ARST* - Adabas Review Interface Messages

Overview of Messages

ARST01 | ARST02 | ARST06 | ARST09 | ARST10 | ARST11

ARST01 dbid GETMAIN failure, size= requested-getmain-size
Explanation

A request for storage in the Adabas nucleus subtask ADARST failed.

Action

Either determine what is using so much storage in the Adabas nucleus and correct the problem; or increase the available storage.


ARST02 dbid LOAD FAILED FOR MODULE module
Explanation

The specified module cannot be loaded.

Action

Probably, the requested load module is missing.


ARST06 dbid Adabas Review subtask statistics
dbid Buffers in: count Buffers out: count
dbid UEX5 calls: count Timer calls: count posts: count
Explanation

This message displays ADARST shutdown statistics.

Action

None required. This message is for information only.


ARST09 dbid Subtask ADARST detached
Explanation

The subtask ADARST was detached for one of the following reasons:

  • An error occurred when accessing the Adabas Review hub

  • The Adabas Review hub returned Adabas response code 148 (ADARSP148 - not active)

As long as the subtask is not attached, this database will not send data to the Adabas Review hub.

Action

If the reason for the detachment is an unjustified Adabas response code 148 (ADARSP148), contact your Software AG technical support representative for assistance.


ARST10 dbid Unrecoverable abend in subtask ADARST
Explanation

The subtask ADARST abended either due to an unrecoverable abend or to the second call of the ESTAE (in this case see previous ARSTxx messages).

The subtask is deactivated and the database will not send data to the Adabas Review hub.

Action

It is not possible to reactive the subtask using the ADARUN REVIEW=hubid parameter. You must restart the database to reactivate Adabas Review.


ARST11 dbid Abend S0D6 occurred
nnnnn Possibly the REVIEW hubid = hhhhh ended abnormally.
Explanation

This error messages can only occur in an Adabas nucleus, if an Adabas Review hub is installed using the Trans-port feature. For some reason the PC number for the PC call is invalid.

The ARST07 message is issued and the ADARUN REVIEW parameter is set to NO.

Action

Determine the reason for the abend S0D6. It is likely that the Adabas Review hub has abended. If necessary, contact you Software AG support representative for further assistance.