Version 4.2.5
 —  Natural Advanced Facilities  —

Installing NAF under CICS

This document describes how to install Natural Advanced Facilities (NAF) under CICS.


Prerequisites

For further information, refer to the products and versions specified under Natural and Other Software AG Products and Operating and Teleprocessing Systems Required in the current Natural Release Notes.

Top of page

Installation Tape - z/OS Systems

The installation tape contains the datasets listed in the table below. The sequence of the datasets is shown in the Report of Tape Creation which accompanies the installation tape.

Dataset Name Contents
NAFnnn.LOAD Natural Advanced Facilities executable load phases and modules which are necessary for the linkage editor.
NAFnnn SRCE Natural Advanced Facilities source modules which include macros for specific TP monitors.
NAFnnn.INPL Natural programs including example source programs and system load modules which are necessary for Natural Advanced Facilities.
NAFnnn.SYSF FDT for spool file used as input to Adabas load utility.
NAFnnn.ERRN Natural Advanced Facilities error messages.

The notation nnn in dataset names represents the version number of the product.

Top of page

Installation Tape - z/VSE Systems

The installation tape contains the datasets listed in the table below. The sequence of the datasets is shown in the Report of Tape Creation which accompanies the installation tape.

Dataset Name Contents
NAFnnn.LIBR LIBR backup file.
NAFnnn.INPL Natural programs including example source programs and system load modules which are necessary for Natural Advanced Facilities.
NAFnnn.SYSF FDT for spool file used as input to Adabas load utility.
NAFnnn.ERRN Natural Advanced Facilities error messages.

The notation nnn in dataset names represents the version number of the product.

Top of page

Installation Procedure

This section describes the jobs and steps required to install Natural Advanced Facilities (NAF). They apply to Adabas or VSAM system files.

For installation, use the jobs provided on your Natural tape (names begin with NAF).

Step 1: Modify the CICS RDO Definitions

Job I005

For performance reasons, it is strongly recommended to specify for the spool server a transaction ID which is different from that of the terminal task. It is then possible to dedicate special threads to the spool server.

VSAM System Files

The following additional step applies when using VSAM system files:

Refer to the example job NAFVI005. You can also add DD statements for these datasets to your CICS startup job.

If you want to convert an existing VSAM spool file, the FCT must contain the entries for this spool file. The cluster names of the new and the old versions must be different. The VSAM database ID and file number as well as the VSAM DD-names must be unique.

Step 2: Create/Load the Spool File

Adabas Spool File

Job I050, Step 0300

The following steps only apply when using Adabas system files:

When you upgrade from the previous release of Natural Advanced Facilities, skip this step.

When you upgrade from a release which is older than the previous release, see the section relating to Natural Advanced Facilities migration in the Natural Release Notes.

Load the Natural Advanced Facilities spool file contained in NAFnnn.SYSF by using the ADALOD utility. An initial size of one cylinder for this file will be sufficient. The following parameters are mandatory:

ISNREUSE=YES

to cause Adabas to reuse the ISN of a deleted record. For the file number <fspool>, you may choose any value.

VSAM Spool File

Job I008, Steps 0300 - 0311

The following steps only apply when using VSAM system files.

Step 3: Modify NAFPARMC

Job I055, Step 0305

The use of the NAFPARMC parameter module is optional. Alternatively, to set the server options, you can use Function 30 of the SYSPOOL Application.

If using the NAFPARMC module, modify, assemble and link NARPARMC.

Step 4: Create a Separate Thread Group for Printer Transaction

Jobs I070, I080

It is recommended to establish a separate thread group for the Natural Advanced Facilities printer transaction. To do so, perform these steps:

  1. Modify the Natural/CICS Control Block
    Job I070, Step 2245

    Include a definition of the Natural Advanced Facilities printer thread group into the Natural/CICS control block.

  2. Relink the Modified Natural/CICS Control Block
    Job I070, Step 2250

    Repeat linking of the Natural/CICS control block.

Step 5: Modify NATPARM

Jobs I060, I080

Modify the parameters FSPOOL, NTPRINT, NAFUPF and NAFSIZE in NATPARM according to your site requirements. For more information on these parameters, see NATSPOOL Initialization.

Assemble and link the Natural parameter module NATPARM.

VSAM System Files

The following additional step applies when using VSAM system files:

Step 6: Link the Natural Nucleus

Jobs I060, I080

Add the following INCLUDE statements in the link steps for Natural and link-edit the executable module:

z/OS z/VSE
INCLUDE NAFLIB(NAFAF) INCLUDE NAFAF
INCLUDE NAFLIB(NAFNUC) INCLUDE NAFNUC
INCLUDE SMALIB(NAFPARMC) (optional) INCLUDE NAFPARMC (optional)

Ensure that the Natural module NATTTY is part of your Natural nucleus, since NATTTY enables the Natural Advanced Facilities spool server to send error messages to a printer.

The link-edit of the load module containing Natural Advanced Facilities can be done in any of the following ways:

The following additional step applies when using VSAM system files:

Step 7: Load the System Programs

Job I061, Step 0300

Load the Natural Advanced Facilities system programs into the Natural system file by using the Natural INPL utility. INPL loads the maintenance programs under the application IDs SYSPOOL and SYSPRINT.

Ensure that INPL finishes with the message:

Natural Advanced Facilities initialized by INPL

If this initialization fails, various problems will be encountered at execution time.

This INPL file contains the source for all maps used in the Natural Advanced Facilities system.

These maps are provided in source form to enable users to customize the system (for example, to translate the maps from English to another language).

If these maps are modified, ensure that all fields have the same format/length/relative position in the map. Failure to abide by this restriction will result in an invalid system.

Step 8: Load the Error Messages

Job I061, Step 0304

Load the Natural Advanced Facilities error messages file (dataset NAFnnn.ERRN) by using the ERRLODUS program as described in the Natural SYSERR utility documentation.

Step 9: Natural Advanced Facilities and Natural Security

This step must only be performed, if Natural Advanced Facilities is being installed in a Natural Security environment.

Define SYSPOOL to Natural Security with startup program MENU.

Note:
The physical CICS printers and the application SYSPRINT need not be defined to Natural Security. The Natural Security logon processing will identify the NATSPOOL spool server and perform a simplified logon to SYSPRINT, that is, without any further security checks. In this way, maintenance efforts and the number of Adabas calls at the start of the spool server are considerably reduced. Any logon to SYSPRINT attempted by users other than the NATSPOOL spool server will be rejected by Natural Security, regardless of whether SYSPRINT is defined to it or not.

Step 10: Start Natural

Start Natural and add the user profile, as defined in the NAFUPF parameter of NATPARM, to the SYSPOOL file by using Function 31.1.

Note:
A NAT7201 message is issued at the start of the session indicating that the profile has not yet been added to the SYSPOOL file.

Step 11: Create Sample Conversion JCL

Job I200, Step 0300

When upgrading from Natural Advanced Facilities Version 4.1, skip this step. See Migrating to Natural Advanced Facilities Version 4.2, Case 1, in the Natural Release Notes.

When upgrading from a Natural Advanced Facilities version prior to Version 4.1, you must proceed as described in the section Migrating to Natural Advanced Facilities Version 4.2, Case 2, in the Natural Release Notes.

Step 12: Create NATSPOOL Environment

To initialize a new NATSPOOL environment, see NATSPOOL Initialization.

Step 13: Natural Advanced Facilities and VTAM/SNA

This step must only be performed, if Natural Advanced Facilities is being installed under CICS and is to be used in conjunction with VTAM/SNA printers.

Step 14: Natural Advanced Facilities and VTAM/NON-SNA

This step must only be performed, if Natural Advanced Facilities is being installed under CICS and is to be used in conjunction with VTAM/NON-SNA printers.

Top of page