To edit advanced controls, complete the following steps.
To edit advanced controls
1. Open Integration Server Administrator if it is not already open.
2. In the Security menu of the Navigation panel, click Ports.
You will see a Port List table in the main area of the screen.
3. In the Advanced column of this table, click Edit.
Integration Server displays a screen requesting information about Listener and Private Thread Pool Controls. Note that the Diagnostic HTTP Listener State and Private Threadpool areas of the screen are already populated with predefined values.
4. Enter the following information:
For this parameter...
Specify...
Listener controls
The type of controls you want to set, to manage the rate at which the listener accepts connections and other controls when the private thread pool is enabled.
Suspend. Stops the listener from accepting any more connections and subsequently dispatching any more requests.
Increase By. Increases the time that the listener will wait before accepting new client connections.
Decrease By. Decreases the time that the listener will wait before accepting new client connections.
Set To (Delay ms). Sets the delay time interval in milliseconds.
Private Thread Pool Controls
The type of thread pool control you want, in order to avoid the need for your port to compete with other server functions when Integration Server is handling multiple connections.
Increase By. Increases the number of threads in the private thread pool.
Decrease By. Decreases the number of threads in the private thread pool.
Set To (Threads). Sets the number of threads in the private thread pool.
5. Click Apply to accept your changes. Else, click Cancel.