Messages and Codes: General Messages - Set 1

INOAAE0001 Function not selected : name
Explanation

The server extension function is not selected so that the parameter cannot be modified.

Action

Select the server extension function first.


INOAAE0004 Cannot modify journal space
Explanation

The journal space of the specified database cannot be modified.

Action

Check whether the data space is already in use. Check the database location for remaining disk space.


INOAAE0018 Port number 'port' for 'name' indication
Explanation

The port number cannot be used.

Action

Change the port parameter value.


INOAAE0019 fail - delete database database name read only parameter is set
Explanation

The database parameter "read only" must be cleared before the database can deleted.

Action

Remove the read only flag in the database parameters.


INOAAE0022 count spaces successfully moved from old location to new location, one or more spaces couldn't be moved because of errors/warnings
Explanation

The given number of spaces were moved successfully but one or more spaces could not be moved because an error or a warning occurred during the execution of the command.

Action

Find out why spaces were not moved and try to move them via the 'Move' command of the database spaces entry.


INOAAE0032 Cannot activate dynamic property 'name'
Explanation

The property cannot be updated in the current server session, but will be active after a restart of the database.

Action

Restart the database to activate the property.


INOAAE0038 Cannot open file path, file does not exist or is opened by another one or not enough access rights
Explanation

The file does not exist or is already open.

Action

Check the filename.


INOAAE0039 Unknown database space number
Explanation

The database space number is not valid for this database.

Action

Use a valid database space number.


INOAAE0040 This command is valid for journal space only
Explanation

The database space type is not valid for this command.

Action

Use the journal space.


INOAAE0042 CD database information file not found
Explanation

The error message information file for the CD database not found.

Action

Check the path and filename.


INOAAE0043 CD database information file doesn't contain all necessary data or was created on a different platform
Explanation

The content of the information file is not complete or the file is not the required information file is from a different operating system.

Action

Check the content of the information file.


INOAAE0044 CD database from different operating system cannot be registered
Explanation

Only CD databases from the same operating system can be registered.

Action

Use a CD database that was created on the same operating system.


INOAAE0045 Operation not allowed on CD database or read only database
Explanation

The operation is not allowed on a CD database or read only database.

Action

No action required.


INOAAE0054 The "Add database space" function has failed
Explanation

The attempt to add one or more of the database spaces failed.

Action

Check the database locations for remaining disk space. The server property "read only" may be set to "yes".


INOAAE0055 More than one replication database is not yet supported
Explanation

Only one replication database is allowed.

Action

No action required.


INOAAE0056 Re-invert of database database name has failed
Explanation

The re-invert operation failed. Possible reasons are that the database is not active or, if active, one or more indices could not be repaired.

Action

Check your database status.


INOAAE0058 Invalid Access Control Element name
Explanation

Function names cannot be part of paths.

Action

Use either a function name or a path but not both.


INOAAE0059 Invalid master database name
Explanation

The master database name specified is invalid.

Action

Specify another database name for the master database.


INOAAE0060 Specification of key parameter is mandatory
Explanation

The parameter must be specified.

Action

Specify the parameter and try again.


INOAAE0065 Server extension 'name' not defined
Explanation

The specified server extension does not exist.

Action

No action required.


INOAAE0066 Internal configuration store key _default not found
Explanation

The default internal configuration store key could not be found.

Action

Please contact your software supplier.


INOAAE0067 File 'path' not found
Explanation

The specified file could not be found.

Action

Specify a valid filename.


INOAAE0068 Different server extension names: name is different from name
Explanation

The server extension names differ.

Action

No action required.


INOAAE0069 File 'path' not extracted
Explanation

The server extension installation file was not extracted.

Action

No action required.


INOAAE0070 File 'path' already installed
Explanation

The server extension installation file was previously installed.

Action

No action required.


INOAAE0072 Document 'path' not installed
Explanation

The server extension installation document was not installed.

Action

The action depends on previous error messages. Please check the previous messages for more information.


INOAAE0073 File 'path' not created
Explanation

The server extension installation file was not created.

Action

Correct the access rights for the directory and retry the operation.


INOAAE0074 Server extension name 'name' not defined
Explanation

The name of the server extension is not defined.

Action

Specify the name of the server extension and retry the operation.


INOAAE0075 Server extension name 'name' already defined
Explanation

The name of the server extension already exists.

Action

Change the name of the server extension and retry the operation.


INOAAE0076 Directory 'path' already exists
Explanation

The server extension installation directory already exists.

Action

Remove the directory and retry the operation.


INOAAE0077 Document 'path' already installed
Explanation

The server extension installation document is already installed.

Action

Remove the server extension installation document.


INOAAE0078 Execution failed: command
Explanation

The specified operating system command failed.

Action

The action depends on previous error messages. Please check the previous messages for more information.


INOAAE0079 Database name not defined
Explanation

The required database name was not specified.

Action

Please contact your software supplier.


INOAAE0080 No functions defined: name
Explanation

There are no functions defined in the server extension.

Action

Add functions to the server extension and retry the installation.


INOAAE0081 The Tamino server returned an invalid server extension response document
Explanation

The server extension response document does not correspond to the agreed protocol with the Tamino server.

Action

Please contact your software supplier.


INOAAE0082 Server extension 'name' does not exist
Explanation

The specified server extension does not exist.

Action

Correct the name of the server extension and retry the operation.


INOAAE0083 File 'path' already open
Explanation

The server extension installation package is already open.

Action

Wait until the package is not being used and retry the operation.


INOAAE0084 File 'path' not open
Explanation

The server extension installation package is not open.

Action

Wait until the package is not being used and retry the operation.


INOAAE0085 File 'path' not previously closed
Explanation

The server extension installation package is not closed.

Action

Wait until the package is not being used and retry the operation.


INOAAE0086 Operation 'type' not implemented
Explanation

The requested operation is not implemented.

Action

No action required.


INOAAE0087 Command 'type' not allowed
Explanation

This command is not allowed for the requested server extension.

Action

Ensure that you use one of the commands allowed for the server extension.


INOAAE0088 message
Explanation

This is a generic container for Tamino error messages.

Action

See the content of the message during online Tamino operation for further information.


INOAAE0089 Not an installation package: path
Explanation

The provided file is not a server extension installation package.

Action

Use a valid installation package.


INOAAE0092 Error during write to inodmn, write interrupted or socket closed by inodmn
Explanation

This is an internal error. It could be caused by not fully compatible versions of Tamino and System Management Hub.

Action

Please contact your software supplier.


INOAAE0093 Error during read from inodmn, read interrupted or socket closed by inodmn
Explanation

This is an internal error. It could be caused by not fully compatible versions of Tamino and System Management Hub.

Action

Please contact your software supplier.


INOAAE0094 Command is an illegal number
Explanation

This is an internal error in the event logging protocol.

Action

Please contact your software supplier.


INOAAE0095 This command requires a different database state
Explanation

An attempt was made to execute a command that either requires an active database, but the database is inactive, or the command can be executed only in inactive mode, but the database is active.

Action

Start or stop the database to bring it into the appropriate mode (active or inactive) and retry the command.


INOAAE0096 The command requested cannot be executed because it is already running
Explanation

The command you wish to execute is already being executed by someone else, but the command cannot be executed in parallel.

Action

Wait until the running command has completed. The argevsrv process keeps track of running commands. If the command is blocked although it is obviously not running, try restarting the argevsrv process.


INOAAE0097 Insufficient resources to complete the command
Explanation

This is an internal error in the event logging protocol. Some resource (usually disk or main storage) is exhausted and the function failed to complete.

Action

Check if there is enough free disk space. Delete temporary and otherwise expandable files, then try again.


INOAAE0098 Path 'path/name' not created
Explanation

The specified path name is too long.

Action

Choose another file structure with shorter path names.


INOAAE0099 Path 'path' not converted
Explanation

The specified path name was not converted to a URL or vice versa. Either the path name or the URL is too long.

Action

Choose another file structure with shorter path names.


INOAAE0110 Internal error with database startup by changing replication database to a normal database
Explanation

An internal error occurred when starting the database.

Action

Please contact your software supplier.


INOAAE0111 No valid destination directory for backup files given.
Explanation

No valid destination directory was given.

Action

Specify at least one valid directory with write access for Tamino and enough space for the backups.


INOAAE0113 Path 'path' not extracted
Explanation

The specified path was not extracted from the internal configuration store. This is an internal error.

Action

Please contact your software supplier.


INOAAE0114 Execution mode 'name' not extracted
Explanation

This is an internal error.

Action

Please contact your software supplier.


INOAAE0115 Execution mode not compatible: mode != mode
Explanation

The specified execution modes are not compatible.

Action

Select a compatible execution mode.


INOAAE0116 GUID not extracted
Explanation

The GUID was not extracted from the internal configuration store. This is an internal error.

Action

Please contact your software supplier.


INOAAE0117 DLL 'path' is not registered
Explanation

The specified DLL cannot be used.

Action

Specify another DLL.


INOAAE0118 DLL 'path' not unregistered
Explanation

The specified DLL cannot be used.

Action

Specify another DLL.


INOAAE0119 Remove of all server extensions failed
Explanation

The server extensions could not be removed.

Action

Check the extensions.


INOAAE0120 XML port not defined for database 'name'
Explanation

The XML port value is missing in the internal configuration store.

Action

Please contact your software supplier.


INOAAE0121 Not enough memory
Explanation

There is not enough memory for an http request.

Action

Close some of your applications.


INOAAE0122 XML template processing failed, template template missing or incorrect
Explanation

This is an internal error of the Tamino Manager browser interface.

Action

Check if the quoted template file exists and if it is intact. If not, either reinstall or contact your software supplier.


INOAAE0123 No package name defined: name
Explanation

For a server extension the Java package name is required.

Action

If you generated the Java package yourself, use a unique name for your Java package. If it is a third-party product, get a new package from your software vendor.


INOAAE0124 Unknown database database name : rename failed or no information from Software AG XTS Directory Server
Explanation

The database to be renamed could not be found.

Action

Check if the specified database exists and if the Software AG XTS Directory Server is running.


INOAAE0125 Directory 'path' not deleted
Explanation

The directory is in use. Therefore it cannot be deleted.

Action

Wait until the directory is no longer in use and try again.


INOAAE0126 No valid location type found
Explanation

The location type parameter is missing.

Action

Specify the location type parameter.


INOAAE0127 Location type 'type' is unknown
Explanation

An unknown location type is specified.

Action

Specify a valid location type.


INOAAE0128 File 'path' not copied
Explanation

The specified file was not copied to the target file.

Action

Check your permissions or check your disk space.


INOAAE0129 Please specify at least the location path
Explanation

The path parameter is missing.

Action

Specify the path parameter.


INOAAE0130 Path path exceeds the maximum path length of number characters
Explanation

The length of the specified path exceeds the allowed maximum length of a directory path.

Action

Specify a shorter directory path.


INOAAE0131 Location path path includes no valid directory
Explanation

The root of the specified directory path is invalid. A possible cause is that the specified directory path could be on a removable drive or RAM disk.

Action

Specify a valid directory path.


INOAAE0132 Location path path is located on a remote drive. Please choose a local drive.
Explanation

A remote drive is not allowed for a location path.

Action

Specify the location path on a local drive.


INOAAE0133 Name name exceeds the maximum name length of number characters
Explanation

The length of the specified name exceeds the allowed maximum length.

Action

Specify a shorter name.


INOAAE0134 Name name already exists as database location name
Explanation

The specified location name is the name of an existing database location.

Action

Change the location name.


INOAAE0135 Path path already exists as database location path
Explanation

The specified location path is the path of an existing database location.

Action

Change the location path specification.


INOAAE0136 Database location name not found
Explanation

The specified location name was not found in the internal configuration store.

Action

Specify an existing location name.


INOAAE0137 Location name is the current default location
Explanation

Deleting the current default location is not allowed.

Action

Change the default location.


INOAAE0138 Location name is the current default backup location
Explanation

Deleting the current default backup location is not allowed.

Action

Change the default backup location.


INOAAE0140 Database database name uses database location name with location path path as 'category'. If you still want to delete the location, all spaces from that location must be moved to another location before you can delete it.
Explanation

The specified location is defined as a category location for a database, so deleting is not allowed. Move the database spaces on that location to another one.

Action

Change the default database location category specification.


INOAAE0141 No response document received
Explanation

There was no response document received from the server.

Action

Check if the network communication is established.


INOAAE0142 Value for property 'name' too small - minimum is minimum value
Explanation

The value for the given property is smaller than the minimum allowed.

Action

Specify a larger value.


INOAAE0143 Value for property 'name' too large - maximum is maximum value
Explanation

The value is larger than the maximum allowed.

Action

Specify a smaller value.


INOAAE0144 Invalid numeric value for property 'name'
Explanation

The property is a numeric property and the value has the wrong type.

Action

Change the property value to numeric.


INOAAE0145 Property 'name' must be 'yes' or 'no'
Explanation

The property is a boolean property and the value has the wrong type.

Action

Change the property value to 'yes' or 'no'.


INOAAE0146 The sequence of backup spaces is not complete.
Explanation

One or more streams or extents are missing in the selected backup spaces. Only complete backups can be restored. Spaces missing at the end of the sequence will be only detected at runtime when data is loaded into the new database.

Action

Check the stream or extent numbers of the selected backup spaces and add missing spaces. Check if the sequence of backup spaces (Extent 1, Extent 2, ..) is correct.


INOAAE0149 Web server name already assigned
Explanation

The web server is already assigned to the specified database.

Action

Check the specified web servers and the web server assignments.


INOAAE0153 Web server name not assigned
Explanation

The specified web server is not assigned to the specified database, therefore the assignment cannot be deleted.

Action

Check the web server assignments to the specified database.


INOAAE0154 Error retrieving collection/doctype information: the requested document(s) could not be locked
Explanation

The document is already locked or cannot be locked. A possible reason can also be an unclosed session.

Action

Wait for a short time and try this command again.


INOAAE0155 Unknown location location name
Explanation

The given location does not exist.

Action

Choose a valid location.


INOAAE0157 Parameter parameter name missing
Explanation

The parameter with the given name is not specified.

Action

Specify the required parameter.


INOAAE0158 parameter name: invalid path, directory does not exist or is not writable
Explanation

The given path does not exist or is not writeable.

Action

Use a path that exists and is writable.


INOAAE0159 Database database name already exists
Explanation

The "rename database" command failed because the database name already exists.

Action

Use a different name or remove the database.


INOAAE0162 Cannot delete database space space number
Explanation

The specified database space cannot be deleted from the location.

Action

Check whether the database space is already in use.


INOAAE0165 Cannot expand database space space number
Explanation

The specified database space cannot be expanded.

Action

Check whether the database space is already in use. Check the database location for remaining disk space. If the database is read-only it cannot be expanded.


INOAAE0169 Database database name exists
Explanation

A database with the same name exists either on the local computer, or in the scope of XTS Directory Service (which may know databases on multiple computers).

Action

Choose a different name. On Windows platforms, it is not sufficient to have two names differ only in upper/lowercase.


INOAAE0170 Configuration 'configuration' already exists for external backup method 'method'
Explanation

The configuration name already exists for this external backup method.

Action

Specify a new configuration name which does not exist already.


INOAAE0174 Could not initialize TCP stack
Explanation

This is an internal error in the event logging protocol. The communication between a logging client and the logging server could not be established. Basic functions and commands may be unaffected by this failure but messages will not be stored permanently or displayed in the Tamino Manager browser interface.

Action

This failure is most likely due to extreme shortage of resources, or missing operating system components. Check the disk space. Check the integrity of the installation. Contact you software supplier to check if there is a software update.


INOAAE0175 Error in inodmn conversation: unexpected response buffer
Explanation

This is an internal error of the event logging protocol.

Action

Please contact your software supplier.


INOAAE0177 Error in inodmn conversation: invalid number
Explanation

This is an internal error in the event logging protocol.

Action

Please contact your software supplier.


INOAAE0178 Function not implemented
Explanation

This is an internal error of the event logging protocol, a feature is not implemented in the version installed. Basic functions and commands are probably not affected.

Action

No action necessary. Please contact your software supplier for a possible software update.


INOAAE0179 Error in inodmn conversation: request failed
Explanation

This is an internal error in the event logging protocol. It could be caused by not fully compatible Tamino and System Management Hub versions.

Action

Please contact your software supplier for a possible software update.


INOAAE0180 Too many parameters
Explanation

A parameter has been specified repeatedly, but is only allowed once.

Action

Change the command and retry.


INOAAE0181 Database does not exist
Explanation

There is no database with the given name.

Action

Choose a valid database name.


INOAAE0182 Space space is not a valid backup space
Explanation

The file or tape specified has not been recognized as a valid Tamino backup. The file or tape could be damaged or access to the medium could be denied.

Action

Use a valid backup space.


INOAAE0183 Backup spaces have not been specified in the sequence determined by their extent or stream numbers
Explanation

The spaces are not ordered by their extent or stream number. The first space does not have the extent number 1.

Action

Specify backup spaces in the order of the extent or stream number.


INOAAE0184 Creation of directory path failed
Explanation

The directory at the given path could not be created.

Action

Check the permissions for the given path.


INOAAE0186 Unknown command
Explanation

The command is unknown in this context.

Action

Specify a valid command for this context.


INOAAE0187 Missing parameter
Explanation

A parameter specification is missing.

Action

Specify the needed parameter.


INOAAE0188 Not allowed to set a location of type 'type' as default location
Explanation

The location represents a type which is not allowed to be set as the default location.

Action

Set another location as the default location.


INOAAE0189 No valid location category specified
Explanation

The specified category is not a valid location category.

Action

Specify a valid location category.


INOAAE0190 Memory fault
Explanation

An error has occurred while allocating memory storage.

Action

Reboot the system.


INOAAE0191 database space space number at location old location not found
Explanation

A database space cannot be moved from one location to another, because the space does not exist at the source location.

Action

Search for the space at another location.


INOAAE0192 database space space number at location new location already exists
Explanation

The database space cannot be moved to the new location. The space already exists.

Action

Delete the space from the new location.


INOAAE0193 Cannot remove database space space number from location name
Explanation

A database space cannot be removed from the source location.

Action

Check the permissions for the database space. The database space could be in use by a running database. Do a shutdown of the database and try again.


INOAAE0194 Cannot write internal configuration store
Explanation

The write operation into the internal configuration store failed.

Action

Check the permissions.


INOAAE0195 Unknown database database name or no information from Software AG XTS Directory Server
Explanation

The database is unknown or there is no information from the Software AG XTS Directory Server.

Action

Check the database name, and check if the Software AG XTS Directory Server is running.


INOAAE0196 Database database name ID or port not found
Explanation

The database ID or port was not found in the internal configuration store.

Action

Please contact your software supplier.


INOAAE0197 Database database name already active
Explanation

The database is already active.

Action

Stop the database and re-execute the operation.


INOAAE0198 Database database name not active
Explanation

The database is not active.

Action

Start the database and re-execute the operation.


INOAAE0203 Function 'name' not found
Explanation

The function was deleted, but the display has not been refreshed.

Action

Refresh your display.


INOAAE0204 Invalid function type 'type'
Explanation

The type of a server extension function was invalid. This is an internal error.

Action

Please contact your software supplier.


INOAAE0205 File 'path' not added
Explanation

The file was not added to the server extension package. This is an internal error.

Action

Please contact your software supplier.


INOAAE0208 Not allowed to specify a recoverydate with recoveryoption=no
Explanation

If a recoverydate is specified, recoveryoption=no is not allowed.

Action

Specify recoveryoption=yes or do not use the recoveryoption parameter.


INOAAE0209 Access Violation - You are not allowed to access the requested database
Explanation

You are not authorized to access the database.

Action

Get authorization from the database administrator.


INOAAE0210 Min Port must be lower than Max Port and Port Ranges cannot overlap
Explanation

An invalid port range was specified. Min Port must be lower than Max Port and Port Ranges cannot overlap.

Action

Change the ports and retry the operation.


INOAAE0212 Error reading database locations
Explanation

An error occurred while reading database locations from the internal configuration store.

Action

Please contact your software supplier.


INOAAE0215 Unknown category
Explanation

The agent was called with an invalid category.

Action

Use a valid category for this agent.


INOAAE0216 Missing database name
Explanation

The database name is missing in the object ID.

Action

Use a valid object ID.


INOAAE0217 Missing Object ID
Explanation

The object ID is missing in the agent call parameter.

Action

Use a valid object ID.


INOAAE0218 Missing database space type
Explanation

The database space type is missing in the agent call parameter.

Action

Use a valid database space type.


INOAAE0219 Unknown database space category
Explanation

The database space category in the agent call parameter is unknown.

Action

Use a valid database space category .


INOAAE0220 The database database name does not exist
Explanation

One of the following errors may have occurred: - XTS not configured in the "hosts" file - the XTS service not running - the database is not specified in the XTS configuration file xtsurl.cfg.

Action

Choose another database name, check XTS configuration.


INOAAE0222 The database database name must be offline
Explanation

The database must be stopped for this operation.

Action

Shut down the database.


INOAAE0225 Leave command request on Event Service failed
Explanation

This request is part of the command synchronization scheme. This scheme synchronizes the execution of commands that might interfere otherwise and it prevents parallel execution of commands that should be executed only once per database at a time (like a backup).

Action

Check if the Event Service is running. If it is running, stop and re-start the service to initialize command synchronization


INOAAE0226 Database status request on event demon failed
Explanation

The status of a database could not be received from the event demon.

Action

Check if the event demon is running.


INOAAE0229 Tape path does not exist
Explanation

The tape with the specified path does not exist.

Action

Specify an existing tape path.


INOAAE0230 Device path does not exist
Explanation

The device with the specified path does not exist.

Action

Specify an existing device path.


INOAAE0231 Could not create location name at path
Explanation

Creating the location failed because of an internal configuration store error.

Action

Check access rights (privileges) of the connected user; the user must be a power user (administrator).


INOAAE0232 Could not delete location name
Explanation

Deleting the location failed because of an internal configuration store error.

Action

Please contact your software supplier.


INOAAE0233 Could not rename location name to name
Explanation

Renaming the location failed because of an internal configuration store error.

Action

Please contact your software supplier.


INOAAE0234 Could not set location name as default database location
Explanation

Setting the location as the default location failed because of an internal configuration store error.

Action

Please contact your software supplier.


INOAAE0235 Could not set location name as default backup database location
Explanation

Setting the location as the default backup location failed because of an internal configuration store error.

Action

Please contact your software supplier.


INOAAE0236 Could not modify default of database location category 'category'
Explanation

Modifying the default database location category failed because of an internal configuration store error.

Action

Please contact your software supplier.


INOAAE0238 Archive path is empty
Explanation

The archive is empty or corrupt. Try with a correct archive.

Action

Correct the archive you want to work with.


INOAAE0242 No database name specified
Explanation

The database name must be specified.

Action

Specify the database name.


INOAAE0243 database registration failed
Explanation

The registration of a read only database failed.

Action

Check the source file/path and database name.


INOAAE0268 Move command for location type 'type' not supported
Explanation

The move command is not supported for some location types, especially tape.

Action

Specify a valid location type as the target of the move command.


INOAAE0272 Backup date 'backup date' specifies no valid backup set for database database name
Explanation

The given date was not found as a savepoint entry in the internal configuration store.

Action

Specify a valid date which corresponds to a valid savepoint entry in the internal configuration store.


INOAAE0274 No collection name specified
Explanation

The collection name must be specified for this operation.

Action

Specify the collection name.


INOAAE0284 Unregister is not allowed for normal databases; use "delete" command
Explanation

Use the "delete" command to remove a normal database.

Action

Use the batch command "delete" instead of "unregister".


INOAAE0285 Delete is not allowed for CD databases; use "unregister" command
Explanation

Use the "unregister" command to remove a CD database.

Action

Use the batch command "unregister" instead of "delete".


INOAAE0287 External function name exceeds 80 characters
Explanation

The length of the external function name may not exceed 80 characters.

Action

Specify a shorter function name.


INOAAE0294 No file restored : name
Explanation

No file was restored. Maybe there are no server extensions installed.

Action

If there are server extensions installed check your database.


INOAAE0295 Directory not created : path
Explanation

The specified directory was not created.

Action

Check the permissions of your file system.


INOAAE0296 Directory not found : path
Explanation

The specified directory was not found.

Action

Check the permissions of your file system.


INOAAE0297 Database not running : name
Explanation

The specified database is not running.

Action

Start the database.


INOAAE0298 Server returned error code : type
Explanation

The Tamino server returned an error code.

Action

Please contact your software supplier.


INOAAE0304 Fail - command log switch to mode buffers buffers
Explanation

This is a result message for a batch command.

Action

Check the database.


INOAAE0305 Parameter not defined : name
Explanation

No value given for a mandatory parameter.

Action

Retry the command with the specified parameter value.


INOAAE0306 Invalid object identification : name
Explanation

The given object identification is invalid.

Action

Retry the command with a correct object identification.


INOAAE0307 Update of settings failed : name
Explanation

The update of the given settings parameter failed.

Action

Check the job log for further information.


INOAAE0310 Path exists; please remove it or use another one
Explanation

This is an error message for creating a CD database in batch mode. A specified pathname exists already, so a different pathname must be supplied or the existing path must be removed.

Action

Remove the path or use another one.


INOAAE0311 Invalid character used in the specified location name at position position
Explanation

An invalid character has been specified in the location name. This can be a non-ASCII character or one of the special characters " %&,;!\=#[]\"\<>`'".

Action

Change the character.


INOAAE0312 Invalid character used in the specified path at position position
Explanation

An invalid character has been specified in the given path. This can be a non-ASCII character or one of the special characters "\/:*?\"<>|&`" for Windows or ":*? \"<>|;,&!\`'" for all other operating systems.

Action

Change the character.


INOAAE0313 Mapped documents exist : name
Explanation

Mapped XML documents exist for the server extension.

Action

Delete the XML documents before uninstalling the server extension.


INOAAE0314 Command not allowed if no function is selected
Explanation

The server extension must contain at least one selected function.

Action

Select some functions from the object being packed.


INOAAE0315 Database name contains invalid character "&" (ampersand)
Explanation

A database name can't contain the "&" character.

Action

Remove the "&" from the database name.


INOAAE0347 Database could not be connected
Explanation

The security manager could not connect to Tamino.

Action

Check if the database has been started.


INOAAE0355 The first and last character of a name should not be a blank
Explanation

Blanks are not allowed at the beginning and end of a name.

Action

Change the first/last character.


INOAAE0356 ACL name contains invalid character:
Explanation

Special characters are not allowed.

Action

Remove special characters from ACL name.


INOAAE0359 Group name contains invalid allowed character:
Explanation

Special characters are not allowed.

Action

Remove special characters from the group name.


INOAAE0361 User ID contains invalid character:
Explanation

Special characters are not allowed.

Action

Remove special characters from the user ID.


INOAAE0362 User created with escaped XML special characters in description
Explanation

XML special characters are not allowed.

Action

Remove special characters from the description.


INOAAE0363 Special characters are not allowed in an ACE name:
Explanation

Special characters are not allowed in an ACE name.

Action

Remove special character from ACE name.


INOAAE0370 TSM@DLL PARSE_ERR
Explanation

The retrieved XML-document is invalid or the XML parser could not retrieve data.

Action

Shut down the database and restart it.


INOAAE0372 TSM@DLL UNKNOWN ACL OR ACL NOT RETRIEVABLE
Explanation

The mentioned ACL is no longer available. Maybe another concurrent session deleted it.

Action

Refresh the data within the Tamino Manager and try again.


INOAAE0373 TSM@DLL UNKNOWN GROUP
Explanation

The mentioned GROUP is no longer available. Maybe another concurrent session deleted it.

Action

Refresh the data within the Tamino Manager and try again


INOAAE0377 Access control element 'name' already exists in access control list
Explanation

The access control element already exists in an access control list.

Action

Change the name of the access control element.


INOAAE0378 Version with compatibility level level of Tamino not found
Explanation

For reading the backup, a Tamino version of the same compatibility level is required.

Action

Install a Tamino version of the required compatibility level.


INOAAE0381 No container size information in backup file filename found
Explanation

The backup file does not contain important information for restoring.

Action

Check the backup file or generate a new one.


INOAAE0382 Not enough free memory
Explanation

Not enough free memory.

Action

try closing other applications to free memory.


INOAAE0386 Access Control List 'name' already exists
Explanation

An access control list with the specified name already exists.

Action

Change the name of the access control list.


INOAAE0387 User 'name' already exists
Explanation

The given user already exists in the ino:user doctype.

Action

Supply a new user ID.


INOAAE0388 User 'name' does not exist
Explanation

The user ID has not been found in the ino:user doctype.

Action

Create the required user ID.


INOAAE0389 Access control list 'name' does not exist
Explanation

The access control list has not been found in the ino:acl doctype.

Action

Create the required access control list.


INOAAE0390 User group 'name' does not exist
Explanation

A user group with the given name has not been found in the ino:group doctype.

Action

Create the required group.


INOAAE0391 Acename has not been defined
Explanation

The command line parameter "acename" has not been provided.

Action

Provide the "acename" parameter.


INOAAE0392 Permission has not been defined
Explanation

The command line parameter "permission" has not been provided.

Action

Provide the parameter "permission".


INOAAE0393 Aclname has not been defined
Explanation

The command line parameter "aclname" has not been provided.

Action

Provide the parameter "aclname".


INOAAE0394 Database is readonly
Explanation

The database is readonly, updates are not possible.

Action

No action required.


INOAAE0395 UserID has not been defined
Explanation

The command line parameter "userid" has not been provided.

Action

Provide the parameter "userid".


INOAAE0396 Groupname has not been defined
Explanation

The command line parameter "groupname" has not been provided.

Action

Provide the parameter "groupname".


INOAAE0397 Ace permission is not defined
Explanation

The permission for the access control element is not defined.

Action

Provide the permission for the access control element.


INOAAE0398 Permission has to be set to an allowed value
Explanation

Permission has not been set to an allowed value.

Action

Set permission to an allowed value.


INOAAE0399 Description has not been defined
Explanation

Description has not been provided.

Action

Provide description.


INOAAE0400 User group 'name' already exists
Explanation

The usr group already exists in the ino:group doctype.

Action

Change the group name to one that does not already exist.


INOAAE0401 Missing compatibility level : type
Explanation

The source or target compatibility level was not specified.

Action

Specify the compatibility level and execute the command again.


INOAAE0402 Set database version failed
Explanation

The "set database" action failed. Read the error messages to get more information.

Action

Check the error messages that are generated before this message at runtime to get the reason.


INOAAE0408 Some databases may be still active at system shutdown
Explanation

An error occurred while all active databases were stopped.

Action

Shut down manually all active databases prior to the system shutdown; get assistance from your software supplier to fix the problems that were reported.


INOAAE0412 This request is in conflict with another request that is currently being executed
Explanation

Some commands that access the same resources are mutually exclusive. This message can also appear if a process has been killed with operating system means or has crashed while the crash held the critical section locked.

Action

Retry later. If no other command is active and no one else is currently executing administrative commands, shut down and restart the System Management Hub Event Layer Service.


INOAAE0413 The request cannot be executed because a condition is missing
Explanation

The request requires another command to be active.

Action

No action possible. Please contact your software supplier.


INOAAE0414 Restore of database database name failed
Explanation

An error occurred while restoring the specified database.

Action

Try to detect the error, otherwise contact your software supplier.


INOAAE0417 Web server 'name' does not exist
Explanation

The IP address and/or port of web server cannot be changed; the specified web server does not exist.

Action

Use an existing web server.


INOAAE0418 IP address of web server 'name' is invalid
Explanation

The IP address of the web server is invalid.

Action

Specify the IP address in a valid format.


INOAAE0419 File 'path' already exists
Explanation

The server extension installation file already exists.

Action

Select another path name.


INOAAE0423 Unable to execute command with version 'version' for database from version 'version'. Please use 'version=version' parameter for argbatch command, or change your environment : 'argbatch set environment version=version'.
Explanation

A Tamino agent was called from the wrong version.

Action

Use the "version" parameter for the argbatch command or change your environment with: "argbatch set environment version=...".


INOAAE0428 Web server 'name' not defined
Explanation

The specified web server is not defined in the web server management.

Action

Add the specified web server in the web server management.


INOAAE0439 Tamino plug-in for argevsrv not installed or not properly initialized
Explanation

The Tamino plug-in was not installed, or the System Management Hub Event Service was unable to load it. Tamino will work without it but some administrative commands will not be be synchronized. This will cause problems only in rare conditions when multiple databases are created at the same time on the same computer.

Action

Avoid creating multiple databases at the same time on the same computer; please contact your software supplier to find out why the Tamino plug-in was not loaded by the System Management Hub Event Service.


INOAAE0441 version of database not found
Explanation

The database was found but not the version of Tamino that it requires.

Action

Check if the correct Tamino version for database is installed or set the version to one installed on the machine.


INOAAE0442 Tamino version not found
Explanation

The specified Tamino version was not found.

Action

Check if the Tamino version is installed on the machine.


INOAAE0443 highest Tamino version not found
Explanation

The highest Tamino version was not found.

Action

Check if Tamino is installed on the machine


INOAAE0444 Max and/or Min port not found or RGS error
Explanation

The Max and/or Min port was not found, or there was an RGS error.

Action

Please contact your software supplier.


INOAAE0456 The "Move database space" function failed
Explanation

An attempt to move a database space failed. Additional information is supplied in error messages that have occurred earlier.

Action

Please follow the actions of the error messages displayed earlier in the same job log.


INOAAE0459 The "Create Database" function failed
Explanation

An attempt to create a database failed. Additional information is supplied in error messages that have occurred earlier.

Action

Please follow the actions of the error messages displayed earlier in the same job log.


INOAAE0462 The "Delete Database" function failed
Explanation

An attempt to delete a database failed. Additional information is supplied in error messages that have occurred earlier.

Action

No action required. Please follow the actions of the error messages displayed earlier in the same job log.


INOAAE0472 Backup of database database name failed
Explanation

Errors occurred while backing up the specified database. A possible reason could be low system memory.

Action

Try to detect the error, otherwise contact your software supplier.


INOAAE0474 Start of database database name failed
Explanation

Errors occurred while starting the database.

Action

Try to detect the error, otherwise contact your software supplier.


INOAAE0475 Stop of database database name failed
Explanation

Errors occurred while stopping the specified database.

Action

If you cannot identify the error from a previous error message, please contact your software supplier.


INOAAE0480 Add database space space number to location new location failed
Explanation

An attempt to add database spaces to the specified location failed.

Action

No action required.


INOAAE0481 Not enough space on location new location
Explanation

The new location to which the database space should be moved is not big enough.

Action

Choose a larger location for moving the database space.


INOAAE0491 Error(s) occurred during modify of database properties
Explanation

An error occurred while attempting to modify database properties. Only the properties with an error message or a warning were not modified. All other properties are changed.

Action

Please contact your software supplier.


INOAAE0509 External function name already used : name
Explanation

The external name of a server extension function is already in use.

Action

Change the external function name and retry the operation.


INOAAE0510 Java classpath not modified : text
Explanation

The Java classpath was not modified according to the modification rules.

Action

Correct the modification parameters and retry the operation.


INOAAE0534 File 'path' not deleted
Explanation

The server extension DLL file could not be deleted.

Action

Delete the DLL manually.


INOAAE0547 Directory path does not exist
Explanation

The directory with the specified path does not exist.

Action

Specify an existing path.


INOAAE0548 No location name specified
Explanation

No location name was specified.

Action

Specify a location name.


INOAAE0549 Character '\' not allowed as part of location name
Explanation

The character '\' is not allowed as part of the location name, because this name is used as internal configuration store key, and the '\' is the internal configuration store key delimiter.

Action

Replace this character by another one.


INOAAE0567 There is currently only one location defined. Please create at least one more file system location using the Location Management 'Add' command.
Explanation

No second location is defined that can be used as destination location for the move command .

Action

Create a second location and then start this command again.


INOAAE0605 Wrong date or date format. Format 'string' required.
Explanation

An invalid date is specified or an invalid date format is used.

Action

Specify a valid date (use same format as used in 'argbatch show backups').


INOAAE0608 No other Tamino version installed, set version not possible
Explanation

Because there is no other Tamino version installed, it makes no sense to change the version.

Action

No action required.


INOAAE0611 Named pipe path does not exist
Explanation

The named pipe with the specified path does not exist.

Action

Specify an existing named pipe path.


INOAAE0619 Device path is not a named pipe
Explanation

The specified path is not a named pipe.

Action

Specify an existing named pipe path.


INOAAE0637 Directory name 'path' not compatible with object identification 'name'
Explanation

The directory name must consist of the first part of the object identification.

Action

Create a new server extension package with the correct directory name.


INOAAE0638 Server extension function 'name' does not exist
Explanation

The specified server extension function does not exist.

Action

Correct the function name.


INOAAE0639 Server extension function parameter 'name' does not exist
Explanation

The specified server extension function parameter does not exist.

Action

Correct the parameter name.


INOAAE0641 Internal error from DSIF interface name returncode return code error number error number
Explanation

This is an internal error message.

Action

Please contact your software supplier.


INOAAE0645 Stop of XML session 'session' failed
Explanation

Errors occurred while stopping the specified XML session.

Action

Try to detect the error, otherwise contact your software supplier.


INOAAE0646 Error reading backup methods for database database name
Explanation

No backup methods were found in the internal configuration store for the database.

Action

Please contact your software supplier.


INOAAE0648 Error reading parameters of backup method 'method'
Explanation

No parameters were found for the backup method in the internal configuration store.

Action

Please contact your software supplier.


INOAAE0651 Could not set global parameters for external backup method 'method' of database database name
Explanation

Setting of global parameters failed because of an internal configuration store error.

Action

Please contact your software supplier.


INOAAE0653 Could not set configuration parameters for external backup method 'method' of database database name
Explanation

Setting of configuration parameters failed because of an internal configuration store error.

Action

Please contact your software supplier.


INOAAE0656 Could not delete configuration 'configuration' of method 'method' of database database name
Explanation

The deletion of the configuration failed.

Action

Please contact your software supplier.


INOAAE0658 Error reading configurations for database database name of backup method 'method'
Explanation

An error occurred while reading the configuration data.

Action

Please contact your software supplier.


INOAAE0659 No configuration found for database database name of backup method 'method'
Explanation

No configuration data was specified for this method and database.

Action

Specify configuration data for this method and database using the 'External Backup Environment' dialog.


INOAAE0660 Replication database name expected
Explanation

The replication database name must be specified for this function.

Action

Specify the replication database name


INOAAE0662 The database database name cannot be added into the permission list
Explanation

An error occurred while adding the replication database name to the permission list.

Action

Check the subsequent error messages for more details.


INOAAE0665 Database database cannot be set as replication database
Explanation

An error occurred during the type change. The database cannot be set to a replication database. Possible reason: This database is a master database.

Action

Check for related additional messages.


INOAAE0667 Replication database database cannot be reset to normal type
Explanation

The database cannot be reset to a normal database.

Action

See the subsequent error messages.


INOAAE0668 Database database name is not active or is not a master database
Explanation

The master database must be in the active state or permit this database to be replicated.

Action

Start up the master database and check the permission list for replication databases.


INOAAE0669 Replication of master database database name is not permitted
Explanation

Permission to replicate the master database was denied.

Action

Ask the administrator to permit replication access to the master database.


INOAAE0672 Not enough space at location new location for additional new size MB - maximum free is free size MB
Explanation

The new location to which the database space should be moved or added is not big enough.

Action

Choose a larger location for the database space operation.


INOAAE0680 Backup(s) not found wrong backups please use one of the following backups
Explanation

Wrong backups were specified.

Action

Use only valid backups of the database. You can see all backups with the command "argbatch show backups database=mydatabase".


INOAAE0681 At least one backup must be given or don't use keepbackups
Explanation

For the option keepbackups, at least one backup must be given/selected.

Action

Give/select at least one backup.


INOAAE0683 Switching log space for database database name has failed
Explanation

Errors occurred while switching log space for the database.

Action

Try to detect the error, otherwise contact your software supplier.


INOAAE0684 At least one destination directory must be given with parameter "destinationdirectory_0"
Explanation

the option "keep backup files" needs at least one destination directory.

Action

Specify a destination directory with the parameter "destinationdirectory_0".


INOAAE0685 For option "keepbackups=selected" at least one backup date and at least one destination directory must be given with parameter "destinationdirectory_0", "backupdate_0"
Explanation

Give at least one backup date and one destination directory in the parameter list.

Action

Use the parameter "backupdate_0" to specify a backup to be kept and "destinationdirectory_0" for the destination directory.


INOAAE0691 Could not add backup method 'method' for database database name
Explanation

Adding the backup method failed because of an internal configuration store error.

Action

Please contact your software supplier.


INOAAE0694 Could not delete method 'method' of database database name
Explanation

Deleting the backup method failed because of an internal configuration store error.

Action

Please contact your software supplier.


INOAAE0696 Internal error error number during modify property 'name' to 'value'
Explanation

An error occurred while setting a new property value.

Action

Please contact your software supplier.


INOAAE0699 Deletion of backup 'backup date' of database database name failed
Explanation

An error occurred while deleting the specified backup.

Action

Check the additional messages.


INOAAE0707 No permission to modify the type of the database
Explanation

To change the type of a database to a replication database or to set it back to a normal one, the user needs to have administrator rights. Other possible reason: The database is not allowed to replicate the master database.

Action

Log in as administrator and try the operation again and check whether this database is in the permission list of the master database.


INOAAE0708 Update server sessions exist
Explanation

The database has already update sessions so that it cannot be used to replicate another database.

Action

Use a newly created database and retry this operation.


INOAAE0725 Error while changing port ranges
Explanation

An error occurred while changing the port ranges.

Action

Please contact you software supplier.


INOAAE0727 path is not a raw section
Explanation

The specified path must be a raw section.

Action

Ensure that the path specifies a raw section.


INOAAE0728 Unable to load data for CD databases
Explanation

This database is a CD database. Data load not possible.

Action

No action required.


INOAAE0731 Rename web server failed
Explanation

The web server could not be renamed, the operation failed.

Action

The reason why the web server could not be renamed is in the job log. Check it and retry.


INOAAE0733 Add web server failed
Explanation

The web server could not be added, the operation failed.

Action

The reason why the web server could not be added is in the job log. Check it and retry.


INOAAE0737 Delete web server failed
Explanation

The web server could not be deleted, the operation failed.

Action

The reason why the web server could not be deleted is in the job log. Check it and retry.


INOAAE0740 Modify web server failed
Explanation

The web server could not be modified, the operation failed.

Action

The reason why the web server could not be modified is in the job log. Check it and retry.


INOAAE0741 Domain 'name' does not exist
Explanation

Domain has not been defined.

Action

Please check the defined domains list in Tamino and create the domain if necessary.


INOAAE0744 parameter name: must not be a location on a raw section, is only allowed on DATA, INDEX, JOURNAL and RESERVED location
Explanation

A location on raw section is only allowed as DATA, INDEX, JOURNAL and RESERVED location.

Action

Use a location that is not located on a raw section.


INOAAE0745 All reserved locations are located on raw section(s), at least one location must not be located on a raw section
Explanation

At least one reserved location for a database must not be on a raw section.

Action

Use at lease one location not located on a raw section.


INOAAE0746 Location location name is of type type, this type is not allowed for location type
Explanation

Some location types are only allowed for special locations. For example locations on a tape are only allowed for backup locations.

Action

Use a location which is allowed for the current location type.


INOAAE0747 Not allowed to set a location of type 'type' as default backup location
Explanation

The default backup location cannot be in a location of type "raw".

Action

Use a location of a type that is allowed for a backup location.


INOAAE0749 This command is deprecated. Please use the new command "show acls".
Explanation

The command has been replaced by a new command.

Action

Please use the new command.


INOAAE0750 This command is deprecated. Please use the new command "show groups".
Explanation

The command is deprecated.

Action

Please use the new command.


INOAAE0753 Query internal configuration store key key failed
Explanation

An error occurred when querying the given internal configuration store key.

Action

Please contact your software supplier.


INOAAE0754 This command is deprecated. Please use the new command "show users".
Explanation

The command is deprecated.

Action

Please use the new command.


INOAAE0755 Access to internal configuration store value value key key failed
Explanation

An error occurred when getting the given internal configuration store key value.

Action

Please contact your software supplier.


INOAAE0761 parameter name: must be the logical name of an existing location
Explanation

The parameter must specify the short, "logical" name of a location (not its entire path), and the location must exist.

Action

Display the the "Locations" tree node in the System Management Hub (under the "Tamino" node) to display a list of existing locations or to add a new location.


INOAAE0762 parameter name: must contain only digits 0 to 9
Explanation

The value for this parameter must be an integer number with no fractional parts.

Action

Re-enter the parameter using only digits 0-9.


INOAAE0763 parameter name: must be "yes" or "no"
Explanation

This parameter must have either the value "yes" or "no", all lowercase characters.

Action

Re-enter either "yes" or "no" (without the double quotes).


INOAAE0764 parameter name: must only contain digits 0-9, comma, dot, "E" or "e" for exponentiation
Explanation

The value for this parameter must be a valid floating point number, or a number with an exponent.

Action

Re-enter he parameter value as floating point number, or with an exponent. Depending on the locale settings on the local computer, the decimal sign may be expected either as "," or as a ".".


INOAAE0766 Size for space type extent extend is missing and no default size available
Explanation

No default size could be obtained for this space type.

Action

A size must be specified, and it must be above the minimum value for this space type.


INOAAE0767 The size specified for space type extent extend is under the minimum (minimum size Mb)
Explanation

The given size for the extent is too small.

Action

A size of at least the given minimum must be specified.


INOAAE0768 At least one backup location must be in the filesystem if no tape is supplied as initial backup
Explanation

If no tape is supplied to create the database from (in the "Create From Backup" command) the initial backup is created at creation time as a file and requires a location that is in the file system. Before this message was issued, attempts were made to create it in one of the provided backup locations, in the default backup location and in the default location.

Action

Create a location in the file system using the "Add" command the System Management Hub browser interface, tree node Tamino/DB Locations and make it the default location (by clicking the new location and executing the "Set Default" command).


INOAAE0769 At least one backup location is required for the initial backup of the new database
Explanation

Specify one or more location where backups shall be created later on. This location is already required and used during the creation of the new database.

Action

Specify one or more writable, random accessible backup locations for the database to be created


INOAAE0774 Database version with compatibility level of CD database not installed or found
Explanation

A Tamino of the same compatibility level of CD database must be installed to use the CD database

Action

Install a database of the same compatibility level.


INOAAE0775 Database name contains invalid character "*" (asterisk)
Explanation

A database name cannot contain the "*" character.

Action

Remove the "*" from the database name.


INOAAE0776 This command is deprecated. Please use the new command "show users".
Explanation

This command is not supported as the user descriptions can be seen in the results of the new command.

Action

Please do not use this command and use the new one instead.


INOAAE0778 Database name contains invalid character "/" (slash)
Explanation

A database name cannot contain "/" character.

Action

Remove the "/" from database name.


INOAAE0779 Port address 'number' is invalid. Valid range is 0 - 65535.
Explanation

The specified port address is not valid.

Action

Specify a valid port address in the range 0 to 65535.


INOAAE0784 Database name contains invalid character "<" (less than)
Explanation

A database name cannot contain the "<" character.

Action

Remove the "<" from database name.


INOAAE0785 Database name contains invalid character ">" (greater than)
Explanation

A database name cannot contain the ">" character.

Action

Remove the ">" from database name


INOAAE0786 This command is deprecated. Please use the new command "show acesofacl".
Explanation

The command is deprecated.

Action

Please use the new command.


INOAAE0787 Domain parameters missing
Explanation

Some or all of the necessary parameters for the domain creation/modification are missing.

Action

Please ensure that all necessary domain parameters are defined.


INOAAE0788 Unrecognized domain parameters
Explanation

The domain parameters defined are not valid for the domain type being created/modified.

Action

Please ensure that the correct domain parameters for the domain type being created/modified are defined.


INOAAE0792 Namespace declarations required. Please check that all namespaces are defined.
Explanation

There are some namespace prefixes for which no namespace declarations have been defined.

Action

Please ensure namespace declarations exist for all namespace prefixes.


INOAAE0794 Internal error occurred
Explanation

Internal error code 41 occurred.

Action

Please contact your software supplier.


INOAAE0797 Domain 'name' already exists
Explanation

A domain with the same name exists.

Action

Please choose another name.


INOAAE0798 Failed to open input file file name for data load
Explanation

The file cannot be opened or does not exist.

Action

Check the input and start the operation again.


INOAAE0799 Parameter 'newname' or 'new_name' missing. The 'new_name' parameter is deprecated, please use the 'newname' parameter for the new name of the database.
Explanation

No parameter with the new name of the database was given.

Action

Provide the database name using the parameter 'newname'.


INOAAE0802 Could not connect to inodmn. Port number not found in internal configuration store, probably not installed.
Explanation

The Software AG EventLayer Service is not installed correctly.

Action

Try re-installing the System Management Hub. Check for a fix or an update from your software supplier.


INOAAE0803 Could not connect to inodmn, service not running
Explanation

The "Software AG EventLayer Service" is not running, database functions and commands are probably unaffected.

Action

Restart the service. If the problem persists, contact your software supplier for an update or fix.


INOAAE0807 Invalid parameter name 'name' specified.
Explanation

The parameter name specified is not valid since it contains one or more space characters.

Action

Specify a parameter name that does not contain space characters.


INOAAE0812 Web server IP address 'Address' is invalid
Explanation

The specified web server IP address is invalid.

Action

Specify a valid IP address. The valid range is 0 - 255.


INOAAE0817 No license for raw section support
Explanation

The use of raw sections requires an appropriate license option.

Action

Contact your software supplier for a license option to support raw sections.


INOAAE0818 No raw section support for the used platform
Explanation

There is no raw section support for the used platform.

Action

Do not use raw sections.


INOAAE0819 Raw section support internal error
Explanation

There was an internal error while processing a raw section.

Action

Please contact your software supplier.


INOAAE0820 Raw section initialization failed
Explanation

An error occurred while initializing a raw section.

Action

Check the raw section.


INOAAE0825 Master database must be restarted before a replication database can be set up
Explanation

A restart of the master database is necessary.

Action

Restart the master database and try to set up the replication database again.


INOAAE0826 Inconsistency detected while setting the database to replication type
Explanation

This database is not suitable to be set as the replication database of the specified master database. Perhaps the versions are not identical or this one was not created from the backup of the master. Also possible is that this database has its own updates after the creation.

Action

Use another database to replicate the master.


INOAAE0831 Only one location specified for parallel backup
Explanation

More than one location is required for parallel backup.

Action

Please specify more than one location for the parallel backup.


INOAAE0832 Renaming a replication database master is not allowed.
Explanation

Renaming a replication database master is not allowed, because the link between the master and replication databases would be lost.

Action

No action required.


INOAAE0834 Database is a replication database master database. Deleting the replication database master is not allowed. No replication databases can be updated from this master database if this database is deleted.
Explanation

Deleting this master database would mean that no replication databases could be updated from this master database. If you really want to delete this replication master database use the "force=yes" parameter for argbatch or check the "Force Delete of Replication Master Database" checkbox in the GUI.

Action

Use the "force=yes" parameter for argbatch or check the "Force Delete of Replication Master Database" checkbox in the GUI.


INOAAE0835 Data load for database database name failed
Explanation

Load of data failed with error.

Action

Check the other related messages for more information.


INOAAE0836 Unload data from database database name failed
Explanation

An error occurred while data was being unloaded from the database.

Action

Check for other messages related to this error for possible reasons.


INOAAE0837 Location path path is read only
Explanation

The location path specified is read only.

Action

Specify a location path with write access.


INOAAE0838 Server extension does not contain a function
Explanation

It was detected that no function has been defined for the server extension. Such a server extension is considered as invalid.

Action

Extend your server extension by at least one function.


INOAAE0841 Uninstall of server extension name aborted
Explanation

The uninstall operation for the server extension has not been completed due to functions that are used in some schema.

Action

Restart the uninstall operation with the parameter "force" set to "yes" (batch command).


INOAAE0842 Uninstall of server extension 'name' failed
Explanation

The uninstall operation failed.

Action

Check the job log to find the reason for the failure.


INOAAE0843 Please specify either parameter IP address or node
Explanation

The specification of the IP address or node is invalid.

Action

Please specify either the IP address or the node.


INOAAE0844 Unable to find the replication database name from the permission list
Explanation

The replication database name is not in the permission list.

Action

Check the parameter.


INOAAE0845 Please specify either parameter IP address or node
Explanation

Either the parameter IP address or node must be specified.

Action

Please specify either the parameter IP address or node.


INOAAE0846 Upgrade from this database to Vversion not possible
Explanation

This error occurs because the database cannot be upgraded directly to the target version.

Action

Upgrade to the next higher version and after that try a "set version" to the target version.


INOAAE0847 Named pipe path not allowed for the specified location type
Explanation

A named pipe is not allowed to set for the specified target location. Only the backup location type accepts named pipes.

Action

Specify another location for the target location.


INOAAE0849 Cannot open event log session
Explanation

Open event log session on argevsrv failed.

Action

Check that argevsrv is running.


INOAAE0850 parameter name: must be of type FileSystem or RAW Section
Explanation

Data, Index and Journal location must be of type FileSystem or RAW Section.

Action

Use a location of type FileSystem or RAW Section.


INOAAE0852 This command is deprecated. Please use the new command "inoload".
Explanation

This command is set to deprecated, use the new command instead.

Action

Use inoload to load or unload data in batch mode.


INOAAE0855 Output directory directory does not exist
Explanation

The output directory should exist.

Action

Create the output directory or check the permission if it already exists.


INOAAE0868 Stop request request number failed :error text
Explanation

Stop of a request failed.

Action

Check the error text for an explanation of why the operation failed.


INOAAE0870 Query current active requests failed : message
Explanation

A query of the current requests failed.

Action

Check the error message for more information.


INOAAF0002 Version 'version' of Tamino not found. Please use 'set version' command to change the version to the installed version.
Explanation

The specified Tamino version was not found.

Action

Use the "set version" command and change the version of the database.


INOAAF0007 Cannot create database: reason
Explanation

A database cannot be created with the parameters specified.

Action

Alter specified parameter value or provide missing parameter.


INOAAF0253 Error reading savepoints for database database name
Explanation

An error occurred when reading database savepoint entries in the internal configuration store.

Action

Please contact your software supplier.


INOAAF0254 Could not create XML document
Explanation

An error occurred when creating an XML document.

Action

Reboot and restart the system.


INOAAF0256 Open of event log failed
Explanation

An error occurred when creating an event session.

Action

Check the event demon.


INOAAF0262 Error reading database locations for savepoint 'savepoint'
Explanation

No database locations were found in the internal configuration store for the savepoint.

Action

Please contact your software supplier.


INOAAF0264 Duplicate parameter name parameter
Explanation

The parameter appears more than once in the parameter list, but only a single value is allowed.

Action

Check where the parameter given is repeated and issue the command again without it.


INOAAF0265 Job initialization failed
Explanation

The job log could not be initialized because of insufficient resources. This could be memory or SMP resources like locks or threads.

Action

Free resources and retry.


INOAAF0267 Rename database failed
Explanation

The database could not be renamed.

Action

The reason why the database could not renamed is in the job log. Check it and retry.


INOAAF0369 TSM@DLL *** FATAL ERROR NO ROLLBACK POSSIBLE (SESSION LOST) ***
Explanation

Tamino reported an invalid session ID.

Action

Shut down the database and restart it.


INOAAI0003 Modify journal space of database database name
Explanation

The size of the journal space is being modified.

Action

No action required.


INOAAI0005 Modify journal space successfully finished
Explanation

This message indicates that the "Modify journal space" function completed successfully.

Action

No action required.


INOAAI0006 Modification and reorganization of journal space in location location from old size MB to one journal space of new size MB
Explanation

The journal space size is being modified at the given location. If more the one journal space exists, the journal space is reorganized to one of the given size.

Action

No action required.


INOAAI0009 Add location name at path
Explanation

Start of the "add location" function.

Action

Information message, no action required.


INOAAI0010 Delete location name
Explanation

Start of the "delete location" function.

Action

Information message, no action required.


INOAAI0011 Moving location old location to new location
Explanation

Start of the "move location" function.

Action

Information message, no action required.


INOAAI0012 Rename location name to new name
Explanation

Start of the "rename location" function.

Action

Information message, no action required.


INOAAI0013 Set location name as default database location
Explanation

Start of the "set default location" function.

Action

Information message, no action required.


INOAAI0014 Set location name as default backup database location
Explanation

Start of the "set default backup location" function.

Action

Information message, no action required.


INOAAI0015 Modify default of database location category 'category'
Explanation

Start of the "modify default of database location category" function.

Action

Information message, no action required.


INOAAI0016 Database Version set to version
Explanation

The database was set to the specified version.

Action

Information message, no action required.


INOAAI0021 Unregistering database database name
Explanation

This is a job log identification message.

Action

No action required.


INOAAI0028 Confirmed all pending alerts
Explanation

All warnings, errors and fatal errors of the job records specified have been acknowledged.

Action

No action required.


INOAAI0033 New value of dynamic property 'name' is effective now
Explanation

The property value has been updated and is active from now on.

Action

No action required.


INOAAI0035 Database has been successfully unregistered
Explanation

This message indicates, that the "Unregister Database" function is completed.

Action

No action required.


INOAAI0037 Pending alerts of all jobs have been confirmed
Explanation

All warnings, errors and fatal errors have been confirmed. The job records may be deleted now.

Action

No action required.


INOAAI0048 Server extension command execution
Explanation

This is an informational message.

Action

No action required.


INOAAI0049 Command Name : name
Explanation

This message specifies the command name of a server extension.

Action

No action required.


INOAAI0050 Collection Name : name
Explanation

This message specifies the collection name of an XML document.

Action

No action required.


INOAAI0051 Master database set to master database
Explanation

The database named is the master database.

Action

No action required.


INOAAI0063 Tamino will close the current log space extent and open a new one when the current log space block has been filled up
Explanation

Tamino writes log information in blocks. When the currently used block has been filled up completely, Tamino will close the current log space extent and open a new one. As a consequence, you might encounter a minimal growth of the current log space before a new one is created.

Action

No action required.


INOAAI0148 The name 'location name' is not the name of an existing location; the default location is used instead
Explanation

An invalid location name was specified or extracted from a backup. It could be a valid location on the host where the backup was created.

Action

No action required. The location defined as default in the location management will be used.


INOAAI0152 No item selected for modification
Explanation

No item was selected to be modified.

Action

Select an item and retry.


INOAAI0160 Delete database space of database database name
Explanation

The database space with the highest extent is being deleted. The deletion will not proceed when the space is in use.

Action

No action required.


INOAAI0161 Delete database space successfully finished
Explanation

This message indicates that the "Delete database spaces" function completed successfully.

Action

No action required.


INOAAI0163 Expand database space of database database name
Explanation

The last database space is being expanded.

Action

No action required.


INOAAI0164 Expand database space successfully finished
Explanation

This message indicates that the "Expand database spaces" function completed successfully.

Action

No action required.


INOAAI0167 Deleting database space space number from location Location
Explanation

The specified database space is being deleted from the given location.

Action

No action required.


INOAAI0168 Expanding database space space number in location Location from old size MB to new size MB
Explanation

The specified database space is being expanded at the given location.

Action

No action required.


INOAAI0176 Restoring of database database name without further recovery successfully completed
Explanation

The specified database has been restored successfully. Changes that occurred later than the backup time were not reapplied.

Action

No action required.


INOAAI0211 Data load in collection collection name
Explanation

Data has been loaded into the named collection.

Action

No action required.


INOAAI0227 Data unload from collection collection name
Explanation

Data will be unloaded into the named collection.

Action

No action required.


INOAAI0237 count spaces successfully moved from old location to new location
Explanation

The specified number of spaces were moved from one location to another one.

Action

Information message, no action required.


INOAAI0248 Document path : path
Explanation

This message specifies the path name of an XML document.

Action

No action required.


INOAAI0249 Query string : text
Explanation

This message specifies the query string to retrieve XML documents.

Action

No action required.


INOAAI0250 Schema name : name
Explanation

This message specifies the schema name of a XML Document.

Action

No action required.


INOAAI0269 Execution of command 'name' successful
Explanation

A server extension command was successfully executed.

Action

No action required.


INOAAI0273 Location Count : location name
Explanation

This is an informational message for one default database location of the category.

Action

Information message, no action required.


INOAAI0275 No pending alerts found
Explanation

An attempt was made to confirm all pending alerts, but no job with pending alerts was found. Either there are no alerts in the display, or the alerts in the display have been confirmed meanwhile by someone else.

Action

No action required.


INOAAI0276 When all pending alerts are confirmed, the "Pending Alerts" folder is cleared. Each individual job is still in the "Running Jobs" or in the "Completed Jobs" folder until it is deleted by automatic cleanup; up to that point, the warning, error and alert messages are still visible in the single job view.
Explanation

No job or message is really removed when alerts are confirmed; they are just moved away from the Alerts folder.

Action

No action required


INOAAI0277 When a job record is deleted, it is removed from the job log and its disk file is deleted. Jobs that are not completed (i.e. stopped or still running) and jobs that have unconfirmed alert messages are not deleted and remain in their respective folders.
Explanation

Only finished jobs with no pending alerts are deleted.

Action

No action required


INOAAI0280 Object Identification : text
Explanation

The given text provides the object identification of the server extension.

Action

No action required.


INOAAI0286 Execution type: type
Explanation

The specified type is the selected server extension execution type.

Action

No action required.


INOAAI0288 Backing up all server extensions for database 'name'
Explanation

All server extensions in the specified database are being backed up.

Action

No action required.


INOAAI0289 Backup of all server extensions successful
Explanation

All server extensions have been backed up successfully.

Action

No action required.


INOAAI0290 Restoring server extension for database 'name'
Explanation

A server extension of the specified database is being restored.

Action

No action required.


INOAAI0291 Restore of server extension 'name' successful
Explanation

The specified server extension has been restored successfully.

Action

No action required.


INOAAI0292 Restoring all server extensions for database 'name'
Explanation

All server extensions of the specified database are being restored.

Action

No action required.


INOAAI0293 Restore of all server extensions successful
Explanation

All server extensions have been restored successfully.

Action

No action required.


INOAAI0299 Storing binary file 'path'
Explanation

A binary file is being stored in the database.

Action

No action required.


INOAAI0300 Restoring binary file 'path'
Explanation

A binary file is being restored from the database.

Action

No action required.


INOAAI0301 Removing binary file 'path'
Explanation

A binary file is being removed from the database.

Action

No action required.


INOAAI0303 Command log switched mode buffers buffers
Explanation

This is a result message for a batch command.

Action

No action required.


INOAAI0308 Update of settings successful : name
Explanation

The update of the given settings parameter value was successful.

Action

No action necessary.


INOAAI0316 Backing up server extension for database 'name'
Explanation

A server extension in the specified database is being backed up.

Action

No action required.


INOAAI0317 Backup of server extension 'name' successful
Explanation

The specified server extension has been backed up successfully.

Action

No action required.


INOAAI0318 Deleting document : name
Explanation

The XML document will be deleted.

Action

No action necessary.


INOAAI0319 No mapped document : name
Explanation

No XML document is mapped to the server extension.

Action

No action necessary.


INOAAI0320 Trace server extensions in database 'name'
Explanation

The server extension trace mode is changed in the specified database.

Action

No action required.


INOAAI0321 Trace switched on successfully
Explanation

The server extension trace is switched on.

Action

No action required.


INOAAI0322 Trace switched off successfully
Explanation

The server extension trace is switched off.

Action

No action required.


INOAAI0323 Store server extensions in database 'name'
Explanation

The storing of server extension files is changed to the specified database.

Action

No action required.


INOAAI0324 Store server extension files switched on successfully
Explanation

The storing of server extension files is switched on.

Action

No action required.


INOAAI0325 Store server extension files switched off successfully
Explanation

The storing of server extension files is switched off.

Action

No action required.


INOAAI0326 Analyze object for a new server extension
Explanation

The object for a new server extension will be analyzed.

Action

No action required.


INOAAI0327 Object File : path
Explanation

This specifies the object file for the new server extension.

Action

No action required.


INOAAI0328 Analysis of new server extension object successful
Explanation

The analysis of the object for the new server extension was successful.

Action

No action required.


INOAAI0329 Remove server extension object
Explanation

The object of a new server extension will be removed.

Action

No action required.


INOAAI0330 Select function for a new server extension
Explanation

The function for a new server extension will be selected.

Action

No action required.


INOAAI0331 Select function for a new server extension successful
Explanation

The function for a new server extension was successfully selected.

Action

No action required.


INOAAI0332 Display trace state successful
Explanation

The server extension trace state is displayed successfully.

Action

No action required.


INOAAI0333 Create Database from Backup
Explanation

Button Create Database from Backup

Action

none


INOAAI0357 Access Control List 'name' created
Explanation

A new access control list has been created. Details are generally provided in other messages.

Action

No action required.


INOAAI0358 User group 'name' created
Explanation

A new user group has been created.

Action

No action required.


INOAAI0360 User 'name' created
Explanation

A new user has been created. Details are generally provided in other messages.

Action

No action required.


INOAAI0364 Access control list 'name' modified
Explanation

The current ACL has been modified.

Action

No action required.


INOAAI0365 User group 'name' modified
Explanation

The user group has been modified.

Action

No action required.


INOAAI0366 User 'name' modified
Explanation

The user has been modified.

Action

No action required.


INOAAI0368 Access control element 'name' added to the access control list
Explanation

An ACE has been added successfully to an ACL.

Action

No action required.


INOAAI0374 Access control list 'name' deleted
Explanation

The access control list has been deleted.

Action

No action required.


INOAAI0375 User 'name' deleted
Explanation

The user has been deleted.

Action

No action required.


INOAAI0376 User group 'name' deleted
Explanation

The user group has been deleted.

Action

No action required.


INOAAI0406 Shutdown of all active databases completed
Explanation

All active databases are about to shut down, or they are already inactive.

Action

No action required.


INOAAI0407 All autostart databases checked
Explanation

All databases with autostart parameter set have been started.

Action

No action required.


INOAAI0410 operation name of operation done
Explanation

This message provides information about operation progress.

Action

No action required


INOAAI0424 New value : text
Explanation

This describes a new value for a Java public or private classpath.

Action

No action required.


INOAAI0425 Starting autostart databases of version version
Explanation

Databases with the autostart parameter set to 'yes' are being started.

Action

No action required.


INOAAI0426 Stopping all active databases of version version
Explanation

Active databases are being stopped

Action

No action required.


INOAAI0429 Confirming all alerts
Explanation

Fatal error, error and warning messages are being confirmed. Once all alerts are confirmed, a job will be scheduled for cleanup (will be removed later), or it can be delete explicitly as a single job or along with all completed jobs.

Action

No action required.


INOAAI0431 Deleting all completed jobs
Explanation

All jobs without unconfirmed alerts are being deleted.

Action

No action required.


INOAAI0432 All job records of completed jobs successfully deleted by user (except jobs with pending alerts)
Explanation

Deleted job records will not appear in the job monitor list any more; the corresponding files have been deleted on disk.

Action

No action required.


INOAAI0445 Setting version for database 'database name'
Explanation

Set the version of a specific database.

Action

Data must be unloaded and loaded into a new database manually.


INOAAI0446 No property has been modified. All properties already set to the given values.
Explanation

A property will be changed when the new property value is different from the value stored in the internal configuration store.

Action

No action required.


INOAAI0448 'parameter' has been changed from 'old value' to 'new value'
Explanation

A database property was changed successfully by the "modify property" command.

Action

No action required.


INOAAI0451 Adding database space for database database name
Explanation

This message indicates the beginning of the execution of the "Add database spaces" function.

Action

No action required.


INOAAI0452 Add database space successfully finished
Explanation

This message indicates that the "Add database spaces" function completed successfully.

Action

No action required.


INOAAI0454 Moving database space for database database name
Explanation

This message indicates the beginning of the execution of the "Move database spaces" function.

Action

No action required.


INOAAI0455 Move database space successfully finished
Explanation

This message indicates that the "Move database spaces" function completed successfully.

Action

No action required.


INOAAI0457 Creating database database name
Explanation

This message indicates the beginning of the execution of the "Create Database" function.

Action

No action required.


INOAAI0458 Create database successfully finished
Explanation

This message indicates that the database was created successfully.

Action

No action required.


INOAAI0460 Deleting database database name
Explanation

This message indicates the beginning of the execution of the "Delete Database" function.

Action

No action required.


INOAAI0461 Database has been successfully deleted
Explanation

This message indicates that the "Delete Database" function completed successfully.

Action

No action required.


INOAAE0463 The database information is available in ONLINE mode only
Explanation

The information can only determined when the database is started.

Action

Start the database and call the information function again.


INOAAI0465 Start of database database name successful
Explanation

This message indicates that the specified database has been started successfully.

Action

No action required.


INOAAI0467 Stop of database database name successful
Explanation

This message indicates that the specified database has been stopped successfully.

Action

No action required.


INOAAI0468 Backup of database database name
Explanation

This message indicates that a backup of the specified database is being created.

Action

No action required.


INOAAI0469 Restore database database name using backup 'backup date' with recovery
Explanation

This message indicates the beginning of the execution of a database restore function with a database recovery based on the log spaces.

Action

No action required.


INOAAI0470 Restore database database name using backup 'backup date' without recovery
Explanation

This message indicates the beginning of the execution of a database restore function without a database recovery based on the log spaces.

Action

No action required.


INOAAI0471 Backup of database database name successfully completed
Explanation

This message indicates that the specified database has been backed up successfully.

Action

No action required.


INOAAI0476 Restoring and recovering of database database name successfully completed
Explanation

The specified database has been restored and recovered successfully.

Action

No action required.


INOAAI0477 Moving database space space number from location old location to new location
Explanation

A database space is being moved from one location to another.

Action

No action required.


INOAAI0479 Adding size MB database space to location new location
Explanation

The specified database space is being added to the given location.

Action

No action required.


INOAAI0484 Uninstalling all server extensions in database 'name'
Explanation

All server extensions in a database are being uninstalled from the specified database and the file system. If a restore is being performed the server extensions will be recovered from the backup database.

Action

No action required.


INOAAI0490 Modify database properties successfully finished
Explanation

Database properties have been modified successfully.

Action

No action required.


INOAAI0492 Modify properties for database database name
Explanation

Database properties are being modified.

Action

No action required.


INOAAI0493 Restore database database name using backup 'backup date' with partial recovery
Explanation

A database restore function with partial recovery has been started.

Action

No action required.


INOAAI0494 Checking and repairing database database name
Explanation

A function to check and repair the database has been started.

Action

No action required.


INOAAI0495 Check and repair of database database name finished successfully
Explanation

The check and repair function was successfully applied to the specified database, i.e. the recreation of the indices was successful.

Action

No action required.


INOAAI0497 help
Explanation

This is a standard information message to show the server version in space and property commands.

Action

No action required.


INOAAI0501 Uninstall of all server extensions successful
Explanation

All server extensions in a database have been uninstalled successfully. This is an informational message.

Action

No action required.


INOAAI0502 Registering Java class 'path'
Explanation

The installation count for the Java class is added to the internal configuration. This is an informational message.

Action

No action required.


INOAAI0505 Function name: 'name'
Explanation

This is the name of a server extension function. This is an informational message.

Action

No action required.


INOAAI0506 External name: 'name'
Explanation

This is the external name of a server extension function. This is an informational message.

Action

No action required.


INOAAI0511 Parameter 'parameter' not valid
Explanation

The specified parameter is not valid for the current command.

Action

Check the spelling of the parameter. If the spelling is correct, check whether the parameter is valid in the current context.


INOAAI0514 message
Explanation

This is an informational message about a server extension document that has been returned from the Tamino server.

Action

No action required.


INOAAI0515 Listing server extensions in database 'name'
Explanation

A list of all installed server extensions for the specified database is being generated.

Action

No action required.


INOAAI0516 Installing server extension in database 'name'
Explanation

A new server extension is being installed in the specified database.

Action

No action required.


INOAAI0517 Package file: path
Explanation

The specified path is the pathname of the packed server extension file.

Action

No action required.


INOAAI0518 Execution mode: mode
Explanation

The specified mode is the selected server extension execution mode.

Action

No action required.


INOAAI0519 Installation of server extension 'name' successful
Explanation

The specified server extension was installed successfully.

Action

No action required.


INOAAI0520 Uninstalling server extension from database 'name'
Explanation

A server extension is being uninstalled from the specified database.

Action

No action required.


INOAAI0521 Server extension name: 'name'
Explanation

This message specifies the name of a server extension.

Action

No action required.


INOAAI0522 Uninstall of server extension 'name' successful
Explanation

The specified server extension has been uninstalled successfully.

Action

No action required.


INOAAI0523 Modifying server extension in database 'name'
Explanation

A server extension in the specified database is being modified.

Action

No action required.


INOAAI0524 Modification of server extension 'name' successful
Explanation

The specified server extension has been modified successfully.

Action

No action required.


INOAAI0525 Deleting help URL 'path'
Explanation

The specified help file for a server extension is being deleted.

Action

No action required.


INOAAI0526 Executing command 'call'
Explanation

The specified operating system command is being executed.

Action

No action required.


INOAAI0527 De-registering server extension DLL 'path'
Explanation

The specified server extension DLL file is being de-registered.

Action

No action required.


INOAAI0528 Deleting server extension DLL 'path'
Explanation

The specified server extension DLL file is being deleted.

Action

No action required.


INOAAI0529 Deselect function of a new server extension
Explanation

A selected function for a new server extension is being deselected. This is an informational message.

Action

No action required.


INOAAI0530 Extracting entry 'name'
Explanation

An entry is being extracted from a packed file.

Action

No action required.


INOAAI0531 Inserting document 'path'
Explanation

The URL of a help file for a server extension is being inserted into the server extension's installation document.

Action

No action required.


INOAAI0532 Registering DLL 'path'
Explanation

A server extension DLL file is being registered.

Action

No action required.


INOAAI0533 DLL 'path' already registered
Explanation

The specified server extension DLL file is already registered.

Action

No action required.


INOAAI0535 Deleting file 'name'
Explanation

The specified server extension installation file is being deleted.

Action

No action required.


INOAAI0536 Deleting directory 'path'
Explanation

The specified server extension installation directory is being deleted.

Action

No action required.


INOAAI0537 Showing server extension attributes in database 'name'
Explanation

The attributes of a server extension in the specified database are being listed.

Action

No action required.


INOAAI0538 Setting access rights for server extension in database 'name'
Explanation

The access rights of a server extension are being set in the specified database.

Action

No action required.


INOAAI0543 Stopping database database name in normal mode
Explanation

This message indicates that the specified database is being stopped in normal mode.

Action

No action required.


INOAAI0544 Stopping database database name in abort mode
Explanation

This message indicates that the specified database is being stopped in abort mode.

Action

No action required.


INOAAI0545 Stopping database database name in rollback mode
Explanation

This message indicates that the specified database is being stopped in rollback mode.

Action

No action required.


INOAAI0568 Unexpected messages received
Explanation

This message is the header for subsequent messages.

Action

No action required.


INOAAI0569 Edit details for a new server extension
Explanation

Details for a new server extension will be edited.

Action

No action required.


INOAAI0570 Description: text
Explanation

This is a short description of the new server extension.

Action

No action required.


INOAAI0571 Author name: name
Explanation

This is the name of the new server extension author.

Action

No action required.


INOAAI0572 Help file: name
Explanation

This is the name of a help file for the new server extension.

Action

No action required.


INOAAI0573 Editing of new server extension details successful
Explanation

The editing of the new server extension details was successful.

Action

No action required.


INOAAI0574 Starting database database name
Explanation

A Tamino database is being started.

Action

No action required.


INOAAI0577 Unloading document 'path'
Explanation

The server extension object information document is being unloaded.

Action

No action required.


INOAAI0578 Edit details for a new server extension function
Explanation

Details for a new server extension function will be edited.

Action

No action required.


INOAAI0579 Function type: text
Explanation

This message displays the type of a server extension function.

Action

No action required.


INOAAI0580 Editing of new server extension function details successful
Explanation

The editing of the new server extension function details was successful.

Action

No action required.


INOAAI0581 Loading document 'path'
Explanation

A server extension analyzer document is being loaded.

Action

No action required.


INOAAI0582 Start Database
Explanation

This is a command for the Tamino agent dbagent.

Action

No action required.


INOAAI0583 Stop Database
Explanation

This is a command for the Tamino agent dbagent.

Action

No action required.


INOAAI0584 Delete Database
Explanation

This is a command for the Tamino agent dbagent.

Action

No action required.


INOAAI0587 Check and Repair
Explanation

This is a command for the Tamino agent dbagent.

Action

No action required.


INOAAI0589 Information
Explanation

This is a command for the Tamino agent dbagent.

Action

No action required.


INOAAI0591 Database Spaces
Explanation

This is a command for the Tamino agent dbagent.

Action

No action required.


INOAAI0592 Properties
Explanation

This is a command for the Tamino agent dbagent.

Action

No action required.


INOAAI0598 Register CD Database
Explanation

This is a command button for the Tamino agent dblist.

Action

No action required.


INOAAI0599 Prepare for CD
Explanation

This is a command for the Tamino agent dblist.

Action

No action required.


INOAAI0600 Unregister CD Database
Explanation

This is a command button for the Tamino agent dbagent.

Action

No action required.


INOAAI0601 Create a new server extension package
Explanation

This is an informational message.

Action

No action required.


INOAAI0602 Package path: path
Explanation

This is the pathname of the server extension package.

Action

No action required.


INOAAI0603 Creation of package 'name' successful
Explanation

A server extension package was created successfully.

Action

No action required.


INOAAI0604 Port range successfully changed
Explanation

The port range was successfully changed.

Action

none


INOAAI0607 inodmp return error
Explanation

This message shows a return value of inodmp.

Action

No action required.


INOAAI0612 Deselection of function 'name' successful
Explanation

The server extension function was successfully deselected.

Action

No action required.


INOAAI0613 Modify parameter of server extension function
Explanation

The parameter name and XML type of a selected server extension function will be modified.

Action

Insert the corresponding values.


INOAAI0614 Parameter name: name
Explanation

This specifies the name of the parameter being modified.

Action

No action required.


INOAAI0615 Modified name: name
Explanation

This specifies the modified name of the parameter.

Action

No action required.


INOAAI0616 XML type: type
Explanation

This specifies the modified XML type of the parameter.

Action

No action required.


INOAAI0617 Modification of parameter 'name' successful
Explanation

A server extension function parameter was successfully modified.

Action

No action required.


INOAAI0618 Preparation of CD database successful
Explanation

This is an informational message.

Action

No action required.


INOAAI0625 Renaming database database name to database name
Explanation

The database is being renamed.

Action

No action required.


INOAAI0626 Database successfully renamed
Explanation

The database was renamed successfully.

Action

No action required.


INOAAI0627 Server extension class 'name'
Explanation

This message specifies the Java class name of a server extension.

Action

No action required.


INOAAI0629 database successfully registered
Explanation

A database has been successfully registered.

Action

No action required.


INOAAI0630 Registering CD database database name
Explanation

The CD database is being registered.

Action

No action required.


INOAAI0631 Location name at path successfully added
Explanation

The location was successfully added.

Action

No action required.


INOAAI0632 Location name successfully deleted
Explanation

The location was successfully deleted.

Action

No action required.


INOAAI0633 Location name successfully renamed to new name
Explanation

The location was successfully renamed.

Action

No action required.


INOAAI0634 Location name successfully set as default database location
Explanation

The location was successfully set as the default database location.

Action

No action required.


INOAAI0635 Location name successfully set as default backup database location
Explanation

The location was successfully set as the default backup location.

Action

No action required.


INOAAI0636 Default of database location category 'category' successfully modified
Explanation

The default database location category was successfully modified.

Action

No action required.


INOAAI0642 Stopping XML session
Explanation

The XML session is being stopped.

Action

No action required.


INOAAI0649 Setting global parameters for external backup method 'method' of database database name
Explanation

Global parameters for external backup method are being set.

Action

No action required, information message.


INOAAI0650 Global parameters for external backup method 'method' of database database name successfully set
Explanation

The global parameters were successfully set.

Action

No action required, information message.


INOAAI0652 Setting configuration parameters for external backup method 'method' of database database name
Explanation

The configuration parameters for the external backup method are being set.

Action

No action required, information message.


INOAAI0654 Configuration parameters for external backup method 'method' of database database name successfully set
Explanation

The configuration parameters were successfully set.

Action

No action required, information message.


INOAAI0655 Deleting configuration 'configuration' of method 'method' of database database name
Explanation

The "delete configuration" function was started.

Action

No action required, information message.


INOAAI0657 Configuration 'configuration' of method 'method' of database database name successfully deleted
Explanation

The configuration parameters were successfully deleted.

Action

No action required, information message.


INOAAI0661 Replication database name name added into the permission list
Explanation

This is a status report that the replication database name has been added into the permission list.

Action

No action required.


INOAAI0663 Replication database name name removed from the permission list
Explanation

The replication database name has been removed from the permission list.

Action

No action required, this is an information message.


INOAAI0664 Database database set to replication type
Explanation

The database is set to the type "replication database".

Action

No action required, this is an information message.


INOAAI0666 Replication database database has been reset to normal type
Explanation

The replication database was reset so that it is a normal database.

Action

No action required, this is an information message.


INOAAI0670 Private Classpath: path
Explanation

The displayed path is the server extension private Java classpath.

Action

No action required.


INOAAI0671 type Classpath: path
Explanation

The specified operation type is performed with the server extension private Java classpath.

Action

No action required.


INOAAI0673 Keep files from backup date and time
Explanation

This indicates that the backup files will be saved.

Action

No action required, information message.


INOAAI0674 Move backup space to "destination"
Explanation

The backup space is being moved moved to new location.

Action

No action required, information message.


INOAAI0682 Switching log space for database database name
Explanation

A switch of the log space is initiated.

Action

No action required.


INOAAI0687 Nothing has changed: mode
Explanation

The specified server extension attribute did not change.

Action

No action required.


INOAAI0688 Attribute: mode
Explanation

This specifies a new attribute of the parameter.

Action

No action required.


INOAAI0689 Default value : text
Explanation

This specifies the default value of the parameter.

Action

No action required.


INOAAI0690 Adding backup method 'method' for database database name
Explanation

An external backup method of the database is being added.

Action

No action required, information message.


INOAAI0692 Backup method 'method' successfully added for database database name
Explanation

The backup method has been successfully added.

Action

No action required, information message.


INOAAI0693 Deleting method 'method' of database database name
Explanation

An external backup method of the database is being deleted.

Action

No action required, information message.


INOAAI0695 Method 'method' of database database name successfully deleted
Explanation

The backup method has been successfully deleted.

Action

No action required, information message.


INOAAI0697 Deleting backup 'backup date' of database database name
Explanation

The backup of the database is being deleted.

Action

Information message, no action required.


INOAAI0698 Deletion of backup 'backup date' of database database name successfully completed
Explanation

The specified database backup has been deleted successfully.

Action

Information message, no action required.


INOAAW0700 Updating existing server extension 'name'
Explanation

A previous version of the server extension is already installed in the database and will be updated.

Action

No action required.


INOAAI0701 Remove permitted replication database name name from master database database name
Explanation

This is a title for the messages for removing a database name from the permission list.

Action

No action required.


INOAAI0702 Add permitted replication database name
Explanation

This is a title for adding database name into the permission list.

Action

No action required.


INOAAI0704 Set type to normal database
Explanation

This is a title for setting the database type to a normal one.

Action

No action required.


INOAAI0705 Create replication database list
Explanation

This is a title for create replication database list.

Action

No action required.


INOAAI0706 Retrieve replication database information
Explanation

This is a title for retrieving the information of databases.

Action

No action required.


INOAAE0709 Passwords not matched
Explanation

The passwords entered do not match.

Action

Please ensure the passwords match.


INOAAI0711 Domain 'name' created
Explanation

The domain has been created.

Action

No action required.


INOAAI0713 Domain 'name' modified
Explanation

The domain has been modified.

Action

No action required.


INOAAI0715 Domain 'name' deleted
Explanation

The domain has been deleted.

Action

No action required.


INOAAI0718 Creating database database name from backup dated timestamp
Explanation

A new database is created with the content of a given backup. The log spaces belonging to the backup are not recovered.

Action

No action required.


INOAAI0721 Web server assignments changed.
Explanation

The web server assignments for this database have changed.

Action

No action required.


INOAAI0722 Setting port ranges for Tamino databases
Explanation

The static and dynamic port ranges are being set.

Action

No action required.


INOAAI0726 Port ranges successfully changed
Explanation

The port ranges were successfully changed.

Action

No action required.


INOAAI0729 Renaming web server 'name' to 'new name'
Explanation

The web server is being renamed.

Action

No action required.


INOAAI0730 Web server successfully renamed
Explanation

The web server was successfully renamed.

Action

No action required.


INOAAI0732 Web server successfully added.
Explanation

The web server was added successfully.

Action

No action required.


INOAAI0734 Adding web server 'new name'
Explanation

The web server is being added.

Action

No action required.


INOAAI0735 Deleting web server 'name'
Explanation

The web server is being deleted.

Action

No action required.


INOAAI0736 Web server successfully deleted
Explanation

The web server was deleted successfully.

Action

No action required.


INOAAI0738 Modifying web server 'name'. New IP address: 'address', new node: 'node', new port: 'port'.
Explanation

The web server is being modified.

Action

No action required.


INOAAI0739 Web server successfully modified
Explanation

The web server was modified successfully.

Action

No action required.


INOAAI0751 Preparing CD database database name
Explanation

A CD database is being prepared.

Action

No action required.


INOAAI0770 Could not create database, cleaning up now
Explanation

The "Create Database" or "Create Database From Backup" command has failed. Files, internal configuration store entries and XTS entries made during this process are deleted.

Action

No action required.


INOAAI0771 Location location selected for initial backup
Explanation

The initial backup could not be created in the first backup location specified. It has been created in the location indicated in the message text instead.

Action

No action required.


INOAAI0781 The command requires an active database
Explanation

An attempt was made to execute a command that requires an active database, but the the database is inactive.

Action

The database must be started before the command can be executed.


INOAAI0782 The command requires an inactive database
Explanation

An attempt was made to execute a command but the database is active and the command requires an inactive database.

Action

The database must be stopped before the command can be executed.


INOAAI0789 Web server assignments changed. Please restart all databases which have this web server assigned to make your changes effective.
Explanation

The web server assignments for this database have changed.

Action

Please restart all databases which have this web server assigned to make your changes effective.


INOAAI0795 Set type to replication database with simultaneous query
Explanation

The flag for simultaneous query for replication is set to 'enabled'.

Action

No action required.


INOAAI0796 Set type to replication database without simultaneous query
Explanation

The flag to allow simultaneous query for replication is disabled.

Action

No action required.


INOAAI0821 Initialize raw section
Explanation

This is an event log message while the raw section is being initialized.

Action

No action required.


INOAAI0822 Raw section successfully initialized
Explanation

The raw section has been successfully initialized.

Action

No action required.


INOAAI0827 Set static min port minimum
Explanation

The static minimum port is being set. All Tamino database static ports must be greater than or equal to this value.

Action

No action required.


INOAAI0828 Set static max port maximum
Explanation

The static maximum port is being set. All Tamino database static ports must be lower than or equal to this value.

Action

No action required.


INOAAI0829 Set dynamic min port minimum
Explanation

The dynamic minimum port is being set. Tamino databases use the port range for dynamically allocated ports. This port range should not be used by any other software.

Action

No action required.


INOAAI0830 Set dynamic max port maximum
Explanation

The dynamic maximum port is being set. Tamino databases use the port range for dynamically allocated ports. This port range should not be used by any other software.

Action

No action required.


INOAAI0840 Function function is used in collection name, schema name, doc type type
Explanation

The server extension to be uninstalled contains a function that is still used in the given context.

Action

Typically no action is required but be aware that in the case of a forced uninstall the corresponding functions cannot be executed any longer.


INOAAI0848 Restart parameter ignored, because only dynamic properties changed
Explanation

A restart parameter was given, but a restart is only useful if a static property is changed.

Action

No action required.


INOAAI0865 Moving space space number of database database name from old location to new location
Explanation

The database space of the named database is being moved from one location to another location.

Action

No action required.


INOAAI0866 Stop current request(s)
Explanation

Stop a current running request.

Action

No action required.


INOAAI0867 Request request number successfully stopped
Explanation

A request has been successfully stopped.

Action

No action required.


INOAAI0869 No current active requests found
Explanation

No requests are running on the XML Server.

Action

No action required.


INOAAW0071 Higher server extension versions exist : name
Explanation

In other databases, higher versions of this server extension exist.

Action

Back up the server extension.


INOAAW0150 Backup spaces are copied because one or more spaces could still be part of an existing backup generation
Explanation

To protect integrity of backup generations, spaces with the Tamino backup filename extension "1B0" are always copied because they could be part of a backup generation on the local host, or another remote host.

Action

Make sure that the selected backup spaces are not used in a backup generation by a local database or elsewhere, and then change their filename extension to something different from "1B0".


INOAAW0166 Parameter 'parameter' unknown
Explanation

The specified database parameter name is not known by the Tamino server.

Action

Check the spelling of the parameter. If the spelling is correct, check whether the parameter is valid in the current context.


INOAAW0206 Required space type size could not be obtained from the backup, using minimum sizes where not specified otherwise
Explanation

Minimum sizes will be used if not specified otherwise but the new database might refuse to start with these settings.

Action

Specify the effective spaces of the saved database if creating with the minimum sizes does not succeed.


INOAAW0271 Cannot move space of database database, because the database is online
Explanation

The database of the database space to move is in an active state.

Action

Stop the database.


INOAAW0411 Show progress aborted
Explanation

The progress information process is aborted because no more progress is determined, but operation is not finished.

Action

No action required.


INOAAW0422 An error has occurred when user user attempted to remove the records of all completed jobs without pending alerts from the job log
Explanation

One or more job records may remain in the given job log after the attempt to delete all due records.

Action

Check if the service is running. If the problem persists, job records can be deleted "physically" by deleting the files with the extensions "0G0" and "0F0" in the directory were job records are stored (try the "log" directory in the Tamino or System Management Hub root directory) and restarting the service. This however will also delete records with pending alerts and records of active commands and should only be done as a last resort.


INOAAW0433 File 'path' not deleted
Explanation

The server extension file could not be deleted.

Action

No action necessary.


INOAAW0434 File 'path' not found
Explanation

The specified file could not be found.

Action

No action necessary.


INOAAW0435 Directory 'path' not deleted
Explanation

The directory is in use. Therefore it cannot be deleted.

Action

Wait until the directory is not in use, then retry the operation.


INOAAW0436 Directory 'path' not found
Explanation

The specified directory was not found.

Action

Check the permissions of your file system.


INOAAW0440 Automatic assign of ports for the database failed, please assign the ports manually
Explanation

The database is not usable until the ports are assigned manually.

Action

Assign the ports for the database manually.


INOAAW0640 After restarting the Tamino server the server extension will be updated correctly
Explanation

The Tamino server crashed. The server extension will be usable after restart.

Action

Restart the Tamino server to use this server extension .


INOAAW0676 Please store the tape(s) from backup date and time in a safe place!
Explanation

Tapes cannot be saved, the user must store them in a safe place.

Action

Keep the backup in a safe place.


INOAAW0677 Please store the files from external backup date and time in a safe place!
Explanation

External backups cannot be saved, the user must store them in a safe place.

Action

Keep the external backup in a safe place.


INOAAW0800 Disabling autostart for database database name
Explanation

The parameter "autostart" of the database has been set to "false".

Action

No action required.


INOAAW0804 No property changed, property name and value is missing
Explanation

There is no property name in the command.

Action

Supply the name of the property and the new value (propertyname=value) at the end of the batch command.


INOAAW0815 Parameter 'name' is ignored for server extensions with execution type 'type'
Explanation

The parameter cannot be used for server extensions of the given execution type.

Action

No action required.


INOAAW0833 Force ignore replication database master status is set.
Explanation

Normally it is not allowed to delete a replication database master, so force ignore replication master status is set. The database will be removed.

Action

No action required.


INOAAW0839 Server extension name is used in schema
Explanation

In some node of a schema a function of the server extension name is used.

Action

See the following messages for detailed information.


INOAAW0851 No backups with user data found, please don't use option "Keep Backups"
Explanation

No backups with user data found, please don't use option "Keep Backups".

Action

Do not use the option "Keep Backups".


INOAAW0853 This command is deprecated. Please use the new command "inoload".
Explanation

This command is set to the deprecated state and will be disabled in the next version

Action

Use the new command inoload instead of this command.


INOAAW0854 COM server extension registration/deregistration suppressed
Explanation

When packaging the COM server extension, the option to suppress the registration/deregistration commands has been used.

Action

It is the installer's responsibility to make sure the COM objects are correctly registered/deregistered using the methods provided by the underlying infrastructure.


INOAAW0871 Can't connect to XTS directory server rc = error number
Explanation

Can't connect to XTS directory server. This server is necessary for Tamino databases.

Action

Check the XTS directory server.


INOAAE0020 Modify Email notification properties failed
Explanation

The modification of Email notification properties failed.

Action

Look at the detailed error message and action.


INOAAE0024 Change License file failed
Explanation

Change license file failed.

Action

Check the license file.


INOAAE0026 The parallel option is not supported for incremental backups
Explanation

Options "parallel" and "incremental" are mutually exclusive.

Action

Select only one of the options.


INOAAI0000 Change License file
Explanation

Change license file.

Action

No action required.


INOAAI0008 Modify properties of Email notification
Explanation

Email notification properties are being modified.

Action

No action required.


INOAAI0017 Modify Email notification properties successfully finished
Explanation

Email notification properties have been modified successfully.

Action

No action required.


INOAAI0023 New license file sucessfully applied.
Explanation

The license file was successfully applied.

Action

No action required.


INOAAI0025 Please log in again to the web application in order to use the new product license!
Explanation

The new functionality is available after you log in again.

Action

Log in again and restart your web applications.


INOCVE8065 Collection collection contains non-migrated indexes
Explanation

The upgrade was rejected because there are non-migrated indexes in Tamino 4.1.4.

Action

Please migrate the indexes. Refer to the migration documentation for details.


INOCVE8067 Collection collection contains doctypes that are not namespace clean
Explanation

The upgrade was rejected because at least one doctype in the database is not namespace clean.

Action

Please perform a namespace cleanup. Refer to the migration documentation for details.


INOCVE8069 Conversion of data mapping to version version has failed with response response
Explanation

An error occurred during the conversion of data mapping for standard index and collations.

Action

Please contact your software supplier.


INOCVE8071 The count of existing user collections has failed with response response
Explanation

The query to count existing user collections has failed.

Action

Please contact your software supplier.


INOCVE8073 number installed COM server extensions found, conversion not allowed
Explanation

It is not possible to convert a Tamino database to this version as COM server extensions are installed.

Action

Contact your software supplier for help with switching versions.


INOCVE8074 Counting existing COM server extensions has failed with response response
Explanation

The query to count existing COM server extensions has failed.

Action

Contact your software supplier for help with switching versions.


INOCVE8075 Request to create indexes for doctype doctype in collection collection is pending
Explanation

A request to create indexes is pending.

Action

Please correct the current status using the admin-command ino:repairIndex with option CONTINUE or DROP.


INOCVE8077 The schema check for existing user collections has failed
Explanation

The test define of existing user collection during "set version" has failed.

Action

Please contact your software supplier.


INOCVE8078 The check for server extension installation has failed
Explanation

The query to check whether a server extension is installed has failed.

Action

Please contact your software supplier.


INOCVE8070 number TSD2 user collections exist
Explanation

TSD2 user collections exist and must be migrated to TSD3.

Action

Please use the migration tool to migrate the TSD2 user collections.


INOCVW8066 Schema "schema" in collection "collection" contains unknown attributes
Explanation

The given schema in the given collection contains unknown attributes.

Action

Remove additional attributes before next schema update.


INOCVW8076 The schema check for schema schema in collection collection has failed with response response
Explanation

The test of defining all existing user collections during "set version" has failed.

Action

Please check the schema using the following admin-command ino:CheckSchema(collection-name, schema-name). Correct the schema and update it in Tamino.


INOSXW6702 Warning: Settings for compiler 'compiler' already exist and will be overwritten
Explanation

Compiler and linker flags already exist for the compiler specified in this warning. Choosing 'OK' will overwrite these settings.

Action

Choose 'OK' to overwrite these settings or 'Cancel' to stop this action.


INOSXW6703 The path 'path' will be added to the list of executable files of Visual Studio
Explanation

Some libraries residing in Tamino system directories are needed to build a server extension. These directories must be listed in the "Executable files" section of your Visual Studio configuration. If not yet present, sxwizard will add these directories automatically.

Action

Click on OK to accept these changes to your Visual Studio configuration. If you click on Cancel, no changes will be made and sxwizard will be stopped.


INOSXW6721 Project will be moved from platform 'name' to 'name'
Explanation

This (SXS Direct) project has been created on platform1. It is now opened on a different platform platform2, and a new make file will be created such that it can be compiled on this new platform.

Action

Click OK to generate a new make file, or click cancel if you do not want to have a new make file created. However, this project probably cannot be compiled on this platform.


INOSXW6722 Project will be moved from an older Tamino version to platform 'platform'
Explanation

This (SXS Direct) project has been created by an older version of Tamino. It is now opened by a newer Tamino version on a different platform. A new make file will be created such that it can be compiled in this version and on this new platform.

Action

Click OK to generate a new make file, or click cancel if you do not want to have a new make file created. However, this project probably cannot be compiled in this Tamino version.


INOSXW6724 Unable to start JVM with user options 'options'. Starting with default options instead.
Explanation

Conflicting or incorrect user options were specified for the JVM, so the JVM could not start. The JVM will be started with the default options.

Action

Correct the user options specified for the JVM and restart the server.


INOSXW6727 The server extension generated a warning.
Explanation

The server extension has invoked the warning XML callback. This will insert a warning into the Tamino response.

Action

The warning message is for informational purposes.


INOSXW6728 Execution failed: Actual operating system command being executed
Explanation

The specified operating system command failed.

Action

Check the SXS installation values for faults.


INOSXW7002 Existing server extension project at 'path' will be overwritten
Explanation

A server extension project already exists in the given directory. It will be overwritten if you select "Finish".

Action

Press "OK" to overwrite this project or select another directory.


INOSXW7003 Java initialization failed. Reason: 'error number', 'error text'.
Explanation

Tamino was not able to create a Java virtual machine. Java based server extensions will not work.

Action

Make the Java virtual machine available to Tamino and start the Tamino server again or switch the server property X-Tension Java Usage to 'NO'.


INOSXW7004 Java thread initialization failed. Reason: 'error number', 'error text'.
Explanation

An XML worker thread could not be attached to the Java virtual machine. Java based server extensions will not work.

Action

Fix the problem of Java initialization and start the Tamino server again.


INOSXW7005 Initialization of COM library failed. Reason: 'error number', 'error text'.
Explanation

COM based server extensions will not work.

Action

Make the COM library available to the Tamino server, then start it again.


INOSXW7007 No license for Tamino X-Tension
Explanation

A special license must be bought to use the Tamino X-Tension feature.

Action

Buy a license for Tamino X-Tension.


INOSXW7008 Tamino X-Tension not available
Explanation

On this platform the Tamino X-Tension feature is not available.

Action

No action required.


INOSXW7011 This will remove all previously selected files from your package list
Explanation

For a server extension package, either one or more class files or ONE jar file can be used. This warning shows up in one of the following cases: 1) A jar file was selected and a class file will be added to the class file list: The jar file will be removed from the list. 2) One or more class files or another jar file were selected, and a jar file will be added: All recently selected files will be removed.

Action

Choose "OK" to confirm or "Cancel" to cancel the current selection


INOSXW7012 Main Class File for server extension missing
Explanation

For a server extension package, either one or more class files or ONE jar file can be used. This warning shows up when none of the selected class files contains the main class of the server extension.

Action

Add another class file that contains the main class of the server extension.


INOSXW7013 Server extension might not run without these class(es)
Explanation

In the Packaging Dialogue of the X-Tension Builder, one of the selected class files is about to be removed. Without this class file the installation of this server extension will be incomplete.

Action

Check if this class file is really unnecessary for the current server extension.


INOSXW7031 Directory 'name' does not exist and will be created
Explanation

This directory does not exist and will be created.

Action

Select "OK" to create this directory, select "Cancel" to cancel project creation.


INOSXW7135 The given class contains no server extension function
Explanation

The given class does not contain any method that can be used as a server extension function.

Action

Enter some methods using the direct server extension development tools.


INOSXW7139 No valid JVM, install valid JVM or switch X-Tension Java Usage to 'NO'
Explanation

Error detected when loading a JVM for current Tamino version

Action

Check if JVM is installed, if a valid JVM Version is installed or switch X-Tension Java Usage to 'NO'.


INOSXW7159 Value will be set to empty string
Explanation

A default value or configuration parameter (Init Function) may be set to empty string if data type is charstring.

Action

Please check if in this special case this effect is intended.


INOSXE6704 Invalid character 'character' in name for compiler settings
Explanation

Names for compiler settings must start with a letter and may be followed by letters or digits.

Action

Use a name that obeys this rule.


INOSXE6705 Settings for default parameter must not be changed
Explanation

The name 'default' is reserved for the compiler settings defined by the Tamino installation.

Action

Use a name other than 'default' to save these compiler settings.


INOSXE6706 No configuration parameters found for compiler 'compiler'
Explanation

The current compiler for Direct X-Tension projects is currently set to the compiler indicated; however, one or all of its configuration parameter files have been deleted.

Action

Use the default compiler as your current compiler; check your Tamino installation.


INOSXE6707 X-Tension: COM initialization failed
Explanation

During X-Tension initialization the initialization of the COM library failed. No COM-based extension functions are available during this server session.

Action

If COM-based server extension functions are required, fix the COM problem and start the Tamino server again.


INOSXE6709 Invalid usage entry: 'value'
Explanation

The Usage entry found in file 'Install.xml' could not be recognized.

Action

Check the documentation for valid values.


INOSXE6710 Function 'function' not usable as 'usage'
Explanation

This function cannot be used as the function type indicated. The function's parameter count or parameter datatypes do not correspond to the specified function type.

Action

Please check the 'Usage' entry in file 'Install.xml' as well as the parameter specification of the current function. See the documentation for the parameters required for the given Usage.

It is strongly recommended to use the X-Tension development tools to define new X-Tension functions.


INOSXE6711 Value missing for Init Function 'function'
Explanation

The X-Tension function indicated has been declared as Init Function. However, values are missing for one or more of its parameters.

Action

Use the X-Tension tools to create the X-Tension function and be careful editing the file Install.xml.


INOSXE6712 The server extension crashed or threw an unknown exception
Explanation

Either the server extension has crashed or it threw an exception that could not be caught by the Tamino Server.

Action

Please contact the vendor of the server extension.


INOSXE6713 Extension tried to open message box. Message: 'message'.
Explanation

It is not allowed to display message boxes in a server extension. This terminates the current server extension function.

Action

Please check the server extension code carefully. Maybe the C/C++ runtime system tried to open an assertion box because of programming errors in the server extension.


INOSXE6714 Value is not of the selected data type 'type'
Explanation

The value entered cannot be converted to the data type selected in the 'Add Param' box.

Action

Please check the value entered and the data type selected in the 'Add Param' box. See the documentation of Tamino X-Tension for more details on allowed values.


INOSXE6715 Extension function 'function': Value of parameter 'parameter' is not of selected data type type
Explanation

The value entered cannot be converted to the data type specified for this parameter.

Action

Please check the value entered and the data type specified for this parameter. See the documentation of Tamino X-Tension for more details on allowed values.

Use the Tamino X-Tension tools to specify parameter values!


INOSXE6716 Unexpected error during callback function 'function'
Explanation

An unexpected error occurred during a call of a callback function. Probably it has been called with one or more incorrect parameters.

Action

Check the documentation and your server extension code for the correct use of this callback function.


INOSXE6717 Server extension function not found
Explanation

The desired function name was not found in the SXS repository. Maybe the function name is incorrect, or the function is not installed or was deinstalled.

Action

Check and correct the function name or server extension installation.


INOSXE6725 Callback not allowed in init function
Explanation

An SxsSetProperty callback is not allowed from a server extension init function.

Action

Remove the SxsSetProperty callback from your server extension init function and retry the operation.


INOSXE7000 Java server extension must have a package name
Explanation

The package name for a Java server extension must not be empty.

Action

Define a package name, e.g. "package com.softwareag.mysxs".


INOSXE7001 File name 'file.sxp' may not be changed
Explanation

Only the directory may be selected; the file name must remain unchanged.

Action

Select a directory.


INOSXE7006 XML callback failed. Transaction was rolled back.
Explanation

No more information.

Action

Try with a modified XML request.


INOSXE7009 Tamino X-Tension not available
Explanation

It is not possible to call a Tamino server extension because either X-Tension is not licensed or the X-Tension feature is not available on this platform.

Action

If possible, buy a license for Tamino X-Tension.


INOSXE7010 Project must be rebuilt before packing. Reason: 'reason'.
Explanation

The project must be rebuilt. See 'reason' for more information.

Action

Call Build / Build <project name> in the Developer Studio before packing.


INOSXE7014 Main class file cannot be removed
Explanation

In the Packaging Dialogue of the X-Tension Builder, the class file is about to be removed that contains the main class of the current server extension.

Action

Do not remove this class file from the list or select a jar file containing this class.


INOSXE7015 Callback not allowed in event function
Explanation

From Tamino server event functions, XML and ODBC callback are not allowed.

Action

Remove the callback call from your server extension code.


INOSXE7016 Illegal database command in callback
Explanation

A database command that is not allowed in callbacks was called in a callback.

Action

Remove the database command from the callback and try again.


INOSXE7017 Tamino server error when calling callback
Explanation

An error occurred in the Tamino server when processing the callback, perhaps an XML or query syntax error.

Action

Method SXJBase.SXSGetInoMsgNo ( ) gives the error code of the Tamino server.


INOSXE7018 Not enough memory for callback
Explanation

The Tamino server could not allocate enough memory to process the callback.

Action

Try to repeat your query when the Tamino server is less loaded.


INOSXE7019 SQL error when calling ODBC callback
Explanation

An SQL error occurred while processing an ODBC callback, perhaps due to an SQL syntax error.

Action

Method SXJBase.SXSGetSQLMsgNo ( ) gives the SQL error code.


INOSXE7020 Illegal handle type for ODBC callback
Explanation

The ODBC callback methods SxsSQLAllocHandle and SxsSQLFreeHandle are only allowed for statement handles of type SQL_HANDLE_STMT.

Action

We recommend that you use the constant SXJBase.SQL_HANDLE_STMT as the parameter handle type.


INOSXE7021 Commit and rollback are not allowed in callbacks
Explanation

You must not use the database commands "commit" or "rollback" in your server extensions.

Action

Remove these commands from the server extension and try again.


INOSXE7022 Result buffer for callback not initialized
Explanation

Result buffers for callbacks must not be null, but should be initialized with an empty string.

Action

Ensure that all result buffers are initialized.


INOSXE7023 Function 'name' failed, because XML callback failed with error 'number'
Explanation

An XML callback failed while trying to perform a write operation. To avoid inconsistencies, the extension function must return with an error.

Action

Check the error caused by the XML callback and fix the problem that caused it to fail.


INOSXE7024 COM error when calling callback
Explanation

A COM error occurred during a callback.

Action

Consult your COM documentation.


INOSXE7025 Another server extension deinstallation is running
Explanation

Only one server extension can be deinstalled at any given time.

Action

Wait until the other deinstallation procedure has finished.


INOSXE7026 Deinstallation timed out. The server extension is in use.
Explanation

A server extension cannot be deinstalled as long as an instance of it is in use. The deinstallation procedure has timed out.

Action

Try it later. If there is a very long running instance of the server extension, try to stop it.


INOSXE7027 The function cannot be executed. The server extension is being deinstalled.
Explanation

This function belongs to a server extension that is just being deinstalled.

Action

The function cannot not be called again. If you need to, contact the database administrator.


INOSXE7032 Cannot create directory 'name'
Explanation

This directory cannot be created. Maybe the disk drive is unavailable or write protected.

Action

Check the given path and your disk drive.


INOSXE7034 Server extension 'source' threw exception 'error number', 'error text'
Explanation

The server extension threw an exception. The number and message of the exception are delivered.

Action

See the documentation of the server extension in question for more information.


INOSXE7040 Extension function name too long: 'name'
Explanation

The complete extension function name, consisting of the extension's name plus the function name plus a dot, must not exceed the length of 80 characters.

Action

Select a shorter name.


INOSXE7041 Wrong character in field: 'character'
Explanation

Some special characters (ampersand, "less than", "greater than") are not allowed in comment fields for a server extension. This affects the "Short description" fields and the "Author" field.

Action

Avoid these characters.


INOSXE7045 X-Tension Trace failed. Transaction was rolled back.
Explanation

An internal server error occurred while X-Tension Trace information was written to the Tamino server.

Action

Deactivate X-Tension Trace


INOSXE7046 XML Callback failed in user session. Transaction must be rolled back.
Explanation

A writing XML call from a server extension failed. The current transaction should be rolled back for consistency reasons.

Action

Perform a rollback request.


INOSXE7047 X-Tension Trace failed in user session. Transaction must be rolled back.
Explanation

An internal server error occurred. The current transaction should be rolled back for consistency reasons.

Action

Deactivate X-Tension Trace


INOSXE7048 Error starting help browser. Reason: 'reason'.
Explanation

The currently configured help browser could not be started. See "reason" for more details.

Action

Use the function "Help/Configure Help Browser" to change your current help browser.


INOSXE7049 'Program name' execution failed: rc = error
Explanation

The external program 'Program name' was successfully started but it returned with error.

Action

See the context of this error message for more information.


INOSXE7051 COM error 'error number' occurred: 'error text'
Explanation

A COM error occurred. The COM error number of type HRESULT is delivered.

Action

Consult the COM documentation for more information.


INOSXE7052 COM error 'error number' calling 'dllname': 'error text'
Explanation

A COM error occurred. The COM error code of type HRESULT and the name of the Tamino server extension DLL which was called is delivered.

Action

Consult the COM documentation for more information.


INOSXE7053 Error 'error number' calling data map: 'error text'
Explanation

An error occurred when the Tamino server extension part of the data map was accessed. The error number and message received from the Tamino data map is delivered.

Action

Look up the delivered error number and see the action described there.


INOSXE7054 X-Tension system function cannot be deleted
Explanation

An attempt was made to delete a function which is needed for the X-Tension administration.

Action

No action required.


INOSXE7055 The server extension threw exception 'error text'.
Explanation

The server extension threw an exception. The message and occasionally the number of the exception are delivered.

Action

See the documentation of the server extension in question for more information.


INOSXE7056 X-Tension caller: Not enough memory
Explanation

There was not enough memory for execution of the server extension function.

Action

Close some applications and try again.


INOSXE7057 X-Tension caller: internal error
Explanation

Internal errors occurred within the X-Tension administration structure.

Action

Please contact your software supplier.


INOSXE7058 X-Tension caller: got no spinlock. Reason: 'number'.
Explanation

An error occurred within the thread synchronization. A server extension could not be locked. The return value received from the thread administration is delivered.

Action

Please contact your software supplier.


INOSXE7059 X-Tension caller: could not get data map information
Explanation

The X-Tension caller was unable to get any data map information.

Action

Please contact your software supplier.


INOSXE7060 Mapping function 'name': Wrong number of parameters implemented. Expected: 'number'.
Explanation

A Tamino server extension mapping function does not support the number of parameters needed for this function type.

Action

Install a correctly implemented server extension.


INOSXE7061 Extension function 'name': Wrong type of parameter 'number' implemented
Explanation

A mapping function does not support the correct parameter types.

Action

Compare the parameter type for this type of extension function as described in the manual with the parameter type supported by the extension function (found using Tamino Manager). Install a correctly implemented extension function.


INOSXE7062 X-Tension caller: initialization failed
Explanation

The X-Tension caller was not initialized when the Tamino server was started. It is impossible to call any extension function, maybe because server extension libraries could not be loaded.

Action

Check your Tamino installation.


INOSXE7063 X-Tension caller: 'number' server event calls failed
Explanation

A server event call to some server extensions failed. The number of failures is delivered.

Action

Please contact your software supplier.


INOSXE7064 Unexpected end of file encountered before end of source
Explanation

During the parsing of the X-Tension installation file, IDL file or one of the server extension source files, an unexpected end of file was found.

Action

Check the syntax of the file(s).


INOSXE7065 Syntax error. Token: 'Token'.
Explanation

An unspecified error was encountered during parsing near or at the place specified by 'Token'.

Action

Check the syntax of the X-Tension installation file.


INOSXE7066 Unbalanced tag / end tag: 'name' /' name'
Explanation

In the X-Tension installation file, the names of begin-tag and end-tag are different.

Action

Check the syntax of the X-Tension installation file.


INOSXE7067 Tag 'name' not found
Explanation

The specified mandatory tag was not found in the X-Tension installation file.

Action

Check the syntax of the X-Tension installation file.


INOSXE7068 Tag 'name' is not a value
Explanation

A simple value was expected for the specified tag, but a node has been found.

Action

Check the syntax of the X-Tension installation file.


INOSXE7069 Tag 'name' is not a node
Explanation

A node was expected for the specified tag, but a simple value has been found.

Action

Check the syntax of the X-Tension installation file.


INOSXE7070 Duplicate name: 'name'
Explanation

The specified tag name was found twice in the X-Tension installation file.

Action

Check the syntax of the X-Tension installation file.


INOSXE7071 Error 'character' expected
Explanation

The specified character was expected but not found in the X-Tension installation file or one of the server extension source files.

Action

Check the syntax of the X-Tension installation file and the server extension source files.


INOSXE7072 Error 'character' expected, eof found
Explanation

The specified character was expected, but an end of file was found in the X-Tension installation file or one of the server extension source files.

Action

Check the syntax of the X-Tension installation file and the server extension source files.


INOSXE7073 IDL file 'segment name' is corrupt
Explanation

A syntax error was found in the IDL file for the definition of the server extension interface at or near the specified keyword.

Action

Check the syntax of the IDL file.


INOSXE7074 'Function' not defined in interface
Explanation

The specified function has been defined in the X-Tension installation file but it had not been entered into the IDL file for the server extension interface.

Action

Remove the function definition from the X-Tension installation file and use the X-Tension Developer Studio add-in to define a new one.


INOSXE7075 Return type must be HRESULT, not 'type'
Explanation

A COM server extension must always return HRESULT.

Action

Use the [retval] attribute for the last parameter as a return value of the server extension function.


INOSXE7076 Method 'method': Different parameter names: 'text' / 'text'
Explanation

The parameter name of the indicated server extension function in the X-Tension installation file is different from that defined in the IDL file.

Action

Check the implementation of the server extension function; use the X-Tension Developer Studio add-in to define a server extension function.


INOSXE7077 Too many parameters: 'Function'
Explanation

The specified server extension function has been implemented with more parameters than are defined in the X-Tension installation file.

Action

Check the implementation of the server extension function; use the X-Tension Developer Studio add-in to define a server extension function.


INOSXE7078 Cannot map parameter type
Explanation

A parameter type is used in the COM interface that cannot be used for server extension function parameters.

Action

Use the X-Tension Developer Studio add-in to define a server extension function.


INOSXE7079 Server extension implementation file could not be found
Explanation

The X-Tension Developer Studio add-in could not find the file with the implementation of the class for the server extension.

Action

Use the X-Tension development tool to create a server extension.


INOSXE7080 Unknown XML data type: 'type'
Explanation

The specification of the XML data type for a server extension function parameter is wrong. See the documentation for allowed data types.

Action

Use the X-Tension Developer Studio add-in to define a new server extension function.


INOSXE7081 Unknown programming language data type: 'type'
Explanation

The function implementation uses a data type for one of its parameters that is not supported when using this function as a server extension function. See the documentation for the allowed data types in this programming language

Action

Use the X-Tension development tools to define a server extension function.


INOSXE7082 Unknown execution mode: 'mode'
Explanation

The specified server extension execution mode is wrong. Allowed modes are: COM-INPROC, COM-LOCAL.

Action

Use the Tamino Manager to change this mode.


INOSXE7083 Wrong numeric value: 'value'
Explanation

The value was expected to be numeric but the given value is not numeric.

Action

Enter a numeric value here.


INOSXE7084 Wrong parameter position
Explanation

The parameter position in the X-Tension installation file must start at 1.

Action

Check the parameter position values. Use X-Tension Developer Studio add-in to define a new server extension function.


INOSXE7085 Cannot open file 'name'
Explanation

The specified file could not be opened.

Action

Check if this file really exists, or if it is locked by another process.


INOSXE7086 Wrong version format: 'string'
Explanation

The server extension version is supposed to be of the form major.minor

Action

Check the server extension version.


INOSXE7087 Event function 'function' not found
Explanation

An event function has been specified in the SXS-EVENT-FUNCTION tag of the X-Tension installation file, but it could not be found in an SXS-FUNCTION tag.

Action

Delete the event function specification tag and use the X-Tension Developer Studio add-in to specify a new one.


INOSXE7088 Wrong document type for X-Tension administration: 'type'
Explanation

The document type (second level tag) of the X-Tension administration file is wrong. Allowed types are: SXS-INSTALL, SXS-DELETE, SXS-SHOW, SXS-RETURN.

Action

For a server extension installation, only SXS-INSTALL is valid.


INOSXE7089 Missing XML attribute 'attribute' for SXS-SHOW
Explanation

No attribute is given for the X-Tension administration type tag SXS-SHOW.

Action

One of the attributes list, object, function, permission, document must be given for the SXS-SHOW tag.


INOSXE7090 Wrong XML attribute: 'attribute'
Explanation

A wrong attribute is given for the X-Tension administration type tag SXS-SHOW.

Action

One of the attributes list, object, function, permission, document must be given for the SXS-SHOW tag.


INOSXE7091 Wrong parameter attribute: 'attribute'
Explanation

A wrong parameter attribute has been specified in the X-Tension installation file. Allowed attributes are: input, output, inout, retval.

Action

Use the X-Tension Developer Studio add-in to define a new server extension function.


INOSXE7092 No current project
Explanation

There is no project open in Developer Studio. The X-Tension add-in will not work.

Action

Open a server extension project first.


INOSXE7093 This is not a C/C++ project
Explanation

The X-Tension add-in will not work for Java or Visual Basic projects.

Action

Open a C/C++ project.


INOSXE7094 This is not an X-Tension project
Explanation

The current project has not been created by an X-Tension development tool.

Action

Use the X-Tension development tool to create a server extension.


INOSXE7095 File 'name' is read-only
Explanation

The specified file is read-only. Therefore, the X-Tension Developer Studio add-in cannot add the specifications for the new server extension function to it.

Action

Change the ReadOnly parameter of the specified file.


INOSXE7096 System error: 'error text'
Explanation

An operating system error occurred in the X-Tension Developer Studio add-in.

Action

Check the operating system documentation for further details.


INOSXE7099 Cannot write to file 'name'
Explanation

The file has been opened, but a write operation failed. Possibly the disk is full.

Action

Check your hard disk space.


INOSXE7100 Wrong package file: 'name'
Explanation

The file specified is not an output file of the X-Tension Developer Studio add-in package function.

Action

Only use package files created by the X-Tension Developer Studio add-in.


INOSXE7101 Could not get XML session status. Server extension function rolled back at request end.
Explanation

The X-Tension caller could not determine whether there was a regular or an anonymous XML session. So the Tamino server event 'rollback' was sent to all server extensions.

Action

No action required.


INOSXE7102 Initialization of server extensions: server events not activated
Explanation

The Tamino server events could not be activated when the Tamino server was started. Server extensions are not initialized and will not work.

Action

Restart the Tamino server. If this does not give the desired result, please contact your software supplier.


INOSXE7103 Developer Studio automation error 'error number' (error text)
Explanation

The add-in caused an error when executing a Developer Studio command.

Action

Consult the Developer Studio documentation for further information.


INOSXE7104 Method 'method' could not be found in file 'object file'
Explanation

The method indicated is not defined in the current server extension object file (Java class file or DLL/Shared Object), or another severe error occurred when accessing the server extension object file.

Action

Check the server extension project for the desired method.

Use the X-Tension development tools for developing server extensions!


INOSXE7105 Project must be rebuilt before packing: 'file' is newer
Explanation

One of the project sources is newer than the resulting server extension package.

Action

Call Build / Build <project name> in the Developer Studio before packing.


INOSXE7106 One or more input fields are empty