Enabling Trace Logging for All JMS Triggers
You can configure Integration Server to generate additional debug and trace logging for all JMS triggers.
Note: | For the increased logging to appear in the server log, you must set the logging level for server facility 0134 JMS Subsystem to Trace. |
To enable debug trace logging for all JMS triggers
1. Open Integration Server Administrator if it is not already open.
2. In the Settings menu of the Navigation panel, click Extended.
3. Click Edit Extended Settings.
4. Under Extended Settings, type the following:
watt.server.jms.debugTrace=true
5. Click Save Changes.
6. Suspend and then enable all JMS triggers.
For information about suspending and enabling all JMS triggers at one time, see webMethods Integration Server Administrator’s Guide.