3271 Device Support

Overview of Messages

ZA40001 | ZA40002 | ZA40003 | ZA40004 | ZA40005 | ZA40006 | ZA40007 | ZA40008 | ZA40009 | ZA40010 | ZA40011 | ZA40012 | ZA40013 | ZA40014 | ZA40015 | ZA40016 | ZA40017 | ZA40018 | ZA40019 | ZA40030 | ZA40031 | ZA40032 | ZA40033 | ZA40034 | ZA40035 | ZA40036 | ZA40037 | ZA40038 | ZA40039 | ZA40040

ZA40001 LID=$1, TID=$2. WACK SENT BECAUSE NO BUFFER AVAILABLE
Explanation:

This message is associated with the Com-plete 3271 device module. It appears when an input block was received in the permanent input buffer and the 'get small buffer' request that was issued to obtain a buffer for the block failed.

System action:

A WACK (WAIT-ACKNOWLEDGE) is issued. Normal processing continues. The hardware will automatically recover.

System programmer info:

If this message continues to appear, the size of the buffer pool may need to be increased.

Computer operator info:

Notify the Com-plete system programmer if this message appears frequently.


ZA40002 LID=$1, TID=$2. CSWSTAT=$3,SENSE=$4,CCWOP=$5,LIBOP=$6.
Explanation:

This message is associated with the Com-plete 3271 device module. It appears when a UNIT CHECK was received.

System action:

Normal processing continues. A specific poll to LID xxx, TID yyy is issued to obtain error status information.

System programmer info:

This is a probable hardware error.

Computer operator info:

Notify the Com-plete system programmer.


ZA40003 LID=$1, TID=$2. WACK RECEIVED.
Explanation:

Self-explanatory message.


ZA40004 LID=$1, TID=$2. INVALID RESPONSE TO WRITE CONTINUE.
Explanation:

This message is associated with the Com-plete 3271 device module. It appears when a response other than ACK1, WACK or NAK was received in response to a WRITE CONTINUE instruction.

System action:

A specific poll to LID xxx, TID yyy is issued to obtain error status information. Normal processing continues.

System programmer info:

Refer to the appropriate hardware manual for the 3271 control unit for information about the specific poll.

Computer operator info:

Notify the Com-plete system programmer.


ZA40005 LID=$1, TID=$2. RESPONSE TO WRITE SELECT IS NOT ACK0.
Explanation:

This message is associated with the Com-plete 3271 device module. It appears when the response from a WRITE SELECT was not positive.

System action:

The write is retried. If this error occurs 3 times, a return code 12 is given to the application program. Normal processing continues.

System programmer info:

This is a probable hardware error.

Computer operator info:

Notify the Com-plete system programmer.


ZA40006 LID=$1, TID=$2. UNIT CHECK ON READ CONTINUE
Explanation:

This message is associated with the Com-plete 3271 device module. It appears when a READ CONTINUE channel program terminated with a unit check.

System action:

A specific poll to LID xxx, TID yyy is issued to obtain error status information. Normal processing continues.

System programmer info:

Refer to the appropriate hardware manual for the 3271 control unit for information about the specific poll.

Computer operator info:

Notify the Com-plete system programmer.


ZA40007 LID=$1, TID=$2. UNIT CHECK ON WRITE.
Explanation:

This message is associated with the Com-plete 3271 device module. It appears when a WRITE channel program terminated with a unit check.

System action:

The TIBMPERR bit in the TIB associated with TID=yyy is turned on to report the output failure. A specific poll to LID xxx, TID yyy is issued to obtain error status information. Normal processing continues.

System programmer info:

Refer to the appropriate hardware manual for the 3271 control unit for information about the specific poll.

Computer operator info:

Notify the Com-plete system programmer.


ZA40008 LID=$1, TID=$2. ENQ RECEIVED.
Explanation:

This message is associated with Com-plete's remote 3270 device support. It appears when an input block ended with an ENQ character.

System action:

Com-plete writes a NAK to the device and issues a specific poll to obtain sense and status information from the terminal. The sense and status information is logged and normal processing continues.

System programmer info:

This message should be followed by another message that indicates the sense and status information received in response to Com-plete's s the specific poll. This message is useful in obtaining more specific information about the error. For information on the meaning of the sense and status bytes, refer to the appropriate hardware manual for the 3271 control unit.

Computer operator info:

A remote 3270 normally sends an ENQ character to indicate that the TCU has detected a parity error or cursor check on one of its terminals. These errors are usually temporary and recovery should be successful; however, if this message continues to appear, notify the Com-plete ccess system programmer.


ZA40009 LID=$1, TID=$2. BCC ERROR. UNIT EXCEPTION WITHOUT EOT
Explanation:

This message is associated with the Com-plete 3271 device module. It appears when the byte count character received by the transmission control unit did not agree with the number of characters actually received.

System action:

The input is retried three times. After four failures, a specific poll to LID xxx TID yyy is issued to obtain error status information. Normal processing continues.

System programmer info:

Refer to the appropriate hardware manual for the 3271 control unit for information about the specific poll.

Computer operator info:

Notify the Com-plete system programmer.


ZA40010 LID=$1, TID=$2. TEST REQUEST RECEIVED.
Explanation:

This message is associated with the Com-plete 3271 device module. It appears when the TEST REQUEST key was depressed by a 3271 terminal operator.

System action:

The input is ignored. Normal processing continues.


ZA40011 LID=$1, TID=$2. TIDNOTF,IP=$3.
Explanation:

This message is associated with Com-plete's remote 3270 device support. It appears when input is received from a terminal that is not defined in the LGCB MACRO (TIBTAB) for the line from which the data was received. It also appears when input (other than sense and status) is received from a printer.

The value $1 indicates the LID number of the line from which the input data was received.

The value $2 is the TID number of terminal on the control unit from which the input data was received. It is not necessarily the terminal which sent the input data. To determine this, examine the data printed as '$3' (explained below); however, in some situations in a multi-drop environment, the TID can be useful in determining which transmission control unit sent the input data.

System action:

Com-plete reads all of the input, acknowledges receipt of the input, discards the input and continues normal processing.

System programmer info:

This problem is normally caused by an incorrectly defined LGCB or by hardware errors. The ZA40011 message is normally printed when invalid input is received in response to a POLL/READ channel program, in which case, the data printed as '$3' has the following meaning:

  1. Bytes 0 and 1 contain the hexadecimal length of the input data.

  2. If byte 3 contains an SOH (x'01'), then bytes 7 and 8 contain the control unit poll address and device poll address that were sent by the control unit (in response to the POLL channel program).

  3. If byte 3 does not contain an SOH, then bytes 4 and 5 contain the CU and device poll addresses instead of bytes 7 and 8.

Computer operator info:

This message is normally caused by hardware errors that are usually temporary. It is also normal for this message to be issued when remote terminals have recently been installed and have not yet been defined to Com-plete . If this message continues to appear, notify the Com-plete N system programmer.


ZA40012 LID=$1, TID=$2. STATUS MESSAGE-S/S=$3.
Explanation:

This message is associated with the Com-plete 3271 device module. It appears when the sense and status message S/S=z for a 3271 control unit is received. For more information, refer to the appropriate hardware manual for an explanation of the status bytes.

System action:

Normal processing continues.


ZA40013 LID=$1, TID=$2. POLL SUSPENDED BECAUSE THE TERMINAL WAS TURNED OFF
Explanation:

This message is associated with the Com-plete 3271 device module. It appears when three consecutive status messages indicating that intervention is required were received during a specific poll.

System action:

The terminal identified by LID xxx, TID yyy is dropped from the poll list. Normal processing continues.

Computer operator info:

Have TID yyy turned on.


ZA40014 LID=$1, TID=$2. SPECIFIC POLL IS ABOUT TO BE ISSUED
Explanation:

This message is associated with the Com-plete 3271 device module. It appears when a specific poll is about to be issued for LID xxx, TID yyy.

System action:

A specific poll to LID xxx, TID yyy is issued after the ZA400014 message is displayed.


ZA40015 UNIT CHECK ON SELECT FOR READ BUFFER.
Explanation:

This message is associated with the Com-plete 3271 device module. It appears when a unit check condition has been detected while Com-plete is performing a read operation.

System action:

A specific poll will be issued after display of message ZA400014 to identify the terminal in error. Processing continues.


ZA40016 LID=$1, TID=$2. UEX WITHOUT EOT. ATTEMPTING TO CLEAR VIA READ.
Explanation:

This message is associated with the 3271 device module and indicates that a unit exception was received without reading an EOT.

System action:

The device module reads the line to clear it, then resumes the poll of the line.

Computer operator info:

If this method occurs occasionally, it should not cause concern. If it occurs frequently, it indicates a line problem and the line should be checked. This type of line error is usually caused by noise on the line, and the read of the line will eliminate it.


ZA40017 LID=$1, TID=$2. ENABLE FAILED FOR LINE, LINE IGNORED.
Explanation:

This message is associated with the 3271 device module and indicates that the attempt to enable the line has failed.

System action:

The device module sets the line status to IGNORE. A subsequent restart of the line will retry the enable.

System programmer info:

This problem may be caused by the wrong CUU in the TIBTAB definition for the line.

Computer operator info:

If a restart of the line causes the same message, there is probably an error in the hardware or the software definition of the line.


ZA40018 LID=$1, TID=$2, SLOW POLL INITIATED.
Explanation:

This message is associated with the 3271 device module and indicates that the device module received an excessive number of timeouts from the control unit for TID nnn.

System action:

The device module polls the control unit for TID nnn every two minutes until the timeouts stop. All TIDS on the same control unit are affected.

Computer operator info:

This message is frequently associated with a control unit that is turned off. If this is the case, when the control unit is turned on, normal polling will resume after two minute delay.


ZA40019 LID=$1, TID=$2. EXCESSIVE INPUT. ATTEMPTING TO CLEAR VIA READ.
Explanation:

This message is associated with the 3271 device module. It appears when an excessive input exceeded internal buffers' capacity.

System action:

Com-plete reads the line in an attempt to clear it, then resumes the poll of the line.

Computer operator info:

There is probably an error in the hardware.


ZA40030 TPDMINIT ENTRY FOR LIB WHEN LINE ALREADY RUNNING
Explanation:

This message is associated with the Com-plete 3271 device module. It appears when the TLAM3271 module was entered at the TPDMINIT entry point and LIB was passed in RTIB. The LIBOPER field in the LIB indicated that the line had already been initialized.

System action:

Normal processing continues.

System programmer info:

This message indicates a logic error in the device support for remote 3270s. Notify Com-plete technical support of this error condition.

Computer operator info:

Notify the Com-plete system programmer.


ZA40031 TPDMENIN ENTRY FOR LIB WHEN LINE ALREADY RUNNING
Explanation:

This message is associated with the Com-plete 3271 device module. It appears when the TLAM3271 module was entered at TPDMENIN entry point and a LIB was passed in RTIB. TPDMENIN is an invalid entry point for LIBs.

System action:

Normal processing continues.

System programmer info:

This message indicates a logic error in the device supprot for remote 3270s. Notify Com-plete technical support of this error condition.

Computer operator info:

Notify the Com-plete system programmer.


ZA40032 TPDMWRIT ENTRY FOR LIB
Explanation:

This message is associated with the Com-plete 3271 device module. It appears when TLAM3271 was entered at the TPDMWRIT entry point and a LIB was passed in RTIB. TPDMWRIT is an invalid entry point for LIBs.

System action:

Normal processing continues.

System programmer info:

This message indicates a logic error in the device support for remote 3270s. Notify Com-plete technical support of this error condition.

Computer operator info:

Notify the Com-plete system programmer.


ZA40033 TPDMWRIT ENTRY WHEN TIBMII IS OFF (INPUT NOT INHIBITED)
Explanation:

This message is associated with the Com-plete 3271 device module. It appears when a TIB was passed to the TLAM3271 module at the TPDMWRIT entry point and the TIBMII bit was off.

System action:

Normal processing continues.

System programmer info:

This message indicates a logic error in the device support for remote 3270s. Notify Com-plete technical support of this error condition.

Computer operator info:

Notify the Com-plete system programmer.


ZA40034 TPDMWRIT ENTRY WHEN TID NOT FOUND IN LGCB TIDLIST
Explanation:

This message is associated with the Com-plete 3271 device module. It appears when a TIB was passed to the TLAM3271 module at the TPDMWRIT entry point, and a corresponding TID could not be found in the LGCB TIDLIST.

System action:

Normal processing continues.

System programmer info:

This message indicates a logic error in the device supprot for remote 3270s. Notify Com-plete technical support of this error condition.

Computer operator info:

Notify the Com-plete system programmer.


ZA40035 TPDMWRIT ENTRY WHEN WRITE ALREADY QUEUED OR IN PROGRESS
Explanation:

This message is associated with the Com-plete 3271 device module. It appears when a TIB was passed to the TLAM3271 module at the TPDMWRIT entry point, and the TIDLIST entry indicated that a write operation had either already been queued or was already in progress.

System action:

Normal processing continues.

System programmer info:

Notify Com-plete technical support of this error condition.

Computer operator info:

Notify the Com-plete system programmer.


ZA40036 TPDMCMPL ENTRY FOR LIB INPUT: DEVAD TIBMTDEL=0, TIBMII=0, BUFNO=0
Explanation:

This message is associated with the Com-plete 3271 device module. It appears when a LIB was passed to the TLAM3271 module at the TPDMCMPL entry point, and the associated TIB in the LGCB TIDLIST was not deleted, did not have the TIBMII bit on, and did not have a TIBBUFNO of zero.

System action:

Normal processing continues.

System programmer info:

This message indicates a logic error in the device supprot for remote 3270s. Notify Com-plete technical support of this error condition.

Computer operator info:

Notify the Com-plete system programmer.


ZA40037 TPDMCMPL ENTRY FOR LIB INPUT: LAST CHAR NOT ETX OR ETB
Explanation:

This message is associated with the Com-plete 3271 device module. It appears when the last character of input received was neither ETX nor ETB.

System action:

The input is processed as though an ETX had been received.

System programmer info:

Notify Com-plete technical support of this error condition.

Computer operator info:

Notify the Com-plete system programmer.


ZA40038 TPDMCMPL ENTRY FOR LIB INPUT: EOT RECEIVED BEFORE EXPECTED ETX
Explanation:

This message is associated with the Com-plete 3271 device module. It appears when an EOT was received without a preceding ETX.

System action:

Normal processing continues.

System programmer info:

Notify Com-plete technical support of this error condition.

Computer operator info:

Notify the Com-plete system programmer.


ZA40039 TPDMCMPL ENTRY FOR TIB INPUT: UNABLE TO GET SMALL BUFFERS FOR INPUT
Explanation:

This message is associated with the Com-plete 3271 device module. It appears when an input TIB was passed to the TLAM3271 module at the TPDMCMPL entry point and Com-plete was unable to allocate a buffer for input.

System action:

Normal processing continues.

Computer operator info:

Notify the Com-plete system programmer.


ZA40040 TPDMENIN ENTRY FOR TIB NOT FOUND IN LGCB TIDLIST
Explanation:

This message is associated with the Com-plete 3271 device module. It appears when a TIB was passed to the TLAM3271 module at the TPDMENIN entry point but its corresponding TID was not found in the LGCB TIDLIST.

System action:

Normal processing continues.

System programmer info:

This message indicates a logic error in the device support for remote 3270s. Notify Com-plete technical support of this error condition.

Computer operator info:

Notify the Com-plete system programmer.