ZA10002 |
Permanent error - Tid $1 - Sense $2 - Output |
Explanation: |
This message is associated with the Com-plete 2740 device module. It
appears when four successive hardware errors have occurred while Com-plete was
attempting to write to TID $1.
|
System action: |
If TID $1 was in conversation with a program when the errors occurred,
control is passed to the program at the point immediately following the WRITE
instruction and a return code of 12 is set. If the write operation was not a
conversational write but was performed at the request of a user program,
Com-plete attempts to write the ZAM00012 message and aborts the output that was
to be written.
|
System programmer info: |
The value $2 is the hardware sense information describing the error.
The bit settings are as follows: bit 0 - command reject bit 1 - intervention
required bit 2 - bus out check bit 3 - equipment check bit 4 - data check bit 5
- overrun bit 6 - lost data (BID key) bit 7 - timeout
|
Computer operator info: |
Seek the assistance of the Com-plete system programmer. If the message
continues to appear, it may be necessary to place the terminal indicated by TID
$1 on IGNORE status until the problem can be determined.
|