Global Property | Description | ||
UDDIOperatorName | Sets the operator attribute in UDDI V2 replies. The default value is CentraSite. | ||
UDDIDefaultLanguage | Sets the default language. All valid language identifiers are allowed. The default value is en-US. | ||
UDDIValueValidation | Activates or deactivates internal value validation. Valid values: true or false (default). For more information, see Checked Value Set Validation. | ||
UDDIKeyGeneratorChecks | Activates or deactivates the enforcement of keyGenerator tModels for publisher assigned keys. Valid values: true (default) or false. | ||
UDDIDiscoveryURLGeneration | Activates or deactivates the generation of discoveryURL. Valid values: true or false (default). | ||
UDDIEncoding | Specifies the XML encoding of the UDDI responses. Valid values: utf-8 (default) or utf-16. | ||
UDDISubscriptionDuration | The duration of a registry subscription. You can specify a default subscription expiration period for each UDDI web application separately. The subscription duration is specified using an xs:duration instance. It specifies a duration in terms of years, months, days, hours, minutes, and seconds. The default value is 1 month (xs:duration(P1M)). How a string holding an xs:duration instance is generated is specified in the XML Schema (Part 2) specification. For example, to specify a duration of 1 year, 2 months, 3 days, 10 hours, and 30 minutes, specify: P1Y2M3DT10H30M. You can also indicate a duration of minus 120 days as: -P120D. Reduced precision and truncated representations of this format are allowed provided they conform to the following: If the number of years, months, days, hours, minutes, or seconds in any expression equals zero, the number and its corresponding designator may be omitted. However, at least one number and its designator must be present. The seconds part may have a decimal fraction. The designator ‘T’ shall be absent if all of the time items are absent. The designator ‘P’ must always be present. For example, P1347Y, P1347M, and P1Y2MT2H are all allowed; P0Y1347M and P0Y1347M0D are allowed. P-1347M is not allowed although –P1347M is allowed. P1Y2MT is not allowed.
| ||
UDDIAuthTokenExpiration | The duration of an authorization token. This duration is specified using an xs:duration instance. It specifies a duration in terms of years (either 0 or 1), months, days, hours, minutes, and seconds. The default value is 1 day (xs:duration(P1D)). | ||
UDDITransferTokenExpiration | The duration of a transfer token. This duration is specified using an xs:duration instance. It specifies a duration in terms of years (either 0 or 1), months, days, hours, minutes, and seconds. The default value is 1 day (xs:duration(P1D)). | ||
UDDIV2Inquiry | Enables UDDI V2 Inquiry support. Valid values: true (default) or false. | ||
UDDIV2Publish | Enables UDDI V2 Publish support. Valid values: true (default) or false. | ||
UDDISendEmptyWebServiceNotifications | Specifies whether to allow Web service notifications to be sent even when no changes have occurred. Valid values: true (default) or false. | ||
UDDISendEmptyEmailNotifications | Specifies whether to allow email notifications to be sent even when no changes have occurred. Valid values: true or false (default). | ||
UDDIMinimalNotificationInterval | The minimum time interval at which to send notifications to subscribers. This duration is specified using an xs:duration instance. It specifies a duration in terms of years (either 0 or 1), months, days, hours, minutes, and seconds. The default value is 30 seconds (xs:duration(P30S)). The minimal resolution is 10 seconds (as well as the minimal possible value). | ||
UDDINumberOfRetries | The maximum number of times to try to send Web service notifications to subscribers. Valid values: 0 through 10. Default: 3. The value 0 turns off this property (that is, allows for unlimited retries).
| ||
UDDIMaxSubscriptionThreads | The maximum number of threads for subscriptions. Default: 5. |
Parameter | Description |
CENTRASITE-URL | (Optional). The URL of the CentraSite registry. For example, http://localhost:53307/CentraSite/CentraSite. |
USER-ID | The user ID of a registered CentraSite user who has the CentraSite Administrator role. For example, Administrator. |
PASSWORD | The password for the registered CentraSite user identified by the parameter USER-ID. |
CONFIG-FILE | The absolute or relative path to the XML configuration file. If relative, the path should be relative to the location from where the command is executed. |