This document describes how to shut down the Event Replicator Target Adapter in Windows and UNIX environments as how to stop it from the Administration tool.
Note:
The Event Replicator Target Adapter is automatically stopped and restarted every time an
Event Replicator Target Adapter definition is saved or deleted using the Administration tool. For this
reason, we recommend that you shut down the Event Replicator Target Adapter prior to making changes to
the definitions and restart the Event Replicator Target Adapter when all definition changes are
complete.
To shut down Event Replicator Target Adapter from the Administration tool:
Start up the Administration tool, as described in Starting the Administration Tool.
The Administration tool window appears.
Click on the
button () on the Administration tool window.Or:
On the menu, select .
The Event Replicator Target Adapter shuts down.
To shut down Event Replicator Target Adapter using the shutdownart batch file in Windows:
Navigate to the following directory: <installation-dir>/Event Replicator Target Adapter/Vv.r.s/bin, where <installation-dir> is the name of the directory in which the Event Replicator Target Adapter program files were installed and v.r.s represents the current version, release, and system modification level of the Event Replicator Target Adapter.
Run the shutdownart.bat file.
The Event Replicator Target Adapter shuts down.
To shut down Event Replicator Target Adapter in UNIX environments:
Navigate to the following directory: <installation-dir>\Event Replicator Target Adapter\Vvrs\bin, where <installation-dir>is the name of the directory in which the Event Replicator Target Adapter program files were installed and vrs represents the current version, release, and system modification level of the Event Replicator Target Adapter.
Enter shutdownart.sh
at the UNIX
prompt.
The Event Replicator Target Adapter shuts down.