This document covers the following topics:
Some languages, for example Arabic and Hebrew, are written from right-to-left (RTL), whereas the majority of the languages, for example English and German, are written from left-to-right (LTR). Text which contains both left-to-right and right-to-left characters is called bidirectional text.
Natural provides a basic support for bidirectional languages. On Windows, this support is activated when both the Natural default code page and the Windows system code page are defined as bidirectional code pages. If Natural does not define a specific code page, it is sufficient when a bidirectional Windows system code page has been defined. On UNIX and OpenVMS, the support for bidirectional languages is activated when the Natural default code page is a bidirectional code page.
The output of Natural programs can be controlled using the profile
                       parameter PM, the
                       terminal command %V, and the session
                       parameter PM. 
               
On UNIX and OpenVMS, the profile parameter
                       DO (Display Order) is
                       additionally used to support applications that have been originally written for
                       terminals which support inverse (right-to-left) print mode, but no
                       bidirectional data. These applications create the display order of
                       bidirectional data in the application code. With the parameter
                       DO, these applications are enabled to run compatibly
                       also with I/O devices that support bidirectional data. This is for instance the
                       case if an application runs in a browser with the Natural Web I/O
                       Interface.
               
The profile parameter PM defines the default
                       screen direction. When PM is set to R
                       (reset), the default screen direction is left-to-right. When
                       PM is set to I (inverse), the default
                       screen direction is right-to-left. All non-alphanumeric fields and system variables are automatically inverted by Natural
                  so
                       that they are displayed correctly from right-to-left if the screen direction is
                       right-to-left. PF key lines (UNIX and OpenVMS) are not
                       inverted; they are always shown from left-to-right. 
               
The terminal command %V can be used to change
                       the screen direction. If the screen direction is right-to-left, the layout of
                       the current window is mirrored, which means that the origin of all window
                       components or fields is the upper right corner. The screen direction is changed
                       to right-to-left using %VON and is reverted to
                       left-to-right using %VOFF. 
               
The session parameter PM reverses the direction
                       of a field. The effect of "reversing the direction of a field"
                       depends on the statement in which the PM parameter is
                       used and the platform. If the PM parameter is used in a
                       MOVE statement, the content of the field is simply reversed (that
                       is, the first character will become the last character, and so on); the result
                       does not depend on the characters of the field. Trailing blanks are removed
                       before the field is reversed. 
               
For example, the following program
DEFINE DATA LOCAL 1 TEST1 (A10) 1 TEST2 (A10) END-DEFINE TEST1 := 'program' MOVE TEST1 (PM=I) TO TEST2 INPUT TEST1 (AD=O) TEST2 (AD=O) END
produces the following output:
TEST1 program TEST2 margorp
where "margorp" is the reversed version of "program".
When the PM parameter is used for IO statements
                       such as INPUT or DISPLAY, its effect is even more
                       complex. In this case, the field direction is based on the screen direction:
                       
               
If the screen direction is left-to-right and PM=I is
                               applied to a field, the field direction changes to right-to-left.
                     
If the screen direction is right-to-left and PM=I is
                               applied to a field, the field direction changes to left-to-right.
                     
On Windows and browser terminals (Natural Web I/O Interface), "reversing the field direction" does not mean that the characters of the field are simply reversed. Instead, the complex bidirectional algorithm is applied (for more information, see the Microsoft Windows documentation). On character-oriented terminals, however, the characters of a field are not resorted; they are simply reversed.
In the following example, the characters assigned to the variable
                       TEST have been entered in the following sequence:
               
![]()
The following is an example program for Windows. The characters of the constant are already resorted when entering them in the program editor.
DEFINE DATA LOCAL 1 TEST (A20) END-DEFINE TEST := 'abc 123' SET CONTROL 'voff' INPUT TEST (AD=O) / TEST (AD=O PM=I) SET CONTROL 'von' INPUT TEST (AD=O) / TEST (AD=O PM=I) END
This program produces the following two screens on Windows:
TEST abc 123TEST 123
abc
and
123abc TEST abc 123
TEST
The following is an example program for UNIX and OpenVMS. If the characters are entered in the sequence as described above, the program is displayed in the following way, because the characters are simply displayed in the keying sequence.
DEFINE DATA LOCAL 1 TEST (A20) END-DEFINE TEST := 'abc123' SET CONTROL 'voff' INPUT TEST (AD=O) / TEST (AD=O PM=I) SET CONTROL 'von' INPUT TEST (AD=O) / TEST (AD=O PM=I) END
On UNIX and OpenVMS, this program produces the following two screens:
TEST abc123 TEST 321
cba
and
321cba TSET abc
123 TSET
On Windows, UNIX and OpenVMS, the map editor simplifies the handling of maps with bidirectional fields by offering the command. This command changes the display direction of the current map. The position of the fields is not changed; only the view is changed. On Windows, this command applies only to the current map. On UNIX and OpenVMS, a flag is set so that all following maps are displayed reversed; a following command will restore the original situation.
On Windows, the output of
                       dialogs can be
                       controlled in a similar way: both the dialog itself and most of the dialog
                       controls offer an RTL attribute. If the
                       RTL attribute of the dialog is checked, the
                       screen direction of the dialog is right-to-left. If the
                       RTL attribute of other controls is checked, the
                       direction of these controls is right-to-left. 
               
The profile parameter PM defines the default
                       setting of the RTL attribute for new dialogs.
                       When PM is set to R (reset), the
                       RTL attribute is unchecked by default. When
                       PM is set to I (inverse), the
                       RTL attribute is checked by default. The default
                       setting of the RTL attribute for newly created
                       controls of a dialog is derived from the RTL
                       attribute setting of the dialog. 
               
If the RTL attribute of a dialog is
                       changed when the dialog already contains controls, a dialog appears asking
                       whether the RTL attributes of the controls
                       should also be changed. 
               
When working with bidirectional languages on Windows, "GUI" is the preferred print method. With the print method "GUI", the printed page will show the same layout as the window displayed on the screen. The sorting of the field characters is identical.
If the print method "TTY" is used, the printed layout will most probably differ from the layout of the screen window because the field characters are printed in logical sequence. For fields with right-to-left direction, all characters are simply reversed (that is, the first character will become the last character, and so on).
On UNIX and OpenVMS, some special terminal capabilities for bidirectional support can be defined with the Natural Termcap utility.
The key which is defined by the RTLF capability can be used to toggle the input direction of a field at runtime.
With the RTLM and LTRM capabilities, it is possible to switch automatically between right-to-left and left-to-right input mode - provided that the terminal emulation supports this functionality. The RTLM escape sequence will be inserted in front of right-to-left fields, and the LTRM escape sequence will be inserted in front of left-to-right fields.