Dynamic Apps Platform : webMethods BPM Process Development Help : EDA Event Types : Adding a Custom EDA Event Type to a Message Step : Publishing an EDA Event from a Message Step
Publishing an EDA Event from a Message Step
This procedure applies to BPMN throwing message intermediate events and message end events.
To configure a message step to publish an EDA event
1. Select the message step you want to work with on the process canvas.
2. On the Implementation page in the Properties view, set the Send Protocol to EDA (For Event Triggered Processes).
3. Click the Browse button next to the Send Document field.
4. In the Choose Document dialog box, click the Search EDA Event Type Store tab, select the event type you want to use, and then click OK. You can also click the Browse Integration Server tab and select an IS document type that represents an EDA event type.
5. Verify the Connection Alias in use and specify a Destination Name.
6. Save the process.
Copyright © 2017 Software AG, Darmstadt, Germany.