Optimize 10.5 | webMethods Optimize Documentation | Using webMethods Optimize | Monitoring System Component and Business Process Performance | Viewing the Overall Status of Process Instances | About Resubmitting Process Instances and Process Steps | Resubmitting Processes from a Step and Optionally Editing Pipeline Information
 
Resubmitting Processes from a Step and Optionally Editing Pipeline Information
*To resubmit a step in a process instance and optionally edit pipeline information
1. In My webMethods: Navigate > Applications > Monitoring > Business > Process Instances.
2. Search for the process instance you want to resubmit.
3. In the search results, locate the process instance that you want to resubmit and click Instance Detail icon Detail.
Note:
If your process instance has failed in multiple places, it may be necessary to resubmit multiple steps to get the instance running correctly. If this is the case, repeat the resubmit procedures for each step that requires resubmission.
4. On the Step Summary window of the Process Instance Detail page, locate the step that you want to resubmit and click Step Detail icon Detail.
Note:
At this point, you can view or save the step pipeline data in XML format for additional analysis. Click Save Pipeline To File, and then click Open to view the file or click Save to save the file, then click OK.
5. To edit the input pipeline for a step on the Process Step Detail page:
a. In the Step Information window, click Edit Pipeline.
Important:
After you update the pipeline, the changes you make are available only while you are still on the Process Step Detail page. If you leave this page, the changes you make are not saved. If you want to edit the pipeline before resubmitting, you must make your edits and then immediately resubmit the process step.
Note:
The pipeline for the original iteration of the step is left unchanged. The updated pipeline is logged with the new iteration of the step.
b. On the Edit Step page, for each field value you want to change:
a. Click the hyperlinked field value that you want to change. If the value of a field is not displayed with an active hyperlink, you cannot change that field value.
b. Specify a new value for the field.
c. Click OK.
d. After you modify all the fields you want to change, click Save. Monitor returns to the Process Step Detail page.
6. Click Resubmit.