Message Class XCO - X-COM Console Messages

This page explains the Console Messages, which have the format

XCOnnnns

where XCO is the error code
nnnn is the message number, and
s indicates the severity of the error:
E: error; function cannot be performed
I: information
W: warning; potential problem exists

Overview of Messages

XCO0003E | XCO0005E | XCO0007E | XCO0008E | XCO0009I | XCO0010W | XCO0011E | XCO0012E | XCO0013E | XCO0014E | XCO0015E | XCO0016I | XCO0019E | XCO0020I | XCO0021W | XCO0022I | XCO0023I | XCO0024I | XCO0025I | XCO0026E | XCO0027E | XCO0028I | XCO0029I | XCO0030I | XCO0031I | XCO0032I | XCO0033I | XCO0034I | XCO0035I | XCO0036I | XCO0037I | XCO0039I | XCO0041E | XCO0043E | XCO0044E | XCO0045E | XCO0046E | XCO0047E | XCO0048E | XCO0050E | XCO0051W | XCO0052W | XCO0053W | XCO0054W | XCO0055I | XCO0057I | XCO0061W | XCO0062W | XCO0063E | XCO0077I | XCO0078E | XCO0080E | XCO0081E | XCO0082I | XCO0083W | XCO0084W | XCO0085W | XCO0086I | XCO0087E | XCO0088I | XCO0089E | XCO0091I | XCO0095E | XCO2001E | XCO2002E | XCO2003E | XCO2004E | XCO2005E | XCO2006E | XCO2007E | XCO2008E | XCO2009E | XCO2010E | XCO2011E | XCO2012E | XCO2013E | XCO2014E | XCO2015E

XCO0003E ERROR DURING READ OF STARTUP PARMS.
Explanation

Error occurred while attempting to open the file designated by the PARMS DD.

Action

Correct and verify that the PARMS DD is pointing to the file containing the startup parameters. Restart Broker.


XCO0005E LOAD FOR MODULE :1: FAILED - ABEND.
Explanation

The loading of module :1: failed.

Action

Check and verify whether the module :1: is in the library concatenation. If not, add the appropriate library containing the module :1:. Restart Broker.


XCO0007E WRONG X-COM PARAMETER :1:.
Explanation

The X-COM parameter :1: is incorrect or not specified.

Action

Add or correct the value for the parameter :1:. Restart Broker.


XCO0008E ADAMPM - WRONG VERSION FOUND.
Explanation

The verification of ADAMPM failed.

Action

Ensure that the correct version of ADAMPM is contained in the library concatenation. Restart Broker.


XCO0009I X-COM node is initialized.
Explanation

X-COM has initialized the target and is ready for work.

Action

No action required.


XCO0010W Wrong ECB found.
Explanation

The type of returned event indicator is not valid and will be ignored. X-COM nucleus continues to wait for requests.

Action

Contact Software AG Support.


XCO0011E X-COM data error.
Explanation

The routine to check X-COM data has detected an inconsistency. X-COM nucleus terminates abnormally.

Action

Contact Software AG Support.


XCO0012E USER RET (R15) error.
Explanation

One of the routines called by X-COM nucleus has returned an error. X-COM nucleus terminates abnormally.

Action

Contact Software AG Support.


XCO0013E Delete ECB error.
Explanation

An ECB cannot be removed from the wait list. X-COM nucleus terminates abnormally.

Action

Contact Software AG Support.


XCO0014E No ANSWER entry point.
Explanation

The entry point for the reply handler could not be found. X-COM nucleus cannot process any user replies and terminates abnormally.

Action

Contact Software AG Support.


XCO0015E APPL ECB throw away.
Explanation

The X-COM nucleus was posted to send the reply to the user but could find the related X-COM data. X-COM nucleus ignores the post and continues to wait for requests.

Action

No action required.


XCO0016I Operator typed in: :1:.
Explanation

Message confirming operator input.

Action

No action required.


XCO0019E X-COM parm list wrong.
Explanation

The request or reply handler has returned inconsistent data. X-COM nucleus terminates abnormally.

Action

Contact Software AG Support.


XCO0020I X-COM stopped
Explanation

X-COM nucleus is calling the termination handler for shutdown

Action

No action required


XCO0021W This X-COM is no longer active
Explanation

X-COM nucleus has successfully executed the termination handler

Action

No action required


XCO0022I X-COM cancel will proceed
Explanation

The operator command XCANCEL to cancel Entire System Server was entered

Action

No action required


XCO0023I X-COM halted
Explanation

The operator command XHALT was entered. This means that no more calls are possible, but the Entire System Server task is still available and can be restarted with the XSTART command

Action

No action required


XCO0024I X-COM started
Explanation

The operator command XSTART was entered. This means that calls are now processed again

Action

No action required


XCO0025I X-COM end will proceed
Explanation

The operator command XEND to end Entire System Server was entered

Action

No action required


XCO0026E APPL stop error
Explanation

The shutdown handler has returned an error

Action

Contact Software AG Support.


XCO0027E Timer error
Explanation

Setup of timer services has failed. X-COM nucleus terminates abnormally

Action

Contact Software AG Support.


XCO0028I Number of active users = :1:
Explanation

Output of command XUSER reporting the current number of user requests

Action

No action required


XCO0029I Highest number of active users = :1:
Explanation

Output of command XUSER reporting the highest number of user requests

Action

No action required


XCO0030I Number of active CQE-S = :1:.
Explanation

Output of command XCQES reporting the current number of user requests.

Action

No action required.


XCO0031I Highest number of active CQE-S = :1:.
Explanation

Output of command XCQES reporting the highest number of user requests.

Action

No action required.


XCO0032I Parameters for this session:.
Explanation

Output of command XPARM.

Action

No action required.


XCO0033I SVC number = :1:.
Explanation

Output of command XPARM reporting the used SVC number on z/OS or z/VSE.

Action

No action required.


XCO0034I Node number = :1:.
Explanation

Output of command XPARM reporting the ESY node number.

Action

No action required.


XCO0035I CQE number = :1:.
Explanation

Output of command XPARM reporting the startup parameter NCQE.

Action

No action required.


XCO0036I NAB number = :1:.
Explanation

Output of command XPARM reporting the startup parameter NABS.

Action

No action required.


XCO0037I User-application = :1:.
Explanation

Output of command XPARM reporting the name of MAIN function.

Action

No action required.


XCO0039I Total number of commands = :1:.
Explanation

Output of command XSTAT reporting the accumulated number of received user requests.

Action

No action required.


XCO0041E Invalid operator command.
Explanation

An invalid operator command was entered.

Action

Correct it.


XCO0043E Error during request of memory.
Explanation

Not enough memory available. X-COM nucleus terminates abnormally.

Action

Check your environment for available memory.


XCO0044E Error during release of memory.
Explanation

Error in FREEMAIN/FREEVIS/RELM.

Action

Contact Software AG Support.


XCO0045E OPER command init error.
Explanation

Adabas operator command interface could not be established. X-COM nucleus terminates abnormally.

Action

Contact Software AG Support.


XCO0046E Add CQHAECB error.
Explanation

Adabas could not add the command queue to the ECB wait list. X-COM nucleus terminates abnormally.

Action

Contact Software AG Support.


XCO0047E Add user ECB error.
Explanation

Adabas could not add the user ECB to the ECB wait list. X-COM nucleus terminates abnormally.

Action

Contact Software AG Support.


XCO0048E WAIT error.
Explanation

The central wait routine has returned an unrecoverable error. X-COM nucleus terminates abnormally.

Action

Contact Software AG Support.


XCO0050E MPM20-error.
Explanation

The Terminate-Target call was unsuccessful. Shutdown will continue.

Action

Contact Software AG Support.


XCO0051W MPM08-error, user gone.
Explanation

The Get-User-Buffer call was unsuccessful. The user is probably not active any longer. Entire System Server purged this request from the queue.

Action

No action required.


XCO0052W MPM12-error, user gone.
Explanation

The Post-User call was unsuccessful. The user is probably not active anymore. Entire System Server has purged this reply from the queue.

Action

No action required.


XCO0053W MPM36-OK, user gone.
Explanation

The timeout call (TIME elapsed) for a user was successful. The user is probably not active anymore. Entire System Server has purged this reply from the queue.

Action

No action required.


XCO0054W MPM36-error, user not gone.
Explanation

The timeout call (TIME elapsed) for a user was unsuccessful. Entire System Server has tried to purge the user, but the user fetched data back at the last moment.

Action

No action required.


XCO0055I Node currently :1:.
Explanation

Output of command XSTAT. Possible value for :1: are ACTIVE (normal state) or HALTED (node is halted due to operator command XHALT).

Action

No action required.


XCO0057I OPERATOR ENTRY :1:.
Explanation

Display operator entry status: active or inactive.

Action

No action required.


XCO0061W CANNOT LOCATE SUBSYSTEM MODULE :1:.
Explanation

The loading of module :1: failed.

Action

Check and verify whether the module :1: is in the library concatenation. If not, add the appropriate library containing the module :1:. Restart Broker.


XCO0062W Request for active user found, delete old user.
Explanation

There is already an active request for the user requesting a new call. The old session is queued for logoff and the new request has been assigned to a new session. The X-COM nucleus has removed the old resources used on the transport level.

Action

No action required.


XCO0063E BAD PARM CARD: :1:.
Explanation

The parameter line :1: being currently processed is invalid.

Action

Correct the parameter line :1:. Restart Broker.


XCO0077I Attached buffers above 16M line.
Explanation

Adabas Attached Buffers are allocated above the 16 MBytes line.

Action

No action required.


XCO0078E No space for new user X-COM block.
Explanation

The number of free user X-COM blocks has been exceeded. This number depends on the NCQE parameter. Usually a command queue overflow will occur if the number of parallel user requests is exceeded. X-COM nucleus terminates abnormally due to data inconsistencies.

Action

Contact Software AG Support.


XCO0080E MPM24-error, environment not established.
Explanation

The Establish-Adabas-Environment call has failed. The Entire System Server terminates abnormally.

Action

Contact Software AG Support.


XCO0081E MPM00-error, target not initialized.
Explanation

The Initialize-Adabas-Target call has failed. The Entire System Server terminates abnormally.

Action

Contact Software AG Support.


XCO0082I :1:.
Explanation

TRACE data output.

Action

No action required.


XCO0083W Duplicate WAIT ECB. User cleaned up.
Explanation

After successful return from request handler: The user was already waiting. The new request is accepted and the old command queue entry is purged. The old ECB is reused for the new request.

Action

No action required.


XCO0084W Multiple active requests. Delete old.
Explanation

After successful return from reply handler: The command queue element of the user is not unique. Another element has been found with the same cross memory post information (z/OS only). The old request has been purged and the reply for the new request has been initiated. This occurs only if a task has been cancelled and immediately restarted and if the same ASCB has been reused.

Action

No action required.


XCO0085W Reply handling cancelled. Illegal ECB.
Explanation

After successful return from reply handler: the reply cannot be delivered. The command queue element of the user is not unique. Another element has been found with the same cross-memory post information (z/OS only). The reply currently processed is obsolete and has been purged. This occurs only if a task has been cancelled and immediately restarted and if the same ASCB has been reused.

Action

No action required.


XCO0086I APPL ECB: :1:.
Explanation

This message provides information on the address of an Event Control Block. It is issued only in conjunction with other messages.

Action

No action required.


XCO0087E MPM12-ERROR, CQE is not active.
Explanation

Attempt to perform MPM12 function, but the command queue element (CQE) is not active.

Action

No action required.


XCO0088I Dead XCOM block killed.
Explanation

XCOM user has gone away; so skip reply processing.

Action

No action required.


XCO0089E MPM36 impossible because CQE not active.
Explanation

The MPM36 timeout function is skipped, since the command queue element (CQE) is not active.

Action

No action required.


XCO0091I SVC NOT SPECIFIED, SO THIS XCOM COMMAND IS NOT ALLOWED.
Explanation

This informational message indicates that the XCOM operator command issued to the Broker is not allowed, since the Adabas SVC number for EntireX Broker access was set to zero in the startup parameters.

Action

No action required.


XCO0095E NCQE IS LOWER THAN NUM-WQE
Explanation

The number of command queue entries (NCQE) specified is less than the number of work queue entries (NUM-WQE) requested. NCQE defines the number of requests active at one time using the NET transport. NUM-WQE defines the number of requests active at one time for all transports.

Action

Ensure that the value for the number of command queue entries (NCQE) is equal to or greater than the number of work queue entries (NUM-WQE). Restart Broker


XCO2001E Error during READ of startup parms.
Explanation

Bad file format or I/O error during read of startup parameter file.

Action

Parameter file must be a SAM or an ISAM file with variable or fixed record length.


XCO2002E More than :1: parameter cards not possible.
Explanation

The maximum number :1: of startup parms is exceeded.

Action

Reduce the number of startup parm cards in your parameter file. Check the default values of the parameters to avoid setting the values explicitly.


XCO2003E LOAD for module :1: failed - abend.
Explanation

Module :1: could not be found. You need Entire System Server or Adabas libraries with module :1: to start the Entire System Server.

Action

Copy the missing module into your library and start the Entire System Server again. Do not rename modules in the load libraries, e.g. from NAME to NAME.OLD. It could create problems during load.


XCO2004E X-COM abended.
Explanation

An unrecoverable error has occurred. X-COM terminates abnormally.

Action

Look at the previous error messages of X-COM.


XCO2005E Wrong X-COM parameter :1:.
Explanation

An invalid value for :1: was specified in startup parameters.

Action

Verify Entire System Server startup parameter :1: and set a proper value.


XCO2006E ADAMPM - wrong version found.
Explanation

The loaded module ADAMPM has a wrong version.

Action

Check your Adabas library or Contact Software AG Support.


XCO2007E BS2000 V.2 or above is required.
Explanation

The Entire System Server is compiled for BS2000 Version 2 or above. It cannot run on OSD Version 1 or below.

Action

Upgrade of BS2000 is required.


XCO2008E MPM12-error, CQE is not active.
Explanation

The Post-User call has been rejected due to bad status of command queue element. The reply cannot be delivered.

Action

No action required.


XCO2009E MPM36 impossible because CQE not active.
Explanation

The timeout call (TIME elapsed) has been rejected due to bad status of command queue element.

Action

No action required.


XCO2010E Macro :1: RC :2:.
Explanation

The BS2000 macro :1: has returned an error. :2: contains the return code. X-COM nucleus terminates abnormally.

Action

Contact Software AG Support if return code does not explain the problem.


XCO2011E MAIN MP - Macro :1: RC :2:.
Explanation

The ESY MAIN memory pool creation has been aborted. The BS2000 macro :1: has returned an error. :2: contains the return code. X-COM nucleus terminates abnormally.

Action

Contact Software AG Support if return code does not explain the problem.


XCO2012E STACK FAILURE in function :1:.
Explanation

The internal stack is corrupted. :1: identifies the failed function. X-COM nucleus terminates abnormally.

Action

Contact Software AG Support.


XCO2013E Incompatible Adabas version detected.
Explanation

This version of Adabas is no longer supported. An XS-enabled library is required to run with Entire System Server. X-COM nucleus terminates abnormally.

Action

Upgrade of Adabas is required.


XCO2014E MAIN MP - Requested space exceeded.
Explanation

The allocated memory size is not sufficient to contain all required data structures of Entire System Server. X-COM nucleus terminates abnormally.

Action

Contact Software AG Support.


XCO2015E Unrecoverable error in function :1:.
Explanation

A function called by the X-COM nucleus has returned an error response. :1: identifies the called function. X-COM nucleus terminates abnormally.

Action

Contact Software AG Support.