When the Natural Optimizer has been activated, you can specify checks by setting the options explained in this section.
The options cannot be used for specifying statements to be optimized.
This document covers the following topics:
The following table lists and describes the Natural Optimizer Compiler options. Default values are underlined (this is the value that will be assumed if the option is not present).
A Natural Optimizer Compiler option consists of a string surrounded by brackets or
single quotation marks (except in the Natural OPTIONS statement), with options separated by commas. Some
options have values, while the very existence of some options in the option string is
sufficient to modify the environment.
The following rules apply:
Optional clauses are surrounded by square brackets [ ].
Choices are surrounded by curly braces { }.
Each choice is separated by vertical lines "|".
Only one of these choices can be specified;
ON is equivalent to Y (Yes),
OFF to N (No).
Options specified without the optional clause ON or OFF
(if applicable), or their equivalent values, are interpreted as set to
ON. For example, OVFLW is identical to
OVFLW=ON.
Except for the option OFF, any specified option switches on optimizing
(as if ON was specified) and the default values apply. For example,
INDEX is identical to ON,INDEX.
| Option | Explanation |
|---|---|
ABEND |
Forces the Natural Optimizer Compiler to generate code which causes Natural
to be abnormally terminated immediately when the ABEND option is
encountered by the Natural Optimizer Compiler during compilation. The option
must appear by itself or it will be ignored. Other parameters are not changed or
reset by this option. This option can be useful for debugging purposes.
|
ARCH |
Specifies the architecture level to be used for code generation. For more information, see ARCH Option in the following section. |
ARROPT |
Specifies the generation to be used for array assignments of the type A(*):=scalar. For more information, see ARROPT Option in the following section. |
CACHE[={ON| OFF
|Y|N}] |
Switches variable caching on or off. See also Variable Caching in the section Performance Considerations. |
CPU= /370 |
Specifies the target architecture. |
DIGTCHCK[={ON| OFF
|Y|N}] |
Specifies whether the digits of packed and
unpacked numeric fields (formats P and N) are to be checked when moving to
another variable of the same type and precision. For example, if DIGTCHCK is ON and an unpacked numeric
variable (format N) contains an invalid digit, such as X'FA',
moving to another unpacked numeric variable with the same precision will
generate a S0C7 (or NAT0954) error. If
DIGTCHCK is OFF, no error is generated but the
generated code is much faster.
|
ERRDUMP[={ON| OFF
|Y|N}] |
Specifies whether NOC should abend if an error condition is detected during the compile phase. This is useful for debugging the Natural Optimizer Compiler itself. |
INDEX[={ON| OFF
|Y|N}] |
Specifies whether array indexes will be checked for out-of-bound values in
the optimized code.
See also the following Note. |
INDX[={ON| OFF
|Y|N}] |
Specifies whether array indexes will be checked for out-of-bound values in
the optimized code.
Additionally, See also the following Note. |
IO[={ON| OFF|Y|N}] |
Provided for compatibility reasons only. No effect. |
LOOPS[={ON| OFF
|Y|N}] |
Provided for compatibility reasons only. No effect. |
MIX[={ON| OFF
|Y|N}] |
Provided for compatibility reasons only. No effect. |
NODBG[={ON|
OFF|Y|N}] |
If NODBG=OFF/N (default), the Natural Debugger can be used to
debug optimized code (then, additional code is generated to check whether
TEST mode has been set on).
If See also |
NOSGNTR[={ON| OFF
|Y|N}] |
Applies to packed numbers only.
If |
ON |
Switches on optimizing. If no additional option is specified, the default
value defined for each option is in effect. As indicated in the following
Note, this
may cause unintended results, in particular regarding the options INDEX,
INDX, OVFLW, and RANGE.
|
OFF |
Switches off optimizing. |
OPTLEV={ 2|3} |
Specifies optimization level - roughly equivalent to the number of passes
through the program.
|
OVFLW[={ON| OFF
|Y|N}] |
Specifies whether checks for overflow in arithmetic operations or
assignments will be included in the optimized code.
See also the following Note. |
PGEN[={ON| OFF
|Y|N}] |
Specifies whether a disassembly of the optimized code should be output. This option also enables all other tracing options: see PGEN Option in the following section. |
RANGE[={ON| OFF
|Y|N}] |
Specifies whether range checks will be performed in operations with arrays.
This ensures that array ranges will have an equal number of elements in
corresponding dimensions of all operands.
See also the following Note. |
SIGNCHCK[={ ON|OFF|Y|N}] |
Specifies whether the result of a multiplication with a packed or unpacked
numeric multiplier should be checked for a negative zero. If zero is multiplied
by a negative number, the MP machine instruction generates a negative zero
result. If SIGNCHCK is on, this negative zero is converted to a
positive zero. The check for a negative zero is done for every multiplication
with a packed or unpacked numeric multiplier.
|
TRENTRY |
For internal use only. Do not change the setting of this parameter. |
UNICC |
Specifies whether the optimized code is generated for IF and DECIDE statements with Unicode operands. For more information, see UNICC Option in the following section. |
ZD[={ ON|OFF|Y|N}] |
Specifies whether divisors should be checked for zero. If this option is
specified, then code is inserted, so that the program behaves according to the
ZD profile
parameter of Natural, that is, Natural error NAT1302 is issued or
the result is zero. If this option is not specified, Natural error
NAT0954 occurs if the divisor is zero.
See also ZD - Zero-Division Check in the Natural Parameter Reference documentation. |
Note for INDEX, INDX, OVFLW and RANGE:
If the option INDEX, INDX, OVFLW or
RANGE is set, extra instructions are added to the generated code to
detect data overflow and index-out-of-range situations should they occur during program
execution. Although the use of these options slightly increases the generated code, we
recommend to use them to guarantee that erroneous programs are detected and cannot lead
to unpredictable results, storage corruptions or abnormal program terminations.
Below is information on:
DEFINE DATA LOCAL ... 1 P1 (P1/9) ... 1 P3 (P3/9) ... 1 I (I4) 1 J (I4) 1 K (I4) 1 L (I4) END-DEFINE ... P1(I:J) := P3(K:L) ... END
With INDX=ON or INDEX=ON set, code is generated to verify
that I, J, K and L are within the
ranges defined for P1 and P3 respectively.
With INDX=ON or RANGE=ON set, code is generated to verify
that I:J and K:L denote ranges of the same length.
With OVFLW=ON set, code is generated to verify that the value of
P3 fits into the corresponding P1 variable.
For example: Value 100 would cause an overflow here.
Example Error Situation:
If one of the occurrences of P3 contains the value 100,
with OVFLW=OFF set, the value assigned to the corresponding
P1 occurrence will be zero. If the index variable I is
zero or greater than 9, with INDX=OFF set, storage areas
that do not belong to Array P1 will be corrupted. If these options
(OVFLW and INDX) are set to ON, a Natural
error occurs like it does in standard Natural runtime.
For the NOC option specified above, additional code is generated. However, this is well compensated for by the advantage of a check that, for example, protects against hard-to-debug errors. Undetected errors can, of course, lead to unpredictable results.
To assure that the least amount of code is generated and thus achieve optimum performance, use:
OPT='NODBG,NOSGNTR,SIGNCHCK=OFF,ZD=OFF'
However, only apply this setting to objects that have been thoroughly debugged; see also Note for INDEX, INDX, OVFLW and RANGE.
The ARCH option specifies the hardware architecture level to be used for
generating code for executable Natural objects.
When you specify an ARCH value, the Natural Optimizer Compiler generates
newer and faster machine instructions that can improve the performance of the generated
code. You cannot specify a value that is higher than the architecture level of your
current machine. An executable Natural object cataloged with an ARCH level
can only run on a machine with the same or a higher architecture level. Therefore, we
recommend not to use the ARCH option if the cataloged objects are intended
to execute on any machine, especially on a machine with a lower architecture level.
For detailed information on architecture levels, see the related literature from IBM (z/Architecture, Principles of Operation).
The following architecture levels are supported by the ARCH option of the
Natural Optimizer Compiler:
| Architecture Level | IBM Hardware Facility Required |
|---|---|
0 |
Specifies that no architecture level is used. This is the default setting for compatibility with all mainframe platforms supported by Natural. |
1 to 4 |
These values are not evaluated and treated as
ARCH=0.
|
5 to 6 |
|
7 |
|
8 |
|
9 |
|
10 |
|
11 |
|
12 |
|
Note
With an ARCH value greater zero, the Natural Optimizer Compiler
generates instructions up to the facility level described in the table above. An
ARCH value higher than the architecture level of the underlying machine
is rejected at compile time. The attempt to start a program compiled with an
ARCH level on a machine with a lower architecture level, causes a
NAT1394 runtime error. You can display information on the
current machine by using the TECH system command.
This section covers the following topics:
When ARCH=10 is set, the Natural Optimizer Compiler generates
instructions provided by the Decimal-Floating-Point (DFP) Zoned-Conversion Facility
for the numeric operations described in the following section. This can significantly
improve the execution speed for statements that use these operations.
- Operations Optimized by ARCH=10
The following arithmetic operations on variables of the Natural data formats I (integer), N (numeric unpacked) and P (packed numeric) benefit from
ARCH=10:
Value assignments:
P:=I
P:=N
N:=I
N:=N
N:=Ponly if the number of packed digits is less than or equal to 15.
I:=NArithmetic operations, such as
ADD,SUBTRACT,DIVIDEandMULTIPLYstatements, but only if both of the following conditions apply:At least one of the operands used is in the format N or I.
The operation result does not exceed 34 (integer + precision) digits.Comparisons, such as
IFandDECIDEstatements, but only if both of the following conditions apply:At least one of the operands used is in the format N.
Both operands are in different formats.
When ARCH=11 is set, the Natural Optimizer Compiler uses machine
instructions introduced with the DFP Packed-Conversion Facility. In addition to the
numeric operations optimized with ARCH=10, ARCH=11 also optimizes operations
that use packed variables only.
When ARCH=12 is set, the Natural Optimizer Compiler generates machine
instructions newly introduced with the Vector-Packed-Decimal Facility (VPD) in the z14
hardware class. This can improve the execution speed for assignments, comparisons, and
calculations if at least one packed operand is involved.
VPD machine instructions are generated for the same Natural operations described for Architecture Level 11, except they are applied only to arithmetic operations whose results do not exceed 31 (integer + precision) digits.
When ARCH=10 is used, the Natural Optimizer Compiler generates machine
instructions introduced with the Decimal-Floating-Point (DFP) Zoned-Conversion
Facility, DFP Packed-Conversion Facility or the Vector Packed-Decimal Facility (VPD).
These instructions execute faster than the standard machine code instructions for
arithmetic operations, but they do not accept data which is improper in terms of the
zoned numeric data type (N).
This may cause runtime errors, when an N-field is defined within a
REDEFINE section of an alpha or binary variable and the N-field is not
properly initialized before used in an arithmetic operation.
A numeric zoned field carries one digit in one byte. Usually, each byte contains x’F’ in the left halfbyte (Zone bits) and the digit value (0-9) in the right halfbyte (Numeric bits). This applies for all bytes, except for the last one, which contains (A-F) in the left halfbyte (Sign bits).
A sign halfbyte (C,A,F,E) represents a positive value, whereas (B,D) stands for a negative value. A value other than (0-9) inside the numeric halfbytes (N) and a value other than (A-F) inside the sign halfbyte (S) is considered invalid. The data inside the zone halfbytes (Z) is not regarded by arithmetic conversion instructions and can have any value (0-F).
Example for a variable defined as (N6):
| ZN | ZN | ZN | ZN | ZN | SN | Sign is | Value is | Works with ARCH<=9
|
Works with ARCH>=10 |
|---|---|---|---|---|---|---|---|---|---|
| F1 | F2 | F3 | F4 | F5 | F6 | F=positive | 123456, ok | yes | yes |
| F3 | F2 | F6 | F3 | F3 | D2 | D=negative | 323662, ok | yes | yes |
| 40 | 40 | 40 | 40 | 40 | 40 | 4=invalid | 000000, ok | yes | NAT7024 |
| 00 | 00 | 00 | 00 | 00 | 00 | 0=invalid | 000000, ok | yes | NAT7024 |
| 12 | 13 | 14 | 15 | 16 | 17 | 1=invalid | 234567, ok | yes | NAT7024 |
| 51 | 6B | 72 | 7A | 12 | F1 | F=positive | 1B2A21, invalid | NAT0954 | NAT7024 |
When ARCH=9 (or lower) is used, invalid sign halfbytes (0-9) are
automatically corrected by the generated code to a positive sign (F). This turns
N-fields with a blank contents into valid data with value zero. The same applies for
Hexa zero data.
When ARCH=10 (or higher) is used, invalid sign halfbytes (0-9) remain
unchanged and lead to a program check (Data exception) when accessed by a DFP or VPD
instruction. If such an abend occurs, Natural issues a NAT7024 error instead of a NAT0954 to clearly indicate that the error is
caused by an N-variable that does not contain valid numeric data.
If a numeric halfbyte (N) contains a value other than (0-9), a program check (Data exception) happens regardless of the ARCH level used.
Do not use ARCH=10 (or higher) to catalog a program which operates
unclean numeric data, with a sign value other than (A-F).
For example:
OPTIONS MCG=(PGEN,ARCH=9) DEFINE DATA LOCAL 1 #A (A6) 1 REDEFINE #A 2 #N (N6) END-DEFINE /* ARCH=9 ARCH=10 #A := H'F1F2F3F4F5F6' ADD 1 TO #N WRITE #N /* ok ok #A := H'F3F2F6F3F3D2' ADD 1 TO #N WRITE #N /* ok ok #A := H'404040404040' ADD 1 TO #N WRITE #N /* ok NAT7024 #A := H'000000000000' ADD 1 TO #N WRITE #N /* ok NAT7024 #A := H'121314151617' ADD 1 TO #N WRITE #N /* ok NAT7024 #A := H'516B727A12F1' ADD 1 TO #N WRITE #N /* NAT0954 NAT7024 END
Moreover, when ARCH=10 (or higher) is used, Natural can issue a
NAT1305
(truncated numeric value) instead of a NAT1301 error
(intermediate result too large) for the following reason: The DFP or VPD numeric
format is used for calculating intermediate results and an overflow is only detected
at the end of the arithmetic operation when the DFP is converted into the format of
the result.
When ARCH=12 is used, the Natural Optimizer Compiler generates machine
instructions introduced with the Vector Packed-Decimal Facility (VPD) which are
compatible in terms of data incorrectness with the code generated with
ARCH=9 or below.
Numeric data fields (N) with incorrect sign representations (0-9) are converted into the positive sign value (F). This accepts numeric fields with a blank or hex00 content and treats them as value zero. A data exception (abend) does not occur in these cases.
The ARROPT option determines the generation algorithm to be used for array
assignments of the type A(*):=scalar.
Valid values for ARROPT are:
| Value | Explanation |
|---|---|
ON |
Recommended setting for arrays with a minimum of 50
occurrences.
|
OFF |
Recommended setting for arrays with less than 50 occurrences. |
The PGEN option causes the Natural Optimizer Compiler to output the
generated code and internal Natural structures. Thus, code and structures can be
examined, for example, for bug fixing, performance review and support issues.
An understanding of IBM's /370 assembler is required to interpret the results produced
by the PGEN option.
We recommend that you use this option with the assistance of support.
Below is information on:
To use the PGEN facility, set the PGEN option when
activating on the Optimizer Compiler.
Since the buffer is kept in memory, it is possible that the user thread will not be
big enough to hold the trace information. In this case, try setting PGEN
on only for the portion of the program which is to be traced, for example:
OPTIONS MCG=(PGEN=ON,TRGPT=ON)or OPTIONS MCG=+PGEN,TRGPT |
Turns tracing on, including tracing of the GPT entries |
OPTIONS MCG=(PGEN=OFF)or OPTIONS MCG=-PGEN |
Turns tracing off |
Various options affect the content of the output. The basic PGEN option
causes a formatted listing of Natural source lines and a disassembly of the
corresponding code to be generated and kept in memory for extraction by the
NOCSHOW utility as described below, under Output of the PGEN
Option.
The TRSTMT, TRGPT, TRMPT and
TRVDT options cause hex dumps of internal data structures associated
with each line to be output.
The TRBASES and TRCACHE options cause information on base
registers and cache variables to be printed out.
The following table describes the options when PGEN=ON. For an
explanation of the syntax used see the introduction to List of Options above.
| Option | Explanation |
|---|---|
LPP={5|..| 55
|..|255} |
Lines-per-page for the trace output, only used when
TREXT=ON.
|
NOsrcE[={ON| OFF
|Y|N}] |
If NOsrcE=OFF, the Natural source statement is included in
the output.
|
TRACELEV={ 0
|..|255} |
Specifies the trace level. Each bit in this one byte value specifies a
buffer type to trace; these bits can be set on by using the
TRxxx options as well.
|
TRBASES[={ON| OFF
|Y|N}] |
Specifies whether base register allocations are traced. |
TRCACHE[={ON| OFF|Y|N}] |
Specifies whether CACHE entries are traced.
|
TREXT[={ON| OFF
|Y|N}] |
If TREXT=ON, trace is directed to the user exit NOCPRINT as described
below.
|
TRGPT[={ON| OFF
|Y|N}] |
Specifies whether GPT entries are traced.
|
TRMPT[=ON| OFF
|Y|N}] |
Specifies whether MPT entries are traced.
|
TRSTMT[={ON| OFF
|Y|N}] |
Specifies whether STMT entries are traced.
|
TRVDT[={ON| OFF
|Y|N}] |
Specifies whether VDT entries are traced.
|
See also the examples below.
There are two places to where the Natural Optimizer Compiler can direct the output of
PGEN:
The contents of this buffer is overwritten each time a
CHECK, CAT,
STOW or RUN command is
executed. A system utility NOCSHOW is provided whereby the contents of
this buffer can be viewed, searched or printed.
To invoke the NOCSHOW utility
Enter the direct command NOCSHOW after a
CHECK, STOW,
CAT or RUN where the
Natural Optimizer Compiler has been active.
The following PF keys are available on the screen:
| Key | Function |
|---|---|
| PF2 | Position to top of output |
| PF4 | Position one line backward |
| PF5 | Position one line forward |
| PF6 | Print to report (1) |
| PF7 | Position one page backward |
| PF8 | Position one page forward |
| PF9 | Print via Entire Connection to report (7) |
| PF10 | Scan for text string |
| PF11 | Repeat scan |
If TREXT=ON is specified, the Natural Optimizer Compiler passes every
output line to the user exit NOCPRINT instead of adding it to the trace
buffer.
NOCPRINT is invoked following normal OS register conventions. Register
1 points to a full word containing the address of the 81 byte print line with ANSI
carriage control characters in position 1. Register 13 points to an area of 18*4
bytes which may be used as a save area. Register 14 contains the return address and
Register 15 contains the entry address of NOCPRINT.
The user exit NOCPRINT can be written in any language which supports
the register conventions described above. It must be linked to the Natural nucleus
together with the Natural Optimizer Compiler nucleus.
This section provides hints and explanations on how to interpret the output created
with the PGEN option.
At the top of the PGEN output are some disassembled lines which do
not appear to belong to any source line. These are the instructions which make up
the prologue, which is executed whenever control passes from non-optimized to
optimized code. Permanent base registers are loaded and control is passed to the
correct point in the prologue. See Example Section A below.
Sometimes a lot of source lines are printed without any code. This indicates that there was no code required or that these statements are excluded from the NOC optimization. See Example Section B below.
Moreover, when the code generated for a Natural statement consists only of:
BAS R14,RETH DC X'....'
this indicates a return back to the standard runtime, as this statement could not
be NOC optimized (see line 0170).
If the NODBG=OFF (default) has been specified, a sequence of
instructions is generated at the start of each Natural statement:
BALR R9,R11 DC X'....'
This sequence sets the line number (in case of error) and checks whether the
TEST mode is switched ON. Without this sequence,
debugging of NOC-compiled statements by the Natural Debugger is not possible. See
Example Section
C below.
Sometimes there is a line break between disassembled lines. This break indicates an internal statement separation. It happens because often a single Natural statement will generate multiple internal (pseudo-code) statements.
The Natural variables operated are inserted in the Assembler code.
The items on the right side (e.g. “START 8FEC”) are of internal nature. They document the path how the code was generated by the NOC modules.
All kind of addresses inside the code are resolved and provided in the form
“=(00044)”. It documents the offset in the code to which the branch
is executed.
The first and the last code instruction contains the NOC version used to compile
this program. The meaning of “4700 8410” is NOC
V841.
000000 4700 8410 NOP 1040(,R8) START 8FEC
000004 5880 D354 L R8,CONST D9DC
000008 5870 D370 L R7,LOCAL D9DC
00000C 4810 6006 LH R1,6(,R6) 90A0
000010 1F60 SLR R6,R0 90BA
000012 47F1 A000 B 0(R1,R10) 90C0
000016 4DE0 B040 BAS R14,RETH RETN F0AA
00001A 0034 DC X'0034' F0C0
0010 0010 OPTIONS MCG=(PGEN,OVFLW,INDX) 0020 DEFINE DATA LOCAL 0030 1 I(I4) 0040 1 P(P7.2) 0050 1 T(P7.2) 0060 END-DEFINE 0070 * 0080 SETTIME 0090 *
0100 FOR I=1 TO 100000
00001C 0D9B BASR R9,R11 MOVE 1724A
00001E 004A DC X'004A' 17278
000020 D203 7000 8148 MVC I(4),#KST0148 97D2
000026 47F0 A044 B 68(,R10) =(00044) GOTO EF44
00002A 0D9B BASR R9,R11 ADD 1724A
00002C 006A DC X'006A' 17278
00002E BF0F 7000 ICM R0,B'1111',I BB20
000032 5A00 8148 A R0,#KST0148 1E4E
000036 0D90 BASR R9,0 F12A
000038 4710 B15C BO NAT1301 1E9E
00003C BE0F 7000 STCM R0,B'1111',I A9CC
000040 0D9B BASR R9,R11 IF 1724A
000042 007C DC X'007C' 17278
000044 BF0F 7000 ICM R0,B'1111',I BB20
000048 5900 819B C R0,#KST019B 3FDA
00004C 47D0 A054 BNH 84(,R10) =(00054) EF44
000050 47F0 A078 B 120(,R10) =(00078) GOTO EF44
0110 ADD 1.00 TO P
000054 0D9B BASR R9,R11 ADD 1724A
000056 0092 DC X'0092' 17278
000058 FA41 7004 819F AP P(5),#KST019F(2) 20A0
00005E 0D90 BASR R9,0 F12A
000060 4710 B15C BO NAT1301 1071C
000064 910D 7008 TM P+4,X'0D' 120B0
000068 4710 A070 BO 112(,R10) =(00070) 120F6
00006C 960F 7008 OI P+4,X'0F' 1210ª
0120 END-FOR
0130 *
000070 0D9B BASR R9,R11 GOTO 1724A
000072 00A4 DC X'00A4' 17278
000074 47F0 A02A B 42(,R10) =(0002A) EF44
0140 T:=*TIMD(0080)
000078 0D9B BASR R9,R11 SYFU 1724A
00007A 00AE DC X'00AE' 17278
00007C 4DE0 B0D8 BAS R14,SYSFUNC 5F1A
000080 0190 B881 DC X'0190B881' 5F28
000084 F246 7009 8190 PACK T(5),#KST0190(7) MOVE AD18
00008A 910F 700D TM T+4,X'0F' 12130
00008E 4710 A0A0 BO 160(,R10) =(000A0) 12176
000092 17EE XR R14,R14 1218E
000094 43E0 700D IC R14,T+4 12194
000098 43EE B488 IC R14,PSGNTR(R14) 121AA
00009C 42E0 700D STC R14,T+4 121B2
0000A0 F040 7009 0002 SRP T(5),2,0 ACA2
0000A6 17EE XR R14,R14 1218E
0000A8 43E0 700D IC R14,T+4 12194
0000AC 43EE B488 IC R14,PSGNTR(R14) 121AA
0000B0 42E0 700D STC R14,T+4 121B2
0150 T:=T / 10
0160 *
0000B4 0D9B BASR R9,R11 DIV 1724A
0000B6 00C0 DC X'00C0' 17278
0000B8 F864 D100 7009 ZAP OP1(7),T(5) AC60
0000BE FD61 D100 81A1 DP OP1(7),#KST01A1(2) 327A
0000C4 F844 7009 D100 ZAP T(5),OP1(5) AC60
0000CA 910D 700D TM T+4,X'0D' 120B0
0000CE 4710 A0D6 BO 214(,R10) =(000D6) 120F6
0000D2 960F 700D OI T+4,X'0F' 1210A
0170 DISPLAY 'ELAPSED TIME (S)' T
0000D6 4DE0 B040 BAS R14,RETH RETN F0AA
0000DA 00D2 DC X'00D2' F0C0
0180 END
0000DC 40D6 D7E3 F844 2000 DC X'40D6D7E3F8442000' =' OPT8à..' END 927E
0000E4 0000 0000 DC X'00000000' nf
0000E8 40D5 D6C3 F8F4 F140 DC X'40D5D6C3F8F4F140' =' NOC841 ' 92E4
The UNICC option controls the generation of optimized code for
IF, DECIDE FOR and DECIDE ON statements that
contain Unicode operands.
Valid values for UNICC are:
| Value | Explanation |
|---|---|
ON |
Generates optimized code and checks whether COLLATE=OFF is
set (see the CFICU profile parameter in the
Parameter Reference documentation).
If
|
FORCE |
Generates optimized code analogous to ON but
without COLLATE=OFF check.
The code optimized with
|
OFF |
Optimized code is not generated.
|
The Natural Optimizer Compiler generates optimized code for Natural statements with Unicode strings if the following requirements are met:
| Statement | Requirement |
|---|---|
| All statements | All operands used in the statement must be of the type Unicode. |
EXAMINE |
The ARCH option must be set to a value greater than or
equal to 6.
|
IF
|
|
MOVE
|
The ARCH option must be set to a value greater than or
equal to 5.
|
The global parameter ZD influences the behavior of the NOC
compiler. See the description of the ZD option as described under List of Options above.
The COMPOPT parameter PSIGNF (see also the system
command COMPOPT in the Natural System
Commands documentation) influences the behavior by forcing the signs of
positive packed decimal numbers to F if ON, and to C if OFF.
The parameter is applied if NOSGNTR=OFF is specified.
See the chart below for packed data (Format P) ":"
NOSGNTR=OFF |
and | PSIGNF=ON |
All signs are normalized to F (default). |
NOSGNTR=OFF |
and | PSIGNF=OFF |
All signs are normalized to C. |
NOSGNTR=ON |
All signs are left as they were generated by the last operation. | ||
For numeric data (Format N) the signs are always normalized to F, regardless of the