CONNX Data Integration Suite 14.8.0 | Installation Guide | Installation Steps | DB2 Host Configuration | CONNX and z/OS Databases | Configuring MPTN-Specific VTAM Information on the Host
 
Configuring MPTN-Specific VTAM Information on the Host
 
Creating an SNATCP Macro
Verifying IP Address and Host Name
Creating an SNATCP Macro
The following includes the definition for using SNA over TCP/IP:
STCPIP
VBUILD TYPE = TCP
DNSUFX = CONNX.DB2390.com,
TCP = 50,
PORT = 397,
STCPGI GROUP I STATUS = ACTIVE,
STCPL1 LINE STATUS = ACTIVE,
STCPP1 PU STATUS = ACTIVE,
NETID = CONNXDB2
DNSUFX is the TCP/IP domain name suffix for symbolic TCP/IP addresses. Full MPTN/TCP/IP addresses are of the form Luname.netid.suffix, where suffix can be a three-part name as defined above.
Note that port 397 is reserved for MPTN traffic and that NetID is the VTAM Net ID to which the target host belongs. CONNXDB2 is a sample Net ID, and CONNX.DB2390.COM is a sample DNS suffix.