UQ Operator Command Processing

Overview of Messages

UQK0001 | UQK0002 | UQK0003 | UQK0004 | UQK0005 | UQK0006 | UQK0007

UQK0001 Security error
Explanation:

This message is associated with the Com-plete online utility UQ. It indicates that the terminal operator has attempted to enter a K function but was not authorized for this function.

System action:

The requested function is ignored.

Terminal operator info:

The appearance of this message indicates that the user ID in use is not authorized to issue the function requested. On systems using the logon feature of Com-plete , this means that the user ID used was not assigned control status. On systems not using the logon feature, this means that the terminal in use has not been assigned control status. Contact the Com-plete system programmer.

System programmer info:

When adding a user via ULOGM control status may be assigned to a user. If the logon feature is not in use, control status is assigned by the TIB macro in the TIBTAB. For more informations on these items, refer to the Com-plete System Utilities Manual.


UQK0002 No room for command
Explanation:

This message is associated with the Com-plete online utility UQ. The terminal operator has requested that a command be sent to the JES3 global system for processing; however, there is no room for the command in the JES3 file.

System action:

The request is not processed.

Terminal operator info:

Wait a few moments to allow other pending commands to be processed, then retry. If the error persists, contact the Com-plete system programmer.

System programmer info:

Ensure the JES3 DSP UQJ3 is functioning on the JES3 global processor.


UQK0003 I/O error on command data set
Explanation:

This message is associated with the Com-plete online utility UQ. The terminal operator has requested that a command be sent to the JES3 global system for processing; however, an I/O error occurred while attempting to process the command.

System action:

The request is not processed. Further attempts to send the command will receive message UQZ0003.

Terminal operator info:

The command cannot be sent.

System programmer info:

This is a probable hardware error. If the JES3 data set remains unusable, it will be necessary to reallocate the JES3 data set.


UQK0004 Async. OC task not installed
Explanation:

Self-explanatory message.


UQK0005 A command is already in progress / async. OC task busy. Try later.
Explanation:

Self-explanatory message.


UQK0006 Input is rejected. The REPLY ID does not match any pending message.
Explanation:

Self-explanatory message.


UQK0007 Invalid input. Register 0 contains a non-zero value.
Explanation: