Version 8.1.4
 —  Messages and Codes  —

ADARPP Error Messages

Overview of Messages

ERROR-121 | ERROR-122 | ERROR-123 | ERROR-124 | ERROR-125 | ERROR-126 | ERROR-127 | ERROR-128 | ERROR-129 | ERROR-130 | ERROR-131 | ERROR-132 | ERROR-133 | ERROR-134

ERROR-121 Parameter PRINT must be set to DUMP, FORMAT or BOTH
Explanation

An invalid value was specified for the ADARPP PRINT parameter. Valid values are listed in the message.

Action

Correct the value and try again.


ERROR-122 Date and time must be reasonable. Date must be entered in the form YYYYMMDD. Time must be entered in the form HHMMSSTH.
Explanation

An invalid value was specified for a date or time parameter in an ADARPP run. The date must be later that 1982 and the time value must be less than 24 hours.

Action

Correct the relevant date or time parameter and try again.


ERROR-123 Parameter STATE must be set to YES, or NO.
Explanation

An invalid value was specified for the ADARPP STATE parameter. Valid values are listed in the message.

Action

Correct the value and try again.


ERROR-124 Print level must be in the range 0 to n inclusive for parameter
Explanation

The print level specified for the ADARPP parameter identified in the message is invalid.

Action

Review the valid settings for the named print parameter, correct the value, and try again.


ERROR-125 Record number nnn: URBLTYPE: aa is not supported. Consult Software Support.
Explanation

The record contains an unknown record type value.

Action

Contact your Software AG technical support representative.


ERROR-126 FROMDATE and FROMTIME must be <= to TODATE and TOTIME
Explanation

The date and time specified by the ADARPP FROMDATE or FROMTIME parameters is later than the date and time specified by the TODATE and TOTIME parameters. This is invalid.

Action

Correct the appropriate date or time value and try again.


ERROR-127 Parameter TIMEZONE must be set to MACHINE, LOCAL, or an integer value in the range -23 to +23. When entering + or -, enclose the number in single quotes.
Explanation

An invalid value was specified for the ADARPP TIMEZONE parameter. Valid values are listed in the message.

Action

Correct the value and try again.


ERROR-128 Record number nnn: URBLPTYP nn is inconsistent with eye-catcher aaaa, Consult Software Support.
Explanation

The record contains a data type that is not consistent with the actual data.

Action

Contact your Software AG technical support representative.


ERROR-129 Record number nnn: URBLPTYP nn is not supported. Consult Software Support.
Explanation

The record contains an unknown data type value.

Action

Contact your Software AG technical support representative.


ERROR-130 Failure on writing to print file. Consult Software Support.
Explanation

An error occurred when a record was being written to the Report file.

Action

Contact your Software AG technical support representative.


ERROR-131 Open failed for file DDCLOG with returned code of nn.
Explanation

No DDCLOG file was specified in the ADARPP JCL.

Action

Correct the JCL and rerun the job.


ERROR-132 Invalid parameters supplied.
Explanation

At least one parameter value was invalid.

Action

Check all error messages to identify the invalid parameter values, make corrections to the values, and try again.


ERROR-133 nnnn CLOG records were read, and nnnn records were selected for printing.
Explanation

A summary of the CLOG records read and selected for printing is listed in the message. This is part of the summary report at the end of the print file.

Action

No action is necessary for this informational message.


ERROR-134 PAGESIZE must be 20 or greater
Explanation

An invalid value was specified for the ADARPP PAGESIZE parameter. Valid values must range from 20 or greater.

Action

Correct the value and try again.