To modify an existing output condition
Type M
in the line command input field of
the selected condition in the Output Conditions window.
The Output Condition Modification window opens with the current values of the conditions.
The Output Condition Modification and Addition windows have the identical layout. The input fields are explained above under Field Descriptions: Output Condition Addition/Modification.
Modify the values.
Press PF3 (End) to save the new definition and return to the Output Conditions window.
Note:
After you add or modify an output condition definition, a loop
check is performed on the affected network. The same conditions apply as
described in the subsection Checking
for a Loop in a Job Network in the section
Network Maintenance with one
exception: if a loop is detected in the job flow, no corresponding message
appears.