Optimize 10.7 | webMethods Optimize Documentation | Administering webMethods Optimize | For System Administrators | Configuring Optimize | Securing Optimize Engines with SSL | Updating the Configuration Settings in the Central Configurator
 
Updating the Configuration Settings in the Central Configurator
At this point the certificates and SSL setup should be complete for each of the Optimize components. These include the Analytic Engine, Infrastructure Data Collector and the Web Service Data Collector. Because the certificate setup and protocol change required manual updates, the components are not in sync with the Central Configurator. This next step simply updates the protocol information for each of the Optimize components and deploys out an "official" copy of the EndpointRegistry.xml configuration file.
*To update the Configuration Settings in the Central Configurator:
1. In My webMethods, navigate the following path: Applications > Administration > System-Wide > Environments > Define Environments.
2. Open the configuration for the applicable environment.
3. Select the Map Endpoints tab and change the protocol field under "Incoming Connections" for each of the Optimize components "Configuration Agent" WS endpoint to "https".
4. Click Save and then Finish.
You will be returned to the main Define Environments page. This page should show that the "Deployed" status has been updated to indicate that the configuration has been changed.
5. Click the green arrow on the right under "Actions" to navigate to the Deploy Configuration Files page.
6. Click the Deploy Updates button to push the configuration changes out to all of the Optimize components.
You should see that the "System Endpoint Registry" configuration has been deployed to each of the Optimize components.