Enabling Trace Logging for a Specific JMS Trigger
You can configure Integration Server to generate additional debug and trace logging for a specific JMS triggers.
Note: For the increased logging to appear in the server log, you must set the logging level for server facility 0134 JMS Subsystem to Trace.
To enable debug trace logging for a specific JMS trigger
1. Open Integration Server Administrator if it is not already open.
2. In the Settings menu of the Navigation panel, click Extended.
3. Click Edit Extended Settings.
4. Under Extended Settings, type the following:
watt.server.jms.debugTrace.triggerName=true
Where triggerName is the fully qualified name of the trigger in the format folder.subfolder:triggerName.
5. Click Save Changes.
6. Disable and then enable the trigger.