Configuring the Process Tracker Retrieval Interval
To configure the Process Tracker retrieval interval
1. Open this file in a text editor:
Software AG_directory \optimize\analysis\conf\ProcessTracking.xml
2. Locate the following section:
<entry key="modelRefreshInterval" type="Long">
<rendering-properties>
<property name="type" value="textfield"/>
<property name="size" value="25"/>
<property name="hidden" value="true"/>
</rendering-properties>
<value>300000</value>
</entry>
3. The retrieval interval is defined in the <value> element, with a default of 300000 milliseconds (five minutes). Type a new value in milliseconds, using a value of not less than 30000 (30 seconds).
Important: | Specifying a value of less than 30 seconds can cause serious disruption to normal operations of Process Tracker and the Analytic Engine. |
4. Save the file.
5. Stop and restart the Analytic Engine to apply the change.