Option "A" is used to add a preformatted data set to the Associator or Data Storage. Before using this option, the data set to be added must be formatted using the ADAFRM utility.
Option "A" should be used only if the new data set is located on a different physical device. The Associator and Data Storage can each have as many as five data sets.
09:34:21 ***** A D A B A S BASIC SERVICES ***** 2006-07-20 DBID 105 - Add Dataset - PDMA002 Enter Parameters to Add either a DATA OR ASSO dataset: ASSO Device ....... ____ ASSO Size ......... __________ DATA Device ....... ____ DATA Size ......... __________ Blocks/Cylinders .. B |
This function corresponds to the utility function ADADBS ADD.
The equivalent direct commands are
ADD ASSO
ADD DATA