This page describes all Adabas ADASVC messages. Some of these messages may occur during installation of EntireX. Not all messages are applicable to EntireX.
ADASIP01 | ADASIP02 | ADASIP03 | ADASIP04 | ADASIP05 | ADASIP06 | ADASIP07 | ADASIP08 | ADASIP09 | ADASIP10 | ADASIP11 | ADASIP12 | ADASIP13 | ADASIP14 | ADASIP15 | ADASIP17 | ADASIP18 | ADASIP19 | ADASIP20 | ADASIP21 | ADASIP22 | ADASIP23 | ADASIP24 | ADASIP27 | ADASIP28 | ADASIP29 | ADASIP30 | ADASIP31 | ADASIP32 | ADASIP33 | ADASIP34 | ADASIP36 | ADASIP40 | ADASIP41 | ADASIP50 | ADASIP60 | ADASIP61 | ADASIP62 | ADASIP63 | ADASIP64 | ADASIP65 | ADASIP66 | ADASIP67 | ADASIP68 | ADASIP69 | ADASIP70 | ADASIP71 | ADASIP72 | ADASIP73 | ADASIP74 | ADASIP75 | ADASIP76 | ADASIP77 | ADASIP78
ADASIP01 | SUBSID MACRO ERROR |
Explanation |
ADASIP received a non-zero return code from the operating system. |
Action |
The VSE operating system release level is too low for installing Adabas. Refer to the Adabas Installation Manual for the minimum allowed VSE levels. |
ADASIP02 | UNSUPPORTED VSE RELEASE BASED UPON SUBSID |
Explanation |
An ADASIP validation check indicates an unsupported operating system level. |
Action |
The VSE operating system release level is too low for installing Adabas. Refer to the Adabas Installation Manual for the minimum allowed VSE levels. |
ADASIP03 | NO SYSPARM VALUE SPECIFIED FOR SVC |
Explanation |
ADASIP could not find a SYSPARM input, and a ZAP has not be applied to the specified SVC. |
Action |
Either provide the SVC with SYSPARM or apply a ZAP to the specified SVC with ADASIP. |
ADASIP04 | DEFAULT VALUE USED FOR THE SVC |
Explanation |
No SYSPARM SVC has been used. ADASIP defaults to using the SVC that has a ZAP applied. |
Action |
This message is for your information only; no error has occurred. |
ADASIP05 | NON-NUMERIC DATA FOUND IN SYSPARM FIELD |
Explanation |
Either SYSPARM or the default ADASIP SVC contains a nonnumeric value. |
Action |
Correct the specified SYSPARM value, or set the default SVC value to 30. |
ADASIP06 | INVALID RANGE SPECIFIED FOR THE SVC 31-120 |
Explanation |
ADASIP found an SVC outside the allowed range in SYSPARM or the ADASIP default SVC. |
Action |
Set the SVC to an unused SVC value within the allowed range. SVC ranges and recommended values are described in the Adabas Installation Manual. |
ADASIP07 | SVC SPECIFIED NOT WITH VALID RANGE - NO UPSI |
Explanation |
The value specified for the SVC in the VSE SYSPARM with the UPSI option was incorrect. SVC ranges and recommended values are described in the Adabas Installation Manual. |
Action |
Correct the UPSI or SVC value, as appropriate. |
ADASIP08 | ADASVCvv WAS NOT FOUND IN THE SVA |
Explanation |
While performing a VSE load, ADASIP found that the specified level ADASVC was not in the SVA. |
Action |
Issue the SET SDL for ADASVCvv. You may need to relink the Adabas SVC with SVA using the PHASE statement if the Adabas SVC is not found in the Adabas library. |
ADASIP09 | NO MATCH ON ID - INCORRECT ADASVC LOADED |
Explanation |
ADASIP found an incorrect SVC version while attempting a load operation. |
Action |
Relink ADASVCvv with the correct SVC module. |
ADASIP10 | NO KEYWORD SPECIFIED FOR NRIDTES |
Explanation |
ADASIP found an incorrect NRIDTES keyword. |
Action |
Respecify the keyword parameter as NRIDTES=nn, where "nn" specifies the number of databases to be supported in the ID table. |
ADASIP11 | NON-NUMERIC DATA SPECIFIED FOR NRIDTES |
Explanation |
The ADASIP NRIDTES= keyword parameter specified non-numeric data. |
Action |
Correct the NRIDTES= data, then resubmit ADASIP. |
ADASIP12 | NO OVERRIDING NRIDTES SPECIFIED |
Explanation |
The default NRIDTES was used. No error has occurred. |
Action |
None required. This message is for your information only. |
ADASIP13 | SVC TABLE ENTRY WAS FOUND TO BE INVALID |
Explanation |
The SVC number provided by SYSPARM is either not valid, or does not represent either the old or new version of the VSE Adabas SVC. This error can occur if the UPSI statement's C parameter specified 0. |
Action |
Respecify the UPSI statement, or specify another unused SVC value. Rerun ADASIP. |
ADASIP14 | GETVIS FAILURE FOR IDT IN SVA |
Explanation |
The GETVIS of the IDT passed a nonzero return code back to ADASIP, meaning the GETVIS size was insufficient. |
Action |
Increase the SVA GETVIS size, re-IPL the operating system, and rerun ADASIP. |
ADASIP15 | ROUTER UNABLE TO INITIALIZE IDT |
Explanation |
ADASIP received a nonzero return code from the 56 call to the SVC. |
Action |
Contact Software AG Support. |
ADASIP17 | INCORRECT SVC SUFFIX AFTER COMMA IN SYSPARM |
Explanation |
An attempt was made to run this program more than once for the current IPL. A second IDT for the program is not required. |
Action |
Correct the SYSPARM specification for the two-byte SVC suffix, and rerun the job. |
ADASIP18 | NON-NUMERIC DATA SPECIFIED FOR DMPDBID |
Explanation |
The ADASIP DMPDBID keyword parameter contains nonnumeric data. |
Action |
Correct the DMPDBID specification, and rerun the job. |
ADASIP19 | DBID CANNOT BE FOUND IN IDTE |
Explanation |
The ADASIP program could not find an entry for the DMPDBID database in the IDT area. |
Action |
Either correct the DMPDBID specification or start the specified database, then run ADASIP to perform a "snap" dump of the command queue. |
ADASIP20 | THE IDT AND SVC HAVE BEEN DUMPED TO SYSLST |
Explanation |
A request to ADASIP to dump the IDT and then SVC via UPSI 80. |
Action |
This message is for your information only; no error has occurred. |
ADASIP21 | NO IDT TABLE WAS FOUND FOR SPECIFIED SVC |
Explanation |
ADASIP found that the SVC has no address for the IDT. |
Action |
Specify the correct SVC, or initialize with ADASIP first. |
ADASIP22 | THE SVC HAS ALREADY BEEN INSTALLED |
Explanation |
ADASIP found that the same program is being run again. |
Action |
The SVC is not installed and no IDT table is needed. To reinstall the same SVC, you must first perform a SET SDL. |
ADASIP23 | THE SVC TABLE CANNOT BE LISTED UNDER DOS/MVT |
Explanation |
The option to display the SVC table is specified under VSE. |
Action |
None required. This message is for your information only. |
ADASIP24 | THE IDT HAS BEEN PAGEFIXED BY USER OPTION |
Explanation |
UPSI (X'20') was selected to pagefix the IDT in the system GETVIS area. |
Action |
None required. This message is for your information only. |
ADASIP27 | ADASVC IS RMODE=ANY |
Explanation |
ADASIP detected that the Adabas SVC is linked RMODE=ANY. |
Action |
Relink the Adabas SVC RMODE=24. |
ADASIP28 | ADASIP IS AMODE=31 |
Explanation |
ADASIP detected that it is AMODE=31. |
Action |
Relink ADASIP AMODE=24. |
ADASIP29 | PRODID MACRO FAILURE |
Explanation |
ADASIP received a nonzero response code from the PRODID DEFINE macro. |
Action |
Investigate the cause of the error. Correct it and rerun the job. |
ADASIP30 | ADASVCvv svc INSTALLED |
Explanation |
ADASIP has installed SVC number svc successfully. |
Action |
None required. |
ADASIP31 | address=SVC ADDRESS |
Explanation |
The SVC has been loaded at the indicated address. |
Action |
None required. This message is for your information only. |
ADASIP32 | address=IDT ADDRESS |
Explanation |
The ID table has been allocated at the indicated address. |
Action |
None required. This message is for your information only. |
ADASIP33 | address=ALET TABLE ADDRESS |
Explanation |
The ALET table has been loaded at the indicated address. |
Action |
None required. This message is for your information only. |
ADASIP34 | count=MAXIMUM USER/TARGET COMBINATIONS |
Explanation |
Total number of client/server combinations within the VSE system. |
Action |
None required. This message is for your information only. |
ADASIP36 | address=EXTENDED IIBS ADDRESS |
Explanation |
The extended IIBs have been loaded at the indicated address. |
Action |
None required. This message is for your information only. |
ADASIP40 | VSE SVC svc IS status AM=a-mode RM=r-mode AR=reg-mode SVCT=svc-tab-addr MODT=svc-mod-addr | ||||||||||||||||
Explanation |
This message occurs when the option to list the SVC table is selected, and specifies the following values:
|
||||||||||||||||
Action |
None required. This message is for your information only. Note: |
ADASIP41 | VSE SVC TABLE AUDIT COMPLETED |
Explanation |
ADASIP has completed listing the VSE SVC table. |
Action |
None required. This message is for your information only. |
ADASIP50 | THE COMMAND QUEUE HAS BEEN DUMPED TO SYSLST |
Explanation |
ADASIP has completed listing the command queue for the specified database. |
Action |
None required. This message is for your information only. |
ADASIP60 | ONLY 1 CPU CAN BE ACTIVE DURING ADASIP |
Action |
Use |
ADASIP61 | RERUN ADASIP AFTER USING TDSERV TO STOP CPUS |
Explanation |
Occurs in conjunction with ADASIP60. |
ADASIP62 | GETVIS FAILED FOR ADASTUB MODULE |
Explanation |
Not enough SVA storage to load ADASTUB. |
Action |
Consult with your system programmer. |
ADASIP63 | ADASTUB MODULE LOADED AT address |
Explanation |
Information message indicating module load address. |
ADASIP64 | NO MATCH ON ID - INCORRECT ADASTUB LOADED |
Explanation |
ADASTUB phase is incorrect. |
Action |
Consult with your system programmer, or contact Software AG. |
ADASIP65 | ADASTUB SVC TABLE NOT FOUND |
Explanation |
ADASTUB phase is incorrect. |
Action |
Consult with your system programmer, or contact Software AG. |
ADASIP66 | ADASTUB SVC TABLE IS FULL |
Explanation |
You have more than 10 SVCs active on this VSE machine. |
Action |
Contact Software AG for information about increasing the table size. |
ADASIP67 | PAGEFIX FOR ADASIP FAILED |
Action |
Increase the SETPFIX value and rerun. |
ADASIP68 | PAGEFREE FOR ADASIP FAILED |
Action |
Consult with your system programmer. |
ADASIP69 | TURBO DISPATCHER STUB A C T I V E |
Explanation |
Adabas Turbo support is now active on this VSE machine. |
ADASIP70 | VSE SUPERVISOR HOOK INSTALL FAILED |
Explanation |
Either this version of the VSE/ESA 2 supervisor is not supported, or the vendor installation logic for the first-level interrupt handler is incorrect. |
Action |
Contact Software AG Support and have message ADASIP72 available. |
ADASIP71 | LOAD OF MODULE ADASTUB FAILED |
Explanation |
The ADASTUB module was not found in the LIBDEF SEARCH chain. |
ADASIP72 | CODE IS : xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx |
Explanation |
Occurs after message ADASIP70. |
ADASIP73 | ADANCHOR INCORRECT OR NOT FOUND IN SVA |
Explanation |
The ADANCHOR module was not found in the SVA; no SET SDL has been done. |
ADASIP74 | INFO : STUB ACTIVATED BY PREVIOUS ADASIP |
Explanation |
Adabas Turbo STUB has been installed by a previous ADASIP. |
Action |
None. This message is for information only. |
ADASIP75 | ADANCHOR AND ADASTUB NOT DUMPED - NOT ACTIVE |
Explanation |
When attempting to dump Adabas control blocks with ADASIP, the modules were not dumped because Adabas Turbo support is not active. |
Action |
None. This message is for information only. |
ADASIP76 | ADABAS TURBO STUB NOT ACTIVATED DUE TO ERROR |
Explanation |
An error occurred during the installation of the Adabas Turbo stub. |
ADASIP77 | THIS ADABAS SVC WILL RUN IN NON-TURBO MODE |
Explanation |
An error occurred during the installation of the Adabas Turbo stub. This SVC will run in non-Turbo mode from now on. |
ADASIP78 | VSE TURBO DISPATCHER VERSION nn |
Explanation |
Version of VSE/ESA version 2 Turbo Dispatcher. 00 indicates TD level of pre-version 4. |
Action |
None. This message is for information only. |