Optimize 10.11 | webMethods Optimize Documentation | Administering webMethods Optimize | Built-In Services | pub.optimize.monitoring:createNewConnection | Input Parameters
 
Input Parameters
The following table describes the input parameters.
brokerURL
String Defines an additional JMS server to which information will be sent.
The Software AG Universal Messaging URL format is as follows:
nsp://{host}:{port}
The Broker (deprecated) URL format is as follows:
broker://{host}:{port}/{brokerName}/analysis
useSSL
String Indicates that the connection to the JMS server requires a secure connection.
useEncryption
String Indicates that the connection to the JMS server requires encryption.
KeyStoreFile
String Type the absolute path to the private key file that is located on a server accessible by the component. This field is required only if you enable SSL.
KeyStoreType
StringType the appropriate string to specify the Key Store Type (PKCS12 or JKS). This field is required only if you enable SSL.
distinguishName
String Type the name of the appropriate certificate identifier. This field is required only if you enable SSL.
trustStoreFile
String Type the absolute path to the CA certificate file on a server location accessible by Analytic Engine. This field is required only if you enable SSL.
trustStoreType
String Click the drop down to select the Trust Store Type (PKCS12 or JKS). This field is required only if you enable SSL.
password
String Type the pass phrase to access the specified Key and Trust Stores. This field is required only if you enable SSL.