Message Class 1005 - RPC Server

If you are communicating with an EntireX RPC server, this class is returned if an error occurred in the RPC server.

If you are communicating with a Natural RPC Server and you receive errors in the range 10050001 - 10059999 on the client side, make a note of the last 4 digits of the error number and refer to the Natural error code documentation to determine the cause of the error instead here. For example, if you receive error number 10050082, Natural error 0082 has occurred on the server side.

Messages of this class have the format:

1005nnnn

where 1005 is the message class, and
nnnn is the message number in the range 0000 - 9999.

Overview of Messages

10050000 | 10050001 | 10050002 | 10050003 | 10050004 | 10050005 | 10050006 | 10050007 | 10050008 | 10050009 | 10050010 | 10050011 | 10050012 | 10050013 | 10050014 | 10050015 | 10050016 | 10050017 | 10050018 | 10050019 | 10050021 | 10050022 | 10050023 | 10050024 | 10050025 | 10050026 | 10050027 | 10050028 | 10050029 | 10050030 | 10050031 | 10050032 | 10050033 | 10050034 | 10050035 | 10050036 | 10050037 | 10050038 | 10050039 | 10050040 | 10050041 | 10050042 | 10050043 | 10050044 | 10050045 | 10050046 | 10050047 | 10050048 | 10050049 | 10050050 | 10050051 | 10050052 | 10050053 | 10050054 | 10050055 | 10050056 | 10050057 | 10050058 | 10050059 | 10050060 | 10050061 | 10050062 | 10050063 | 10050064 | 10050065 | 10050066 | 10050067 | 10050068 | 10050069 | 10050074 | 10050075 | 10050076 | 10050077 | 10050082 | 10050083 | 10050084 | 10050085 | 10050086 | 10050087 | 10050088 | 10050089 | 10050090 | 10050091 | 10050092 | 10050093 | 10050094 | 10050095 | 10050096 | 10050098 | 10050099 | 10050100 | 10050101 | 10050102 | 10050103 | 10050104 | 10050110 | 10050111 | 10050112 | 10050113 | 10050114 | 10050116 | 10050117 | 10050118 | 10050119 | 10050120 | 10050122 | 10050123 | 10050124 | 10050125 | 10050126 | 10050127 | 10050129 | 10050130 | 10050131 | 10050132 | 10050134 | 10050135 | 10050136 | 10050137 | 10050138 | 10050139 | 10050140 | 10050142 | 10056971 | 10056974 | 10056977 | 10056978

10050000 Reserved

10050001 Cannot open or read File=<file name>
Explanation

An invalid configuration file name or a wrong file type was used to start the RPC server.

Action

Restart the server with correct configuration file.


10050002 Cannot open or read File=<file name>
Explanation

Configuration problem.

Action

Contact Software AG support


10050003 Bad configuration: endworkers set to timeout
Explanation

RPC server was started with an incomplete configuration file: Parameter endworkers has been set to timeout.

Action

Restart server with desired definition.


10050004 Bad configuration: MinWorkers set to <number>
Explanation

RPC server was started with an inconsistent configuration file: Parameter minworkers was either less than 1 or greater than the available thread entries.

Action

Restart server with desired definition.


10050005 Bad configuration: MaxWorkers set to <number>
Explanation

RPC server was started with an inconsistent configuration file: Parameter maxworkers was either greater than the available thread entries or (if endworkers=never was not specified) was less than 2.

Action

Restart server with desired definition.


10050006 MaxWorkers must not be less than MinWorkers
Explanation

RPC server was started with an inconsistent configuration file: Parameter minworkers was greater than maxworkers.

Action

Restart server with desired definition.


10050007 ERXInit() failed
Explanation

Initialization of ERX runtime failed. This message is accompanied by an ERX runtime error message.

Action

Check ERX runtime error message for further action.


10050008 Create Instance failed
Explanation

A new thread could not be established. This message is accompanied by message 10050009.

Action

See message 10050009 for further action.


10050009 Search for free entry in Thread table failed
Explanation

The predefined thread table is full. This table normally is 256 entries long, under CICS there are 38 entries located in the ERX main control block. With ENDW=USER, each user thread requires an additional entry.

Action

Check reason of the overflow: if a thread abnormally terminates (abends), the thread entry might be marked as UNUSABLE. If there are too many abnormal terminations during the lifetime of the RPC server, the table might be shortened. In other cases, contact Software AG support.


10050010 Get Server status failed
Explanation

Internal function failed. This message follows a genuine error message.

Action

Check original ERX error message for further action.


10050011 Set Server status failed
Explanation

Internal function failed. This message follows a genuine error message.

Action

Check original ERX error message for further action.


10050012 Follow Worker creation failed
Explanation

Internal function failed. This message follows a genuine error message.

Action

Check original ERX error message for further action.


10050013 ERXRegister() failed
Explanation

Register call to ERX runtime failed. This message is accompanied by a genuine error message.

Action

Check original ERX error message for further action.


10050014 ERXLogon() failed
Explanation

Logon call to ERX runtime (logon to Broker) failed. This message is accompanied by a genuine error message.

Action

Check original ERX error message for further action.


10050015 ERXLogoff() failed
Explanation

Logoff call to ERX runtime (logoff from Broker) failed. This message is accompanied by a genuine error message.

Action

Check original ERX error message for further action.


10050016 ERXUnregister() failed
Explanation

Unregister call to ERX runtime failed. This message is accompanied by a genuine error message.

Action

Check original ERX error message for further action.


10050017 Server Statistics:
Explanation

Informational. This message is the header of the statistic messages 10050018 - 10050023 which will be printed when RPC server terminates.

Action

None.


10050018 Conversations successful ............ <number>
Explanation

Informational. Prints the number of conversational and non-conversational calls.

Action

None.


10050019 Workers successful .................. <number>
Explanation

Informational. Prints the number of worker threads with normal end.

Action

None.


10050021 Workers failed in executing ......... <number>
Explanation

Informational. Prints the number of worker threads with abnormal end.

Action

None.


10050022 Workers maximum parallel active ..... <number>
Explanation

Informational. Prints the maximum number of concurrently active worker threads.

Action

None.


10050023 Workers failed in starting .......... <number>
Explanation

Informational. Prints the number of failing worker threads.

Action

None.


10050024 ERXEndServing() failed
Explanation

EndServing call to ERX runtime ( Broker DEREGISTER) failed. This message is accompanied by a genuine error message.

Action

Check original error message for further action.


10050025 Check Worker creation failed
Explanation

Internal function failed. This message is accompanied by a genuine error message.

Action

Check original error message for further action.


10050026 Create Worker failed
Explanation

Internal function failed. This message is accompanied by a genuine error message.

Action

Check original error message for further action.


10050027 Set Worker status failed
Explanation

Internal function failed. This message is accompanied by a genuine error message.

Action

Check original error message for further action.


10050028 Check for Worker stop failed
Explanation

Internal function failed. This message is accompanied by a genuine error message.

Action

Check original error message for further action.


10050029 Check for new Worker to create failed
Explanation

Internal function failed. This message is accompanied by a genuine error message.

Action

Check original error message for further action.


10050030 ERXDynamicParmGeneration() failed
Explanation

Internal function to prepare the data conversation failed. This message is accompanied by a genuine error message.

Action

Check original error message for further action.


10050031 ERXUnmarshal() failed for <library> <program>
Explanation

Internal function for data conversation failed, <library>=requested Library, <program>=requested Program. This message is accompanied by a genuine error message.

Action

Verify that the data received from client is correct. It may be necessary to reproduce the error while tracing is on.


10050032 ERXMarshal() failed for <library> <program>
Explanation

Internal function for data conversation failed, <library>=requested Library, <program>=requested Program. This message is accompanied by a genuine error message.

Action

Verify that the data sent by a server subroutine is correct. It may be necessary to reproduce the error while tracing is on.


10050033 Could not resolve RPC call for <library> <program>
Explanation

A client request could not be answered successfully. The client is notified with the appropriate protocol error, depending on the genuine error. This message is accompanied by a genuine error message.

Action

Check original messages for possible errors.


10050034 Exception Type=<type> received!
Explanation

SignalHandler indicates critical error. Depending on the operating system, dump information will be provided. Message 10050060 provides information about the program that is involved in this abend.

Action

Check message 10050060 for more information.


10050035 ERXBeginServing() failed
Explanation

BeginServing call to ERX runtime (Broker REGISTER) failed. This message is accompanied by a genuine error message.

Action

Check original error message for further action.


10050036 SAG EntireX RPC server <Runtime platform>
Explanation

Informational. This message is the header of the information messages 10050037 - 10050042 and 10050051 - 10050052 which are printed when RPC server is started.

Action

None.


10050037 Minworkers (free for new conversation) <number>
Explanation

Informational. Prints minworkers startup parameters.

Action

None.


10050038 Maxworkers (max parallel active) ..... <number>
Explanation

Informational. Prints maxworkers startup parameters.

Action

None.


10050039 Endworkers (criteria when to stop) ... <number>
Explanation

Informational. Prints endworkers startup parameters.

Action

None.


10050040 Timeout (in seconds for Broker) ... <seconds>
Explanation

Informational. Prints timeout startup parameters.

Action

None.


10050041 API used (for Broker) .............. <api-version>
Explanation

Informational. Prints ETB_APIVERS startup parameters.

Action

None.


10050042 Codepage (for data conversion) ..... <CodePage>
Explanation

Informational. Prints CODEPAGE startup parameters.

Action

None.


10050043 Invalid Thread Status
Explanation

Internal check has detected an error in thread status logic. The reason might be system shortages. The thread might be flagged unusable.

Action

Check if the server can still continue working. If not, restart server. If problem persists, contact Software AG support.


10050044 ERXDynDispatch() failed
Explanation

Dispatcher call to ERX runtime (Broker RECEIVE) failed. This message is accompanied by a genuine error message.

Action

Check original error message for further action.


10050045 SERVER
Explanation

Informational. This token is used to identify the originator thread of a message.

Action

None.


10050046 Worker
Explanation

Informational. This token is used to identify the original thread of a message.

Action

None.


10050047 Transaction Control Callback failed
Explanation

Internal function failed. This message is accompanied by a genuine error message.

Action

Check original error message for further action.


10050048 Server Control Callback failed
Explanation

Internal callback function failed. This message is accompanied by a genuine error message.

Action

Check original error message for further action.


10050049 Client Identification Callback failed
Explanation

Internal callback function failed. This message is accompanied by a genuine error message.

Action

Check original error message for further action.


10050050 Init Globals failed
Explanation

Internal function failed. This message is accompanied by a genuine error message. CICS: This message will also be used to dynamically initialize a shared memory block within the ERX Main control block.

Action

Check original error message for further action. CICS: Recompile and/or reload ERX Main control block.


10050051 Broker Id (default) ... <BrokerID>
Explanation

Informational. Prints BROKERID startup parameters (entered in the command line or configuration parameter BrokerID.

Action

None.


10050052 Service Name (default) ...... <ClassName><ServerName><Service>
Explanation

Informational. Prints CLASS SERVER SERVICE startup parameters (entered in the command line or configuration parameter Class, ServerName and Server).

Action

None.


10050053 Load of Memory <MapName> failed
Explanation

CICS only: ERX Main control block could not be loaded.

Action

Check CICS resource definitions and if module exist in DFHRPL load library.


10050054 Invalid Memory Version=<version> found in <MapName>
Explanation

CICS only: Invalid version detected in ERX Main control block. Either the version is out of support or (most likely) the control is corrupt.

Action

Recompile ERX Main control block with updated ERXMAIN macro.


10050055 Read of Memory <MapName> failed
Explanation

The message indicates an error with ERX Main control block. This message is accompanied by a genuine error message.

Action

Check original messages for possible errors.


10050056 Usage : <SeverName> Broker@Server/Class/Service [-Option]
or :
<SeverName> Broker Class Server Service [-Option]
or :
<SeverName> CFG=ConfigFile.cfg [-Option]
Explanation

Usage error. The correct syntax will be displayed. The server will terminate.

Action

Start server again with correct syntax.


10050057 or : <ServerName> MEM=memory
Explanation

Operating system-dependent USAGE message, part of message 10050056.

Action

Start server again with correct syntax.


10050058 Option : -s[ilent] suppresses input from STDIN Default: <ServerName> ETB001 RPC SRV1 CALLNAT
Explanation

Operating system-dependent USAGE message, part of message 10050056.

Action

Start server again with correct syntax.


10050059 Press Return key to continue.
Explanation

Part of message 10050056.

Action

Confirm usage messages and start server again with correct syntax.


10050060 Program program-name abended with exception= exception-code
Explanation

(Customer) server subroutine <program-name> has abended. Depending on the operating system, dump information will be provided. The server will continue running. The thread in which the abend occurred will be terminated or (if not possible) will be marked as UNUSABLE.

Action

Correct the malfunctioning subroutine.


10050061 Not yet implemented
Explanation

Informational message.

Action

None.


10050062 ERXTerminateServer() failed
Explanation

The complex function ERXTerminateServer will communicate with the Broker to stop all existing replicas for this server. This message is accompanied by a genuine error message.

Action

Check original error message for further action.


10050063 Conversations aborted ............... number
Explanation

Informational. Prints the number of "unsuccessful" calls:

  • all calls that return with error because of server subroutine problem and/or data conversations,

  • Broker (timeout) terminated the call

  • client terminates during conversation

  • in conversational mode: the conversation did not finish with DISCONNECT-COMMIT.

Action

None.


10050064 Thread stopped because of major problems
Explanation

Internal error in server. This message is accompanied by a genuine error message.

Action

Check original error message for further action.


10050065 ERXFreeVData() failed
Explanation

Service function failed. This message is accompanied by a genuine error message.

Action

Check original error message for further action.


10050066 The max. thread entries available ....... number
Explanation

Informational. This message is printed to a trace file. The maximum number of thread entries is 256.
Exception: under CICS it is automatically calculated from free memory in the ERX Main control block.

Action

None.


10050067 Server is starting.................
Explanation

Informational. This message is accompanied by a timestamp. The message will be generated after the Broker availability has been successfully tested. See also message no. 10050069.

Action

none


10050068 Server is stopping.................
Explanation

Informational. This message is accompanied by a timestamp.

Action

none.


10050069 Broker not available, has tried to connect x times
Explanation

The EntireX RPC server detected that the Broker is not available (either during startup or at runtime). Depending on the restartcycles option, the server will try to logon again after a one-minute timeout. If the Broker becomes available during these restart cycles, the server will continue with message 10050067. Otherwise, it will terminate.

Action

Restart Broker, if desirable.


10050074 Broker ID (in use) <BrokerID>
Explanation

Informational. Prints the Broker ID with which a session is requested. This Broker ID can be different from the default Broker ID.

Action

None


10050075 Service (in use) <ClassName>, <ServerName>, <Service>
Explanation

Informational. Prints the class name, server name and service with which a connection is established. The values can be different from the default or the logical service

Action

None


10050076 ERX runtime version and RPC server not compatible
Explanation

Your EntireX Installation is destroyed.

Action

Reinstall EntireX.


10050077 Response number from RPC server
Explanation

The EntireX RPC server returned an error.

Action

See under error number for further explanation and action to take.


10050082 Callee not found
Explanation

The EntireX/Natural RPC Server did not find the server program.

Action

Depending on the type of your RPC server, one of the following situations may apply:

  1. If the server is an EntireX RPC server on Windows/UNIX:

    • The server stub with the name D<library>.dll on Windows or D<library>.so|sl on UNIX must be accessible to the EntireX RPC server. The program called must be available within that library as an export named D<program>.

    • The same applies to the server program. A server with the name <library>.dll on Windows or <library>.so|sl on UNIX must be accessible to the EntireX RPC server. The program called must be available within that library as an export named <program>.

    Check read/execution access, library names and exports.

  2. If the server is an EntireX RPC server on CICS:

    • A program named <program> must exist in the DFHRPL steplib concatenation.

    • The program must be CSD-defined and (depending on CICS version) must be installed.

  3. If the server is a Natural RPC Server:

    • If Natural Logon is switched on for the request or conversation, the program must be found within the target library (or its steplib concatenation).

    • If Natural Logon is switched off for the request or conversation, the program must be found in the initial library (or its steplib concatenation) of the Natural RPC Server.

    See also the appropriate Natural documentation.

  4. If the server is an EntireX XML/SOAP RPC Server:

    • The server classes must be accessible from the EntireX XML/SOAP RPC Server.

    • Make sure that the path of the server classes is in the classpath.


10050083 SMH is listening on port <port>
Explanation

Informational. Message will be displayed if SMH service was successfully established. The local listener port will be exposed.

Action

None.


10050084 Shared library EXXRPCSTP not found or in error
Explanation

Some platforms require the shared library EXXRPCTCP to establish SMH services.

Action

Check your installation: On Windows, the library exxrpctcp.dll should be contained in <drive>:\SoftwareAG\EntireX\bin; on UNIX, the library libexxrpctcp.so should be contained in folder /opt/softwareag/EntireX/lib.


10050085 Major problems with TCP
Explanation

The EntireX RPC server could not use TCP to support SMH services. This message is issued if TCP requests fail completely.

Action

Contact your system administrator.


10050086 Invalid job control - WORKER-PARMS is empty
Explanation

The SDF variable WORKER-PARMS in S-procedure START-RPC-SERVER is not set up correctly. This message will be sent by RPC servers under BS2000/OSD only.

Action

Correct the job control and rerun the job.


10050087 Shared memory could not be established
Explanation

An error occurred while establishing the main or a worker task. This message will be sent by RPC servers under BS2000/OSD only.

Action

Contact Software AG support.


10050088 Abnormal termination during program execution
Explanation

The server program called by the EntireX/Natural RPC Server caused an abnormal end.

Action

Check the program and correct the error.


10050089 ERXSetSecurity() failed
Explanation

RPC server was started with option KERNELSECURITY, but failed.

This message is accompanied by a genuine error message.

Action

Correct installation error and restart.


10050090 Broker Kernel-Security.............. <level>
Explanation

Informational.

RPC server runs with broker KERNELSECURITY=<level>.

Action

None.


10050091 Authentication failed: user=<userid>, reason=<reason>
Explanation

The host security refused an authentication request.

Action

Inspect reason code. Retry if password mistyped, otherwise contact your security administrator.


10050092 Security could not be initialized, reason=<reason>
Explanation

Internal PC routines could not be installed.

Action

Inspect reason code and contact your system administrator.


10050093 Reserved
Explanation

 

Action

 


10050094 Cannot reset authentication, reason=<reason>
Explanation

The host security refused to reset a previously performed authentication request.

Action

Inspect reason code and contact your security administrator.


10050095 ERX Runtime not found
Explanation

EntireX RPC server requires the ERX shared library to be available. On Windows this is usually located in directory <drive>:\SoftwareAG\EntireX\bin.

Action

Check EntireX installation. Verify that the erx.dll is in standard installation path.


10050096 PL/I stack level exceeded
Explanation

RPC server received request for target PL/I application but application interface has higher indent level than PL/I supports (32).

Action

Correct RPC client application.


10050098 RPC server does not support RPC protocol version <rpc-version> found in server mapping
Explanation

The server mapping file accessed with IDL library and IDL program for the RPC request contained an RPC protocol version not supported by the RPC server. See Supported RPC Protocols. A server mapping file is an EntireX Workbench file with extension .svm or .cvm. See Server Mapping Files for COBOL.

Action

Contact Software AG support for RPC server upgrade.


10050099 Server mapping format is invalid
Explanation

The server mapping file accessed with IDL library and IDL program for the RPC request contained an invalid format. A server mapping file is an EntireX Workbench file with extension .svm or .cvm. See Server Mapping Files for COBOL.

Action

Check that you have the latest updates for the EntireX Workbench installed. Try to produce the server mapping again, see COBOL Wrapper or IDL Extractor for COBOL and retry.

  • If you are using server-side mapping files (.svm), deploy the correct server mapping to the RPC server. See Deploying Server-side Mapping Files to the RPC Server in the RPC server documentation for z/OS (CICS, Batch, IMS) | Micro Focus | CICS ECI | IMS Connect | BS2000/OSD | z/VSE (CICS | Batch).

    Note:
    For IMS Connect and CICS ECI connections with the webMethods EntireX Adapter, server-side mapping files are not deployed. They are wrapped into the Integration Server connection - the same as client-side mapping files. You need to update your Adapter connection. See Step 3: Select the Connection Type in the Integration Server Wrapper documentation. For RPC connections, deployment to the target RPC server is mandatory.

  • If you are using client-side mapping files (.cvm), you need to rebuild all RPC clients communicating with this RPC server program. Select the appropriate wrapper (see EntireX Wrappers) and re-generate the client interface objects. For RPC connections with the webMethods EntireX Adapter, you need to update your Adapter connection. See Step 3: Select the Connection Type in the Integration Server Wrapper documentation.

If this fails, contact Software AG support.


10050100 Reserved

10050101 Server mapping file in use........... Yes
Explanation

If the RPC server uses a server-side mapping container, this message will be printed, otherwise no message. See Server-side Mapping Files in the RPC Server in the RPC server documentation for z/OS (CICS, Batch, IMS) | BS2000/OSD | z/VSE (CICS, Batch).

Action

None.


10050102 EXTRACTOR service name reserved for internal use
Explanation

The RPC server did not come up. In the RPC server configuration, EXTRACTOR is specified as the broker service name, but EXTRACTOR is used for internal purposes of the RPC server and is a Software AG reserved service name.

Action

Do not specify EXTRACTOR as the broker service name in the RPC server configuration, and restart the RPC server.


10050103 DEPLOYMENT service name reserved for internal use
Explanation

The RPC server did not come up. In the RPC server configuration DEPLOYMENT is specified as the broker service name, but DEPLOYMENT is used for internal purposes of the RPC server and is a Software AG reserved service name.

Action

Do not specify DEPLOYMENT as the broker service name in the RPC server configuration, and restart the RPC server.


10050104 Deployment service defined but could not open SVM file
Explanation

The RPC server did not come up. In the RPC server configuration, the deployment service is specified (see Deployment Service for z/OS (CICS, Batch, IMS) | BS2000/OSD | z/VSE (CICS, Batch)), but the server-side mapping container could not be opened.

Action

Check your installation. Possible reasons:

  • The server-side mapping container is missing. For configuration see Enabling the Deployment Service for z/OS (CICS, Batch, IMS) | BS2000/OSD | z/VSE (CICS, Batch).

  • The server-side mapping container has mismatched DCB parameter.

  • ....


10050110 Call for CICS DFHCOMMAREA exceeds 32K limit
Explanation

The CICS RPC Server tried to call an RPC server with an interface of type CICS with DFHCOMMAREA Calling Convention (COBOL Wrapper | Extractor), but the length of the data exceeded the CICS DFHCOMMAREA maximum of 32 KB.

Action

Check the interface type of the target RPC server program called:

  • If it is not a DFHCOMMAREA interface but a Large Buffer or Channel Container interface, the server mapping file may be missing or is wrong. A server mapping file is an EntireX Workbench file with extension .svm or .cvm. See Server Mapping Files for COBOL.

    • If you are using server-side mapping files (.svm), deploy the correct server mapping to the RPC server. See Deploying Server-side Mapping Files to the RPC Server in the RPC server documentation for z/OS (CICS, Batch, IMS) | Micro Focus | CICS ECI | IMS Connect | BS2000/OSD | z/VSE (CICS | Batch).

      Note:
      For IMS Connect and CICS ECI connections with the webMethods EntireX Adapter, server-side mapping files are not deployed. They are wrapped into the Integration Server connection - the same as client-side mapping files. You need to update your Adapter connection. See Step 3: Select the Connection Type in the Integration Server Wrapper documentation. For RPC connections, deployment to the target RPC server is mandatory.

    • If you are using client-side mapping files (.cvm), you need to rebuild all RPC clients communicating with this RPC server program. Select the appropriate wrapper (see EntireX Wrappers) and re-generate the client interface objects. For RPC connections with the webMethods EntireX Adapter, you need to update your Adapter connection. See Step 3: Select the Connection Type in the Integration Server Wrapper documentation.

  • If it is a DFHCOMMAREA interface, it is not possible to call such an RPC server program. Check if you can migrate the RPC server program to a Large Buffer or Channel Container interface. See Supported COBOL Interface Types under Introduction to the IDL Extractor for COBOL or COBOL Server Interface Types under Introduction to the COBOL Wrapper.


10050111 Cannot load interface library EXX2MF
Explanation

The EntireX server was started as Micro Focus server, but the interface library EXX2MF was not found or could not properly be initialized.

Action
  • Check if the library EXX2MF can be found in the standard EntireX installation directory and if it is valid.

  • Check for the Micro Focus installation if the library directory is located in the OS-library path.

    Note:
    Software AG might not support Micro Focus on your platform.


10050112 EXX2MF initialization error
Explanation

The EntireX interface library EXX2MF could not properly perform (thread) initialization.

Action

Check the Micro Focus installation.


10050113 Invalid usage of SAG service
Explanation

EntireX services EXTRACTOR or DEPLOYMENT were used other than by broker services EXTRACTOR or DEPLOYMENT.

Action
  • For the EntireX RPC client: use broker service EXTRACTOR and broker service DEPLOYMENT respectively.

  • For the EntireX RPC server: configure the RPC server with EXTRACTOR=YES and DEPOLOYMENT=YES.

  • Allow services EXTRACTOR and DEPLOYMENT in the Broker attribute file.


10050114 No matching user ID
Explanation

The EntireX RPC server runs with optionIMPERSONATION=AUTO,SAME_USER. This requires the client to send both, the EntireX user ID as well as the RPC user ID and the IDs must be equal.

Action

Correct your EntireX client.


10050116 Deployment service not supported in that configuration
Explanation

Deployment service is feasible only when using the programming language COBOL for the server programs (see also configuration parameter MARSHALLING in the respective RPC documentation section).

Action

Check the RPC server configuration options for consistency.


10050117 Server mapping file (SVM) parameter required
Explanation

By default, COBOL support under UNIX or Windows requires a server-side mapping container, but no container was specified.

Action

Correct the RPC server configuration and provide a server-side mapping container; see Server-side Mapping Files in the RPC Server.


10050118 No SVM file/record found but required
Explanation

The RPC server runs with COBOL support but no server mapping file was found for this particular RPC request, where one is required. A server mapping file is an EntireX Workbench file with extension .svm or .cvm. See Server Mapping Files for COBOL.

Action
  • If you are using server-side mapping files (.svm), deploy the correct server mapping to the RPC server. See Deploying Server-side Mapping Files to the RPC Server in the RPC server documentation for z/OS (CICS, Batch, IMS) | Micro Focus | CICS ECI | IMS Connect | BS2000/OSD | z/VSE (CICS | Batch).

    Note:
    For IMS Connect and CICS ECI connections with the webMethods EntireX Adapter, server-side mapping files are not deployed. They are wrapped into the Integration Server connection - the same as client-side mapping files. You need to update your Adapter connection. See Step 3: Select the Connection Type in the Integration Server Wrapper documentation. For RPC connections, deployment to the target RPC server is mandatory.

  • If you are using client-side mapping files (.cvm), you need to rebuild all RPC clients communicating with this RPC server program. Select the appropriate wrapper (see EntireX Wrappers) and re-generate the client interface objects. For RPC connections with the webMethods EntireX Adapter, you need to update your Adapter connection. See Step 3: Select the Connection Type in the Integration Server Wrapper documentation.


10050119 Wrong SVM record type found
Explanation

The server mapping file accessed with IDL library and IDL program is inconsistent and does not match the RPC request. A server mapping file is an EntireX Workbench file with extension .svm or .cvm. See Server Mapping Files for COBOL.

Action

Check you have the latest updates for the EntireX Workbench installed. Try to produce the server mapping again and retry. See COBOL Wrapper or IDL Extractor for COBOL.

  • If you are using server-side mapping files (.svm), deploy the correct server mapping to the RPC server. See Deploying Server-side Mapping Files to the RPC Server in the RPC server documentation for z/OS (CICS, Batch, IMS) | Micro Focus | CICS ECI | IMS Connect | BS2000/OSD | z/VSE (CICS | Batch).

    Note:
    For IMS Connect and CICS ECI connections with the webMethods EntireX Adapter, server-side mapping files are not deployed. They are wrapped into the Integration Server connection - the same as client-side mapping files. You need to update your Adapter connection. See Step 3: Select the Connection Type in the Integration Server Wrapper documentation. For RPC connections, deployment to the target RPC server is mandatory.

  • If you are using client-side mapping files (.cvm), you need to rebuild all RPC clients communicating with this RPC server program. Select the appropriate wrapper (see EntireX Wrappers) and re-generate the client interface objects. For RPC connections with the webMethods EntireX Adapter, you need to update your Adapter connection. See Step 3: Select the Connection Type in the Integration Server Wrapper documentation.

If this fails, contact Software AG support.


10050120 WARNING! API-area was exceeded! Lib=<Library> Pgm=<program>
Explanation

EntireX server has found an application that exceeded the calculated API size. The impact depends on how much the limit is exceeded by.

Action

Check that the program interface definition (IDL file) matches the server's interface.


10050122 EntireX RPC server error 122 occurred
Explanation

An error occurred within the RPC Server runtime while deallocating storage during worker task shutdown.

Action

None.


10050123 Invalid transaction ID
Explanation

The (CICS) RPC server was started with transaction ID different to the transaction-id that was specified in ERXMAIN control block.

Action

The transaction IDs must be unique.


10050124 Server already active
Explanation

An attempt was made to start (CICS) RPC server a second time.

Action

This message was issued by the RPC server (see also message 10170004). Only one server instance can be started using the same shared memory block (ERXMAIN control block).


10050125 No free server resources available
Explanation

An attempt was made to start an RPC worker or user task, but the allocated thread table has no more free entries.

Action

Either reduce the MAXW parameter or increase the SIZE parameter. Check also the server log file for errors, because this situation may also be caused by aborting threads.


10050126 RPC Server is initialized
Explanation

Message of RPC server running under z/OS. Informational. Supports process automation.

Action

None.


10050127 RPC in closure
Explanation

Message of RPC server running under z/OS. Informational. Supports process automation.

Action

None.


10050129 Invalid parameter/program search order
Explanation

Internal error.

Action

Contact Software AG support


10050130 Service not supported. (<service>)
Explanation

The server was configured to use a feature that is not supported under this operating system.

Action

Change server configuration.


10050131 Setting CICS sync point failed (<resp>, <resp2>)
Explanation

RPC server under CICS tried to perform EXEC CICS SYNCPOINT (due to end of conversation) but failed.

Action

Check CICS response codes for this error.


10050132 Server option <option> deprecated
Explanation

At startup, the server found an option that is deprecated.

Action

The message is informational. Normally, the option will still be supported for compatibility reasons, but support may be withdrawn in a future release. See Release Notes for recommended action.


10050134 Reserved for internal use.

10050135 Reserved for internal use.

10050136 Reserved for internal use.

10050137 Reserved for internal use.

10050138 Reserved for internal use.

10050139 Reserved for internal use.

10050140 Reserved for internal use.

10050142 RPC Server initialization timeout at worker creation
Explanation

A final step of the server initialization is to launch the configured minimum number of worker tasks. If this does not succeed within 10 seconds, the server aborts the initialization.

Action

Verify server output for additional messages indicating problems with the worker initialization. Verify server trace output for additional error messages.


10056971 EntireX RPC server error 6971 occurred
Explanation

The cause of the error and corrective action depends on the type of your RPC server.

Action
  • If the server is an EntireX RPC server, contact Software AG support because of internal problems within the server.

  • If the server is a Natural RPC Server, see the appropriate Natural documentation for error 6971.


10056974 EntireX RPC server error 6974 occurred
Explanation

The cause of the error and corrective action depends on the type of your RPC server.

Action
  • If the server is an EntireX RPC server, increase your memory resources and retry the program because a memory request could not be fulfilled by the operating system.

  • If the server is a Natural RPC Server, see the appropriate Natural documentation for error 6974.


10056977 EntireX RPC server error 6977 occurred
Explanation

The EntireX/Natural RPC request could not be executed.

Action

Examine the log of the EntireX/Natural RPC Server for the cause of the malfunction.


10056978 EntireX RPC server error 6978 occurred
Explanation

The cause of the error and corrective action depends on the type of your RPC server.

Action
  • If the server is an EntireX RPC server, the reason could be an invalid compression value.

  • If the server is a Natural RPC Server, refer to the appropriate Natural documentation for error 6978.