ... * READ WORK FILE 1 RECORD #RECORD DISPLAY NOTITLE #PERS-ID #NAME END-WORK * END
#PERS-ID #NAME -------- -------------------- 11100328 BERGHAUS 11100329 BARTHEL 11300313 AECKERLE 11300316 KANTE 11500304 KLUGE 11500308 DIETRICH 11500318 GASSNER 11500343 ROEHM 11600303 BERGER 11600320 BLAETTEL 11500336 JASPER 11100330 BUSH 11500328 EGGERT
** Example 'RWFEX2': READ WORK FILE - ASCII with dynamic variable ******************************************************************** DEFINE DATA LOCAL 1 #DYNA (A) DYNAMIC END-DEFINE * DEFINE WORK FILE 1 TYPE 'ASCII' * WRITE WORK FILE 1 VARIABLE 'text1 text2 text3 ' WRITE WORK FILE 1 VARIABLE 'text4 text5' * READ WORK FILE 1 AND SELECT #DYNA DISPLAY *LENGTH(#DYNA) #DYNA (AL=40) /* /* Length: 18 Dyn.Var: 'text1 text2 text3' /* Length: 11 Dyn.Var: 'text4 text5' END-WORK * END
Page 1 11-07-15 09:21:09 LENGTH #DYNA ----------- ---------------------------------------- 18 text1 text2 text3 11 text4 text5
** Example 'RWFEX3': READ WORK FILE - Unformatted with dynamic variable ************************************************************************ DEFINE DATA LOCAL 1 #DYNA (A) DYNAMIC END-DEFINE * DEFINE WORK FILE 1 TYPE 'UNFORMATTED' * WRITE WORK FILE 1 VARIABLE 'text1 text2 text3 ' WRITE WORK FILE 1 VARIABLE 'text4 text5' * DEFINE WORK FILE 1 TYPE 'UNFORMATTED' * READ WORK FILE 1 AND SELECT #DYNA DISPLAY *LENGTH(#DYNA) #DYNA (AL=40) /* /* Length: 29 Dyn.Var: 'text1 text2 text3 text4 text5' END-WORK * END
Page 1 11-07-15 09:31:04 LENGTH #DYNA ----------- ---------------------------------------- 29 text1 text2 text3 text4 text5
** Example 'RWFEX4': READ WORK FILE - ASCII with X-array ** and ADJUST its occurrences ******************************************************************** DEFINE DATA LOCAL 1 #ARR (A6/1:*) 1 #OCC (I4) END-DEFINE * DEFINE WORK FILE 1 TYPE 'ASCII' * WRITE WORK FILE 1 VARIABLE 'text1 text2 text3 ' WRITE WORK FILE 1 VARIABLE 'text4 text5' * READ WORK FILE 1 AND SELECT #ARR(*) AND ADJUST OCCURRENCES #OCC := *OCCURRENCE(#ARR) DISPLAY #OCC #ARR(1:#OCC) /* /* Occurrences: 3 Array(*): 'text1', 'text2', 'text3' /* Occurrences: 2 Array(*): 'text4', 'text5' END-WORK * END
Page 1 11-07-15 09:36:13 #OCC #ARR ----------- ------ 3 text1 text2 text3 2 text4 text5
** Example 'RWFEX5': READ WORK FILE - Unformatted with X-array ** and ADJUST its occurrences ************************************************************************ DEFINE DATA LOCAL 1 #ARR (A6/1:*) 1 #OCC (I4) END-DEFINE * DEFINE WORK FILE 1 TYPE 'UNFORMATTED' * WRITE WORK FILE 1 VARIABLE 'text1 text2 text3 ' WRITE WORK FILE 1 VARIABLE 'text4 text5' * DEFINE WORK FILE 1 TYPE 'UNFORMATTED' * READ WORK FILE 1 AND SELECT #ARR(*) AND ADJUST OCCURRENCES #OCC := *OCCURRENCE(#ARR) DISPLAY #OCC #ARR(1:#OCC) /* /*Occurrences: 5 Array(*): 'text1', 'text2', 'text3', 'text4', 'text5' END-WORK * END
Page 1 11-07-15 09:41:25 #OCC #ARR ----------- ------ 5 text1 text2 text3 text4 text5
** Example 'RWFEX6': READ WORK FILE - with numeric CONST variable as ** work file number ** see similar example RWFEX5 with numeric constant ************************************************************************ DEFINE DATA LOCAL 1 #ARR (A6/1:*) 1 #OCC (I4) 1 #WF-1 (N4) CONST<1> END-DEFINE * DEFINE WORK FILE #WF-1 TYPE 'UNFORMATTED' * WRITE WORK FILE #WF-1 VARIABLE 'text1 text2 text3 ' WRITE WORK FILE #WF-1 VARIABLE 'text4 text5' * DEFINE WORK FILE #WF-1 TYPE 'UNFORMATTED' * READ WORK FILE #WF-1 AND SELECT #ARR(*) AND ADJUST OCCURRENCES #OCC := *OCCURRENCE(#ARR) DISPLAY #OCC #ARR(1:#OCC) /* /*Occurrences: 5 Array(*): 'text1', 'text2', 'text3', 'text4', 'text5' END-WORK * END
Page 1 21-12-20 17:42:43 #OCC #ARR ----------- ------ 5 text1 text2 text3 text4 text5