This section describes messages that can occur with connections from the webMethods EntireX Adapter to IMS Connect. The messages have the format:
2011nnnn
where | 2011 | is the message class, and |
nnnn | is the message number in the range 0000 - 9999 |
20110001 | 20110009 | 20110010 | 20110011 | 20110012 | 20110013 | 20110014 | 20110015 | 20110022 | 20110023 | 20110301 | 20110302 | 20110303 | 20110304
20110001 | Process request and reply: illegal action <number indicating action> |
Explanation |
During request/reply processing the next action is illegal in the current state. |
Action |
Contact Software AG support. |
20110009 | <Exception with detailed message > |
Explanation |
An exception occurred while formatting the message. In most cases, the reason is an inconsistency in metadata. |
Action |
See detailed message or contact Software AG support. |
20110010 | Compression=off not possible |
Explanation |
An RPC with compression "0" or "off" is not supported. |
Action |
Change compression to 1 or 2. |
20110011 | Type of marshalling not allowed. or Unsupported call type <number of call type> |
Explanation |
There are two reasons for this error code:
|
Action |
Check configuration and client. |
20110012 | <Exception with detailed message> |
Explanation |
This exception occurs in message processing. |
Action |
See detailed message and contact Software AG support. |
20110013 | Preparing message failed, see log for details or Message received from server does not fit buffer |
Explanation |
There are two reasons for this error code. First, marshalling of message failed before sending to IMS Connect. Second, the received message has not the expected layout and the values cannot be unmarshalled from it. Marshalling of message failed before sending to IMS Connect. |
Action |
Check metadata (IDL, SVM, adapter connections) for consistency or contact Software AG support. |
20110014 | Transformation error on reply: <Exception with detailed message> |
Explanation |
The metadata is inconsistent or this data type is not supported. |
Action |
See detailed message or contact Software AG support. |
20110015 | Transformation error on request: <Exception with detailed message> |
Explanation |
This data type is not supported. |
Action |
See detailed message or contact Software AG support. |
20110022 | Unsupported command <command>. or Exception: <Exception with detailed message> |
Explanation |
There are two reasons for this error code.
|
Action |
See detailed message and log files or contact Software AG support. |
20110023 | Preparing message failed, see log for details |
Explanation |
Marshalling of message failed before sending to IMS Connect. |
Action |
Check metadata (IDL, SVM, adapter connections) for consistency or contact Software AG support.
Details can be found in |
20110301 | Receive only not supported |
Explanation |
This type of call is not supported. |
Action |
Modify your client. |
20110302 | Send only not supported |
Explanation |
This type of call is not supported. |
Action |
Modify your client. |
20110303 | <detailed error message from IMS Connect> |
Explanation |
IMS Connect reported an error, or the configuration is wrong. If IMS Connect returns code 16 and reason code 64, one cause is that the IMS exit is not installed or is not running. The default exit name is HWSSMPL0 (old) or HWSSMPL1 (new). Other configurations may also result in this return code and reason code. If the IMS Connect connection in the EntireX Adapter uses a port which is
not related to IMS but to some other application, a call may result in the
following message: If the IMS Connect RPC server uses a port which is not related to IMS but
to some other application, a call may result in the following message:
|
Action |
Use the error code from IMS Connect to correct this or correct the configuration. |
20110304 | Conversations not supported |
Explanation |
IMS Connect does not support conversational RPC calls. |
Action |
Use non-conversational calls. |