Text | Cause | Action |
GetFirstRecord() Error 1021: Invalid key access method specified. | This is an internal CONNX logic error. | Contact a Software AG technical representative. |
GetFirstRecord() Error 1023: Invalid READ direction specified. | This is an internal CONNX logic error. | Contact a Software AG technical representative. |
GetFirstRecord() Error 1024: Invalid search operator specified. | This is an internal CONNX logic error. | Contact a Software AG technical representative. |
GetFirstRecord() Error 1027: ksearch() / fseek() failed. | File-positioning function ksearch (VSAM) or fseek() (QSAM or PDS) failed; the file I/O request is unsuccessful. | Follow procedure
Started Task VSAM/QSAM/PDS: Error Message Diagnostics. |
GetFirstRecord() Error 1029: kretrv() failed. | The file I/O function kretrv() failed to read the target VSAM file. | Follow procedure
Started Task VSAM/QSAM/PDS: Error Message Diagnostics. |
GetFirstRecord() Error 1031: seek to start-of-file failed. | The function kseek() (VSAM) or fseek() (QSAM / PDS) failed to set the file pointer to start-of file. | Follow procedure
Started Task VSAM/QSAM/PDS: Error Message Diagnostics. |
GetFirstRecord() Error 1032: The target file is not searchable or seekable. | The target VSAM, QSAM, or PDS file does not have the saerchable / seekable attribute. | Re-import the file into the CONNX CDD and re-try the SQL statement. If the error persists, follow procedure
Started Task VSAM/QSAM/PDS: Error Message Diagnostics. |
GetFirstRecord() Error 1033: The file pointer is NULL. | The target VSAM, QSAM, or PDS file pointer is NULL, due to an open() error, a dataset sharing conflict with another job, process, or task, or an internal logic error. | Re-try the SQL statement. If the error persists, follow procedure
Started Task VSAM/QSAM/PDS: Error Message Diagnostics. |
GetFirstRecord() Error 1037: The target file is not a VSAM data set. | Either there was a CONNX file import error, or the DDNAME or fully-qualified data set name in the CONNX execution JCL points to a non-VSAM data set. | Re-import the file into the CONNX CDD and re-try the SQL statement. If the error persists, follow procedure
Started Task VSAM/QSAM/PDS: Error Message Diagnostics. |
DoReadNextPrev() Error 1051: afread() error: 0 bytes returned and ferror() != 0. | The afread() file I/O function returned 0 bytes plus an error return code. | If the error is reproducible, follow procedure
Started Task VSAM/QSAM/PDS: Error Message Diagnostics. |
DoReadNextPrev() Error 1052: afread() error: bytes returned > 0 and ferror() != 0. | The afread() file I/O function returned a positive byte count and an error return code. | If the error is reproducible, follow procedure
Started Task VSAM/QSAM/PDS: Error Message Diagnostics. |
DoReadNextPrev() Error 1053: afread() error: return code < 0. | The afread() file I/O function returned an error code. | If the error is reproducible, follow procedure
Started Task VSAM/QSAM/PDS: Error Message Diagnostics. |
DoReadNextPrev() Error 1054: osget() error: return code != 0 (OK) or -1 (EOF). | An attempt to read the target file using the SAS/C BSAM record-oriented interface function returned an error code which was not 0 (OK) or -1 (EOF). | If the error is reproducible, follow procedure
Started Task VSAM/QSAM/PDS: Error Message Diagnostics. |
DoReadNextPrev() Error 1055: The target file is not a VSAM data set. | An attempt to read the target file failed because it is not a VSAM data set. Either the file attributes of the data set have been changed since it was last imported into the CONNX CDD, or this is an internal logic error. | Verify that the DDNAME or physical data set name stored in the CONNX CDD file points to a VSAM KSDS, ESDS, or RRDS dataset. If the target dataset is VSAM, contact a Software AG technical representative. |
DoReadNextPrev() Error 1056: The target file is not a QSAM dataset or a PDS member. | An attempt to read the target file failed because it is not a QSAM physical sequential data set or a fully-qualified PDS(member). Either the file attributes of the data set have been changed since it was last imported into the CONNX CDD, or this is an internal logic error. | Verify that the DDNAME or physical data set name stored in the CONNX CDD file points to a QSAM physical sequential data set or a fully-qualified PDS(member). If the target dataset organization (QSAM or PDS(member)) is correct, contact a Software AG technical representative. |