Deploying and Managing Apama Applications > Correlator Utilities Reference > Using the Apama component extended configuration file > Binding server components to particular addresses
Binding server components to particular addresses
To bind Apama server components to a particular address or set of addresses, specify a BindAddress line for each address. Specify this in the [Server] section of the extended configuration file. For example:
[Server]
BindAddress=127.0.0.1:15903
BindAddress=10.0.0.1
You can specify as many BindAddress lines as you want. Clients can connect to any of the listed addresses.
An IP address is required. If you do not specify a port, the Apama server components use the port that is specified when the correlator is started. This makes it possible to share extended configuration files if you want to restrict connections according to only addresses.
If you do not specify an extended configuration file when you start the correlator, or there are no BindAddress entries in the extended configuration file, the Apama components bind to the wildcard address (0.0.0.0).