ESA Console Messages

This document lists the ESA console messages, together with their explanation and the action required.

Message Explanation Action
ESA0001I Parameters for this run:. A subset of the startup parameters will be displayed on the console after this message. No action is required.
ESA0002I :1:. A startup parameter keyword and value pair is displayed. No action is required.
ESA0003I ENTIRE SYSTEMS MANAGEMENT ADAPTER :1: is ready (V: :2:). Node :1: is ready for work now. :2: contains the version number of Entire Systems Management Adapter. No action is required.
ESA0005I ENTIRE SYSTEMS MANAGEMENT ADAPTER :1: stopped. Node :1: has been stopped. No action is required.
ESA0013I :1:. Display Entire Systems Management Adapter user(s) as reponse to operator command USERS. No action is required.
ESA0017I Requested user(s) not found. The operator requested to display/cancel a user who is not active. No action is required.
ESA0073W Invalid command. An invalid operator command was entered. Correct operator command.
ESA0081W User :1: has requested termination. FUNCTION = 'XEND' in view NATPROC-USERS was issued. Entire Systems Management Adapter will terminate now. No action is required.
ESA0100E Bad parm card: :1:. An invalid startup parameter was detected. Correct parameter card.
ESA0298E Entry in table not found. The requested console message was not found in the text table. Contact Software AG.
ESA0299E Error in WTO-routine. An unrecoverable error occurred in console message handler. Contact Software AG.
ESA0305E Invalid value for NUMTASK, SERVER-MIN, SERVER-MAX.

The values specified for the startup parameters mentioned above are not consistent. Please see the section Startup Parameters and section Administration > Entire Systems Management Adapter Features > Dynamic Server Management for a detailed description of these startup parameters and the dependencies between each other.

Correct startup parameter and restart Entire Systems Management Adapter.
ESA0306I SERVER task starting. This message is issued before the Dynamic Server Management tries to create another server [sub]task. No action is required.
ESA0307I SERVER task :1: active. This message is issued after Dynamic Server Management has successfully created another server [sub]task. No action is required.
ESA0308I :1:. Display Entire Systems Management Adapter servers(s) as reponse to operator command SERVERS. No action is required.
ESA0309I Dynamic SERVER management enabled. Dynamic Server Management (DSM) is creating the DSM environment now after detecting start parameter/operator command 'SERVER-DYN=YES'. No action is required.
ESA0310I Dynamic SERVER management disabled. Dynamic Server Management (DSM) is deleting the DSM environment now after detecting start parameter/operator command 'SERVER-DYN=NO. No action is required.
ESA0311I SERVER task :1: stopping. This message is issued before Dynamic Server Management will stop the server [sub]task. No action is required.
ESA0312I SERVER task :1: stopped. This message is issued from the server (sub)task after receiving the stop request from the Dynamic Server Management. The termination processing is running now. No action is required.
ESA0313W Invalid value. The operator command handler has detected an invalid value for a valid operator command. Read the description of the operator command and use a correct value.
ESA0999E Mailer error: :1:. Unrecoverable error occurred during E-Mail processing. See also output file for detailed error description. Consult the network administrator.
ESA2103W Not enough space to create new user entry. The pool of free user control blocks is exhausted. Define a larger number for startup parameter NUMUSER and restart Entire Systems Management Adapter.
ESA2106E No SERVER started. No server could be started. The Entire Systems Management Adapter terminates abnormally. Check startup parameters NUMTASK, JOBSERVER and PRMSERVER.
ESA2107E Internal error during :1: of SERVER task. An internal error has occurred during START or CHECK of a SERVER task. The Entire Systems Management Adapter terminates abnormally if Dynamic Server Management is not running or initialization has not been finished yet. Contact Software AG.
ESA2108E Internal error during CHECK of MAIN task. An internal error has occurred during CHECK of the MAIN task. The SERVER task terminates abnormally due to communication problems with essential parts of the Entire Systems Management Adapter. Contact Software AG.
ESA2109E LOAD for module :1: failed - abend. An error occurred during load (macro BIND) of module :1:. If it is critical, run will terminate. Otherwise, it will continue. Check the file link settings and the module libraries to correct the problem. Restart Entire Systems Management Adapter.
ESA2111E ADABAS MP - Macro :1: RC :2:. Macro :1: has returned the error :2:. The ADABAS memory pool is not accessible. The task terminates abnormally. Contact Software AG.
ESA2116E Macro :1: RC :2:. Macro :1: has returned the error :2:. The task terminates abnormally. Check the :2: return code and contact Software AG if reason of error cannot be solved.
ESA2117E MAIN MP - Macro :1: RC :2:. This error may occur during initialization of Entire Systems Management Adapter. All tasks started from MAIN have to enable the common ESA MAIN memory pool. Macro :1: has returned the error :2:. The task terminates abnormally. Check if all ESA tasks run in the same user account. If not, change the startup parameters. If there is a different problem, contact Software AG.
ESA2118E Interrupt Handler - Macro :1: RC :2:. Macro :1: has returned the error :2:. The interrupt handler of the task cannot work properly. The task terminates abnormally. Check the :2: return code and contact Software AG if problem cannot be solved.
ESA2119E EVENTING MP - Macro :1: RC :2:. Macro :1: has returned the error :2:. The EVENTING memory pool is not accessible. The EVENTING task terminates abnormally. Check the :2: return code and contact Software AG if problem cannot be solved.
ESA2120W TRACE MP - Macro :1: RC :2:. The Macro :1: has returned the error :2:. The TRACE memory pool is not accessible. The TRACE subsystem will be disabled if the error occurs in Entire Systems Management Adapter. If ESATRACE is executing in MONITOR-MODE, the program terminates abnormally. Check the :2: return code and contact Software AG if problem cannot be solved.
ESA2121I CANCEL :1: initiated. This is the response for a successful start of the asynchronous CANCEL processing for the user :1:. No action is required.
ESA2129E Size for EVENTING memory pool is too small. EVENTLEN=12 is the minimum requirement to establish EVENTING. Entire Systems Management Adapter cannot allocate the EVENTING memory pool properly. EVENTING will be disabled for this run of ESA. Set the value of EVENTLEN startup parameter accordingly.
ESA2130E Error during eventing with SERVER task / TSN :1:. MAIN or EVENTING task has detected problems while trying to communicate with a certain SERVER task (TSN :1:). Check the status of the SERVER task and its output file.
ESA2132E Eventing with ADABAS - Macro :1: RC :2:. Entire Systems Management Adapter has detected problems while trying to communicate with the Adabas transport layer. The Macro :1: has returned the error :2:. The task terminates abnormally. Check the :2: return code and contact Software AG if problem cannot be solved.
ESA2133E Eventing with MAIN task - Macro :1: RC :2:. SERVER or EVENTING task have detected problems while trying to communicate with the MAIN task. The Macro :1: has returned the error :2:. The task terminates abnormally. Check the :2: return code and contact Software AG if problem cannot be solved.
ESA2135W :1: during :2: of TRACE :3: file. An error has been detected during function OPEN, WRITE or CLOSE of the TRACE file. :1: contains the error message returned from the operating system. The TRACE environment is disabled. Check the error message and contact Software AG if the problem cannot be solved.
ESA2136E TSN :1: inactive. Entire Systems Management Adapter has detected an inactive task. If the MAIN task is down, the checking SERVER stops also immediately. If a SERVER task is down, Entire Systems Management Adapter will stop if Dynamic Server Management is not active. Otherwise it will try to recover. Check the output file of the inactive task.
ESA2137E Inactive SERVER task detected. Bad status flag for a SERVER task entry detected. Entry will be deleted. Entire Systems Management Adapter will stop if Dynamic Server Management is not active. Otherwise it will try to recover. Contact Software AG.
ESA2138E No active SERVER found. There is no SERVER task available any longer. Entire Systems Management Adapter will stop if Dynamic Server Management is not active. Otherwise it will try to recover. Check the output files of the stopped or abended SERVER tasks.
ESA2139W User :1: - reply in progress by other task. The reply processing for the user :1: cannot continue. An attempt to get the user lock has failed. Another task has already locked the user to create a reply. This concurrency might occur if a user request has been cancelled via operator command or a timeout has been detected. No action is required.
ESA2140I User :1: - throw away old request. The reply processing for the user :1: cannot continue. The ESA ID of the user has been changed while processing the current call. The reply is ignored. No action is required.
ESA2141I SERVER task :1: initialization. The SERVER task notifies of starting the task initialization. No action is required.
ESA2142I SERVER task :1: ready. The SERVER task notifies of successful task initialization. No action is required.
ESA2147E Requested SERVER ID not available anymore. The user session is linked to an abended server. The request cannot continued. Check the output files of the stopped or abended SERVER tasks for abnormal terminations.
ESA2148I No TRACE file written. The TRACE environment is not established. Therefore, no file can be written containing available TRACE data. No action is required.
ESA2149I All buffer elements written to TRACE file. All available TRACE data have been written to the assigned TRACE output file. The TRACE environment will be deleted now. See section Administration > Entire Systems Management Adapter > Creating Trace Data for Diagnostic Purposes on how to proceed with the output file in case of issues.
ESA2150I Empty TRACE file. No valid buffer elements found. The TRACE environment is established. There are no valid data in the TRACE wraparound buffer. Therefore, nothing can be saved to file. This message appears if TRACE environment has been established with startup parameter 'TRACE=PREP' without changing its value in this ESA run. No action is required.
ESA2151W TRACE not prepared. Input ignored. This warning appears if operator wants to change the value of TRACE but the TRACE environment has not been established with 'TRACE=PREP' or 'TRACE=YES'. If the TRACE feature is requested, startup parameter 'TRACE=NO' must be changed to a different value.
ESA2152E PROCESS ABEND CODE :1: PSW :2:. The normal processing of EVENTING or SERVER task has been interrupted to handle a fatal error (STXIT event class ABEND, ERROR, PROCHK). :1: contains the BS2000 interrupt weight. :2: specifies the interrupt address. This is the first message of an information block reporting the status of the task at time of abnormal interruption. Send all diagnostic data (task output files, dump, startup parameter file, TRACE file, command log) to Software AG support.
ESA2153E :1:. This message is part of an information block reporting the values of the general purpose registers at time of abnormal interruption. Send all diagnostic data (task output files, dump, startup parameter file, TRACE file, command log) to Software AG support.
ESA2154E RUNOUT condition detected. The normal processing of EVENTING or SERVER task has been interrupted due to elapsed CPU time limit. The task will terminate. Change the task parameters to unlimited CPU time usage.
ESA2155E STACK FAILURE in function :1:. The internal stack is corrupted. :1: identifies the failed function. Server terminates abnormally. Contact Software AG.
ESA2158E DEFINE CONSOLE EVENT failed with RC :1:. The EVENTING task tried to create an event to handle blocked CONSOLE view requests. This call has returned an error code :1:. Contact Software AG.
ESA2159W Function :1: received invalid POST code :2:. Request ignored. Invalid data has been exchanged between the Entire Systems Management Adapter tasks. The receiving function :1: was not able to determine the requested code. Contact Software AG.
ESA2160E Missing assignment for LINK :1:. The ADD-FILE-LINK statement for LINK-NAME :1: is missing. Add the missing statement in the job control of the requesting task.
ESA2161W TRACE disabled due to errors. This is a follow up message for a TRACE error. Consequently, the TRACE environment is disabled. Check previous console message of the task.
ESA2162E Mismatching ESA version :1: detected. The external programs ESASTOP or ESATRACE cannot interact with the Entire Systems Management Adapter correctly. The unexpected version :1: has been detected which is not compatible to the current version. Use the same version of ESASTOP or ESATRACE as for Entire Systems Management Adapter.
ESA2163E Error in :1: occurred - R15: :2:. Error in UCON interface task occurred in program step :1: (= macro and additional information). Return code of macro is given in :2:. For detailed information, see appropriate BS2000 manuals. Depending on macro and return code.
ESA2164W Data lost. On connection to $CONSOLE one or more message(s) have been lost. (DCAM return code '040014..' for YRECEIVE). No action is required.
ESA2166E :1: abended. The task terminates abnormally. This is a follow up message for a serious error. Task will exit now. Check previous console messages of the task.
ESA2167E :1: serialization - Macro :2: R15 :3:. An error occurred when trying to serialize access to memory pool. Check return code of specified macro and contact Software AG support for more details.
ESA2168E :1: central wait RC :2:. Macro RSOFEI has returned an unrecoverable error. Check return code and output file for more details.
ESA2169W :1: not started. The optional task was not started due to missing startup parameters or due to problems during execution of ENTER. Check startup parameters related to optional task.
ESA2170E :1: is abended with message :2:. ENTER failed. Location of job control or ENTER attributes could be wrong. Check the error message and correct startup parameters and/or job control.
ESA2171E :1: communication error. There were serious errors during interprocess communication with an optional Entire Systems Management Adapter task. The related subsystem will not be available for this run of Entire Systems Management Adapter. Check status and output file of related task for more details.
ESA2172E :1: TSN :2: RPOFEI R15 :3: during shutdown. Macro RPOFEI has returned an unrecoverable error. The requested task couldn't get posted to stop processing and to shut down. Check return code and output file for more details.
ESA2173I :1:. Display Entire Systems Management Adapter response to operator command FILES. No action is required.
ESA2174I Nothing found for this request. There are no data to display for the operator command FILES. No action is required.
ESA2179I :1:. Server statistics on ESA shutdown. No action is required.
ESA2180E :1:. TCP/IP or name resolver errors. Check the error message and contact Software AG if problem cannot be solved.
ESA2181I :1:. Output of Operator command TCPSTAT. No action is required.
ESA2182I :1:. Output of Operator command ABS. No action is required.
ESA4001I Operator typed in: :1:. Message confirming operator input. No action is required.
ESA4004E No option specified. ESA utilities are argument driven. The parameter handler has not found any program arguments or options. The utility will stop immediately. Provide arguments to the program.
ESA4005E Text for DATA-ID exceed OUTPUT. In ESATRACE only: DATA-ID (hard coded text string) does not fit into output area. ESATRACE terminates abnormally. Contact Software AG.
ESA4007E Bad argument value for :1:. The specified value is invalid (e. g. NODE not numeric). Correct argument value.
ESA4008E No output target specified. In ESATRACE only: Option '--NTROUT' has been specified to disable output to file. Option '--DISPL' has not been specified. ESATRACE cannot create output data at all and terminates immediately. At least one output target has to be defined to run ESATRACE correctly. Add option value.
ESA4009E Invalid option specified. ESA utilities are argument driven. The parameter handler has detected an invalid option which cannot be processed. The utility will stop immediately. Correct option value.