This document covers the following topics:
If you want to display or enter Unicode data, the following possibilities exist:
When working in the local development environment with Natural for Windows, all Unicode characters can be displayed and entered in the Natural output window.
When working in a remote development environment with Natural for Windows (SPoD), the Natural Web I/O Interface client (see below) is necessary for displaying and entering all Unicode characters.
When running applications with Natural for UNIX, Natural for OpenVMS, Natural for Mainframes or Natural for Windows, see Natural Web I/O Interface Client below.
Notes:
CPCVERR
                           is ON. 
                  If you run Natural via a terminal emulation or a mainframe terminal such
                       as IBM 3270/3279, the page will be converted to the default code page (value of
                       the system variable *CODEPAGE)
                       before displaying it, so that all characters which are not contained in the
                       default code page are replaced with the substitution character. Equally, input
                       is only possible in code page format and will be converted to Unicode format
                       before assigning it to a U format field. You have to regard that the
                       substitution character is defined by the ICU conversion tables. Depending on
                       this character, it is possible that garbage is displayed with a terminal
                       emulation. On UNIX and OpenVMS platforms, you can change
                       this substitution character by setting the profile parameter
                       SUBCHAR.
                       However, it is strongly recommended that you use the Natural Web I/O
                       Interface when displaying characters not contained in the default code page.
                       When running a remote Windows session, the Natural Web
                       I/O Interface will be used in any case. 
               
On code page oriented mainframe terminals, it is important to select the suitable code page. The default code page of Natural, the code page of the terminal and even the font used by the terminal determine the capability of displaying certain characters correctly.
The Natural Web I/O Interface client is used to display non-GUI information which contains Unicode characters. It can be used in the following environments:
The Natural Web I/O Interface client can be invoked when you use Natural for Windows and you are working with Natural Studio in a remote development environment (SPoD); see Natural Web I/O Interface Client in Remote Development Using SPoD which is part of the Natural for Windows documentation.
When the Natural Web I/O Interface client is used, the Web I/O window appears instead of the terminal emulation window which is not Unicode-enabled in remote UNIX, OpenVMS or mainframe environments, or instead of the output window in remote Windows environments.
The following graphic shows the SPoD environment for Unicode applications with Natural Development Servers (NDV) on UNIX, OpenVMS and mainframes:

So that the Natural Web I/O Interface client can be invoked, the Natural Development Server has to be configured as follows:
UNIX and OpenVMS
If you want to use the Natural Web I/O Interface client in a remote
                                UNIX or OpenVMS environment, the profile parameter
                                WEBIO must be set to
                                ON on the NDV server. See
                                Configuration
                                   Utility in the Natural for UNIX or Natural for OpenVMS
                                documentation.
                     
Mainframe
If you want to use the Natural Web I/O Interface client in a remote
                                mainframe environment, the NDV configuration parameter
                                TERMINAL_EMULATION must be set to WEBIO on
                                the NDV server. See NDV Configuration Parameters in the
                                Natural Development Server documentation. The Natural profile parameter
                                TMODEL can be used to determine the
                                user screen size.
                     
Windows
In a remote Windows environment, the Natural Web I/O Interface client
                                is always used, regardless of the setting of the profile parameter
                                WEBIO. 
                     
The Natural Web I/O Interface client appears when running applications with Natural. It runs in a web/application server.
The following graphic shows the runtime environment for Unicode applications:

Natural recognizes automatically whether the session has been started from the Natural Web I/O Interface client or from the terminal emulation.
Prerequisites for using the Natural Web I/O Interface client:
Natural for UNIX and Natural for OpenVMS
It is required that the Natural Web I/O Interface server (which is
                                 implemented as a daemon) has been installed and activated. See
                                 Natural Web I/O
                                    Interface in the Natural for UNIX and in the Natural for
                                 OpenVMS documentation.
                     
Natural for Windows
It is required that the Natural Web I/O Interface server (which is
                                 implemented as a service) has been installed and activated. See
                                 Natural Web I/O
                                    Interface in the Natural for Windows documentation.