ERROR-122 | ERROR-124 | ERROR-125 | ERROR-126 | ERROR-127 | ERROR-130 | ERROR-131
ERROR-122 | Incorrect FDT found in input datatset |
Explanation |
The structure of the FDT read from the input data set does not satisfy the rules. |
Action |
Check whether the input data set is valid. Supply a correct input data set and rerun the job. |
ERROR-124 | Invalid value for the parameter ADAMDE |
Explanation |
The name of the ADAM descriptor was not found in the FDT. |
Action |
Supply ADAMDE=ISN or ADAMDE=xx, where "xx" is any valid descriptor name. Then rerun the job. |
ERROR-125 | Invalid ADAMDE field: xx |
Explanation |
Conflicting field attributes or unknown descriptor name. An ADAM descriptor must
|
Action |
Supply the correct parameter value and rerun the job. |
ERROR-126 | Invalid value for the parameter BITPARM |
Explanation |
See the Adabas Utilities documentation for further information. |
Action |
Supply the correct parameter value and rerun the job. |
ERROR-127 | Data Storage size too small |
Explanation |
The amount of Data Storage to store the records is greater than the data size parameter. |
Action |
Supply the correct parameter value and rerun the job. |
ERROR-130 | Input dataset has spanned records. ADAM files may not be spanned. |
Explanation |
The input data set has spanned record support active. The spanned record option is not allowed for ADAM files. |
Action |
Check whether the input data set is valid. Supply a correct input data set and rerun the job. |
ERROR-131 | Input dataset is a LOB file. ADAMER is not allowed for LOB files. |
Explanation |
The input data set is a large object (LOB) file. LOB files may not be input to ADAMER. |
Action |
Check whether the input data set is valid. Supply a correct input data set and rerun the job. |