ADASIP00 | ADASIP01 | ADASIP02 | ADASIP03 | ADASIP04 | ADASIP05 | ADASIP06 | ADASIP08 | ADASIP09 | ADASIP10 | ADASIP11 | ADASIP12 | ADASIP13 | ADASIP14 | ADASIP15 | ADASIP16 | ADASIP17 | ADASIP18 | ADASIP19 | ADASIP20 | ADASIP21 | ADASIP22 | ADASIP23 | ADASIP24 | ADASIP26 | ADASIP27 | ADASIP28 | ADASIP29 | ADASIP30 | ADASIP31 | ADASIP32 | ADASIP33 | ADASIP36 | ADASIP37 | ADASIP38 | ADASIP39 | ADASIP40 | ADASIP41 | ADASIP50 | ADASIP60 | ADASIP61 | ADASIP62 | ADASIP63 | ADASIP64 | ADASIP65 | ADASIP66 | ADASIP67 | ADASIP68 | ADASIP69 | ADASIP70 | ADASIP71 | ADASIP72 | ADASIP73 | ADASIP74 | ADASIP75 | ADASIP76 | ADASIP77 | ADASIP78 | ADASIP79 | ADASIP80 | ADASIP81 | ADASIP85 | ADASIP86 | ADASIP87 | ADASIP88
ADASIP00 | Adabas Vav.ar VSE SIP started
SIP is running under z/VSE Vvv.vr.vm ( yyyy-mm-dd. SM=sm-level , ZAP=zap-level) SIP IS LOADING ADABAS SVC LEVEL sv.sr.sm ADASIP IS LOADING ADABAS SVC AMODE=a-mode |
||||||||||||||||
Explanation |
The ADASIP program has started. The following substitutions appear in the message:
|
ADASIP01 | SUBSID macro error |
Explanation |
ADASIP received a nonzero return code from the operating system. |
Action: |
The z/VSE operating system release level is too low for installing Adabas. Refer to the Adabas Installation documentation for the minimum allowed z/VSE levels. |
ADASIP02 | Unsupported VSE release based upon SUBSID |
Explanation |
An ADASIP validation check indicates an unsupported operating system level. |
Action: |
The z/VSE operating system release level is too low for installing Adabas. Refer to the Adabas Installation documentation for the minimum allowed z/VSE levels. |
ADASIP03 | No SYSPARM value specified for SVC |
Explanation |
ADASIP could not find a SYSPARM input, and a zap has not be applied to the specified SVC. |
Action: |
Either provide the SVC with SYSPARM or apply a zap to the specified SVC with ADASIP. |
ADASIP04 | Default value used for the SVC |
Explanation |
No SYSPARM SVC has been used. ADASIP defaults to using the SVC that has a zap applied. |
ADASIP05 | Non-numeric data found in SYSPARM field |
Explanation |
Either SYSPARM or the default ADASIP SVC contains a nonnumeric value. |
Action: |
Correct the specified SYSPARM value, or set the default SVC value to 30. |
ADASIP06 | Invalid range specified for the SVC 31-256 |
Explanation |
ADASIP found an SVC outside the allowed range in SYSPARM or the ADASIP default SVC. |
Action: |
Set the SVC to an unused SVC value within the allowed range. SVC ranges and recommended values are described in the Adabas Installation documentation . |
ADASIP08 | ADASVCvv was not found in the SVA |
Explanation |
While performing a z/VSE load, ADASIP found that the specified level ADASVC was not in the SVA. |
Action: |
Issue the SET SDL for ADASVCvv. It may be necessary to relink the Adabas SVC with SVA using the PHASE statement if the Adabas SVC is not found in the Adabas library. |
ADASIP09 | No match on ID - incorrect ADASVC loaded |
Explanation |
ADASIP found an incorrect SVC version while attempting a load operation. |
Action: |
Relink ADASVCvv with the correct SVC module. |
ADASIP10 | Unknown keyword in PARM field |
Explanation |
ADASIP found an incorrect keyword in the PARM field. |
Action: |
Correct the keyword parameter and rerun the job. |
ADASIP11 | Non-numeric data specified for NRIDTES |
Explanation |
The ADASIP NRIDTES= keyword parameter specified non-numeric data. |
Action: |
Correct the NRIDTES= data, then resubmit ADASIP. |
ADASIP12 | No overriding NRIDTES specified |
Explanation |
The default NRIDTES was used. No error has occurred. |
ADASIP13 | SVC table entry was found to be invalid |
Explanation |
The SVC number provided by SYSPARM is either not valid, or does not represent either the old or new version of the z/VSE Adabas SVC. This error can occur if the UPSI statement's "C" parameter specified "0". |
Action: |
Respecify the UPSI statement, or specify another unused SVC value. Rerun ADASIP. |
ADASIP14 | GETVIS failure for IDT in SVA |
Explanation |
The GETVIS of the IDT passed a nonzero return code back to ADASIP, meaning the GETVIS size was insufficient. |
Action: |
Increase the SVA GETVIS size, re-IPL the operating system, and rerun ADASIP. |
ADASIP15 | Router unable to initialize IDT |
Explanation |
ADASIP received a nonzero return code from the 56 call to the SVC. |
Action: |
Contact your Software AG technical support representative. |
ADASIP16 | WARNING -- IDT table already exists |
Explanation |
ADASIP detected that an IDT table for this SVC already exists. |
Action: |
No action is required for this warning message. |
ADASIP17 | Incorrect SVC suffix after comma in SYSPARM |
Explanation |
An attempt was made to run this program more than once for the current IPL. A second IDT for the program is not required. |
Action: |
Correct the SYSPARM specification for the two-byte SVC suffix, and rerun the job. |
ADASIP18 | Non-numeric data specified for DMPDBID |
Explanation |
The ADASIP DMPDBID keyword parameter contains nonnumeric data. |
Action: |
Correct the DMPDBID specification, and rerun the job. |
ADASIP19 | DBID cannot be found in IDTE |
Explanation |
The ADASIP program could not find an entry for the DMPDBID database in the IDT area. |
Action: |
Either correct the DMPDBID specification or start the specified database, then run ADASIP to perform a "snap" dump of the command queue. |
ADASIP20 | The IDT and SVC have been dumped to SYSLST |
Explanation |
A request to ADASIP to dump the IDT and then SVC via UPSI 80. No error has occurred. |
ADASIP21 | No IDT table was found for specified SVC |
Explanation |
ADASIP found that the SVC has no address for the IDT. |
Action: |
Specify the correct SVC, or initialize with ADASIP first. |
ADASIP22 | The SVC has already been installed |
Explanation |
ADASIP found that the same program is being run again. |
Action: |
The SVC is not installed and no IDT table is needed. To reinstall the same SVC, you must first perform a SET SDL. |
ADASIP23 | The SVC table cannot be listed under DOS/MVT |
Explanation |
The option to display the SVC table is specified under z/VSE. |
ADASIP24 | The IDT has been pagefixed by user option |
Explanation |
UPSI (X'20') was selected to pagefix the IDT in the system GETVIS area. |
ADASIP26 | Could not load the ADAOPD table |
Explanation |
ADASIP was unable to load phase ADAOPD. |
Action: |
Ensure that ADAOPD is available for loading and rerun the job. |
ADASIP27 | ADASVCxx must be AMODE=31, RMODE=24 |
Explanation |
ADASIP detected that the Adabas SVC has invalid link-edit attributes. |
Action: |
Relink the Adabas SVC with the correct attributes and rerun the job. |
ADASIP28 | ADASIP is AMODE=31 |
Explanation |
ADASIP detected that it is AMODE=31. |
Action: |
Relink ADASIP AMODE=24. |
ADASIP29 | PRODID macro failure |
Explanation |
ADASIP received a nonzero response code from the PRODID DEFINE macro. |
Action: |
Investigate the cause of the error. Correct it and rerun the job. |
ADASIP30 | ADASVCvv svc installed (Date yyyymmdd) |
Explanation |
ADASIP has installed SVC number svc successfully. |
ADASIP31 | address=SVC address |
Explanation |
The SVC has been loaded at the indicated address. |
ADASIP32 | address=IDT address |
Explanation |
The ID table has been allocated at the indicated address. |
ADASIP33 | Invalid value specified for REPLACE parameter |
Explanation |
An invalid value was specified on the REPLACE parameter. |
Action: |
Specify YES, Y, NO or N for the REPLACE parameter and rerun the job. |
ADASIP36 | address=extended IIBS address |
Explanation |
The extended IIBs have been loaded at the indicated address. |
ADASIP37 | address=IDT Extension address |
Explanation |
The IDT extension has been allocated at the indicated address. |
Action: |
No action is required for this informational message. |
ADASIP38 | address=SVC Work Area address |
Explanation |
The SVC work area has been allocated at the indicated address. |
Action: |
No action is required for this informational message. |
ADASIP39 | Error -- Targets still active on SVCnnn |
Explanation |
ADASIP detected that there are still active targets on the SVC listed in the message (nnn) and is unable to continue processing. |
Action: |
No action is required for this informational message. |
ADASIP40 | VSE SVC svc is status AM=a-mode RM=r-mode AR=reg-mode SVCT=svc-tab-addr MODT=svc-mod-addr | ||||||||||||||
Explanation |
This message occurs when the option to list the SVC table is selected, and specifies the following values:
|
||||||||||||||
Action: |
None required. This message is for your information only. Do not use SVC50, even though it is indicated as "unused". |
ADASIP41 | VSE SVC table audit completed |
Explanation |
ADASIP has completed listing the z/VSE SVC table. |
ADASIP50 | The command queue has been dumped to SYSLST |
Explanation |
ADASIP has completed listing the command queue for the specified database. |
ADASIP60 | Only 1 CPU can be active during ADASIP |
Action |
Use "SYSDEF TD,STOP=ALL" to stop all but one CPU so that ADASIP can run. Then restart your CPUs again. |
ADASIP61 | Rerun ADASIP after using TDSERV to stop CPUs |
Explanation |
Occurs in conjunction with ADASIP60. |
ADASIP62 | GETVIS failed for ADASTUB module |
Explanation |
Not enough SVA storage to load ADASTUB. |
Action |
Consult with your system programmer. |
ADASIP63 | ADASTUB module loaded at address |
Explanation |
Information message indicating module load address. |
ADASIP64 | No match on ID - incorrect ADASTUB loaded |
Explanation |
ADASTUB phase is incorrect. |
Action |
Consult with your system programmer, or contact Software AG. |
ADASIP65 | ADASTUB SVC table not found |
Explanation |
ADASTUB phase is incorrect. |
Action |
Consult with your system programmer, or contact Software AG. |
ADASIP66 | ADASTUB SVC table is full |
Explanation |
You have more than 10 SVCs active on this z/VSE machine. |
Action |
Contact Software AG for information about increasing the table size. |
ADASIP67 | PAGEFIX for ADASIP failed |
Action |
Increase the SETPFIX value and rerun. |
ADASIP68 | PAGEFREE for ADASIP failed |
Action |
Consult with your system programmer. |
ADASIP69 | TURBO dispatcher stub active |
Explanation |
Adabas Turbo support is now active on this z/VSE machine. |
ADASIP70 | VSE supervisor hook install failed |
Explanation |
Either this version of the z/VSE 2 supervisor is not supported, or the vendor installation logic for the first-level interrupt handler is incorrect. |
Action |
Call Software AG; have message ADASIP72 available. |
ADASIP71 | Load of module ADASTUB failed |
Explanation |
The ADASTUB module was not found in the LIBDEF SEARCH chain. |
ADASIP72 | Code is : code |
Explanation |
Occurs after message ADASIP70. |
ADASIP73 | ADANCHOR incorrect or not found in SVA |
Explanation |
The ADANCHOR module was not found in the SVA; no SET SDL has been done. |
ADASIP74 | Info: Stub activated by previous ADASIP |
Explanation |
Adabas Turbo STUB has been installed by a previous ADASIP. |
ADASIP75 | ADANCHOR and ADASTUB not dumped - not active |
Explanation |
When attempting to dump Adabas control blocks with ADASIP, the modules were not dumped because Adabas Turbo support is not active. |
ADASIP76 | Adabas turbo stub not activated due to error |
Explanation |
An error occurred during the installation of the Adabas Turbo stub. |
ADASIP77 | This Adabas SVC will run in non-turbo mode |
Explanation |
An error occurred during the installation of the Adabas Turbo stub. This SVC will run in non-Turbo mode from now on. |
ADASIP78 | VSE turbo dispatcher nn |
Explanation |
Version of z/VSE Turbo Dispatcher. |
ADASIP79 | Should we stop the CPUs? (yes/no) |
Explanation |
This message appears following ADASIP60 if more than one CPU is active during ADASIP processing. |
Action |
Replying "no" terminates the job. Replying "yes" causes CPUs to be temporarily deactivated while ADASIP runs. ADASIP will reactivate any deactivated CPUs before terminating. |
ADASIP80 | SVCnnn Target ID id is active in partition pp |
Explanation |
ADASIP does not allow an SVC to be reinstalled if there are active targets using the SVC, unless parameter REPLACE=YES is specified. If ADASIP parameter REPLACE=YES was specified, ADASIP replaces the current SVC regardless of any active targets. An attempt to reinstall an SVC by rerunning ADASIP when there are active targets using the SVC results in warning messages ADASIP80 and ADASIP81 being issued. If the reply to ADASIP81 is "no", ADASIP terminates processing. If the reply to ADASIP is "yes", ADASIP will check again for active targets. If active targets are found, messages. ADASIP80 and ADASIP81 will appear again. To proceed with ADASIP processing, active targets must be terminated before replying "yes" to message ADASIP81. Note: |
Action |
No action is required for this warning message. |
ADASIP81 | Should we continue processing? (yes/no) |
Explanation |
An attempt was made to reinstall an SVC while there are active targets using the SVC. Unless the ADASIP parameter REPLACE=YES is specified, ADASIP does not allow an SVC to be reinstalled if there are active targets using the SVC. This prompt allows you to continue or stop processing. |
Action |
Enter "yes" to continue or "no" to terminate processing. |
ADASIP85 | SVA-24 storage allocated: nnnnnK SVA-31 storage allocated: nnnnnK |
Explanation |
ADASIP has allocated nnnnnK of SVA storage below (SVA-24) or above (SVA-31) the 16 MB line. |
Action |
No action is required for this informational message. |
ADASIP86 | Reuse previous ADASTUB loaded at address? (yes/no) SVA-31 storage allocated: nnnnnK |
Explanation |
ADASIP detected that ADASTUB has already been loaded. A SET SDL for ADANCHOR should only be issued once per IPL. However, if ADASIP is rerun, and a SET SDL for ADANCHOR is issued a second time in error, it should be possible to preserve the existing Adabas communications environment by answering "yes" to message ADASIP86. |
Action |
Reply "yes" to reuse the ADASTUB or "no" to load a new copy of ADASTUB. The recommended reply is "yes". Do not reply "no" to this message unless directed to do so by your Software AG technical support representative. |
ADASIP87 | SYSLST unavailable |
Explanation |
ADASIP is not able to print messages on SYSLST, as this is unavailable. Console messages only will be issued. ADASIP continues processing., |
Action |
No action is required for this informational message. |
ADASIP88 | Invalid parameter combination |
Explanation |
ADASIP detected an invalid combination of PARM parameters or UPSI bytes. |
Action |
Correct the parameters or UPSI bytes and rerun the job. |