Writing Applications with the Natural Wrapper

This document covers the following topics:


Writing RPC Clients for RPC-ACI Bridge in Natural

Prerequisites

The parameters of the IDL program must contain an A field with a length of at least 254 bytes or of unlimited length. You need to have dynamic data types in your IDL. You must use COMPR=2 (send buffer completion).

Writing a Natural Client

Start of instruction setTo write a Natural client

  1. Use CALLNAT for the Natural RPC client.

  2. Provide a context for EntireX as described under Interface RPC-CNTX for the Natural RPC Client Programmer below. See the Natural documentation for details.

The RPC-ACI Bridge reports errors on the ACI side or the Broker for ACI with Natural error 998 (Internal error details). The details contain the error number followed by a description. Use Natural subroutine USR2030N to retrieve error class, error code and description. The error class for the RPC-ACI Bridge is 1018. See Message Class 1018 - EntireX RPC-ACI Bridge.

For error handling, use for example (the declarations of the variables are omitted):

ON ERROR
  IF *ERROR-NR = 998 THEN
    CALLNAT 'USR2030N' ERR-PARM(*) OCC RESPONSE
    IF OCC > 0 THEN
      MOVE SUBSTRING(ERR-PARM(1), 1, 8) to #ERR-CODE
      MOVE SUBSTRING(ERR-PARM(1), 10) to #ERR-DETAIL
      WRITE #ERR-CODE
      WRITE #ERR-DETAIL (AL=79)
      ESCAPE ROUTINE
    END-IF
  END-IF
END-ERROR

Interface RPC-CNTX for the Natural RPC Client Programmer

API RPC-CNTX is used for providing a context for RPC client applications. RPC-CNTX combines the functionality of several APIs and is available in library SYSTEM. There is no need for extra preparations such as setting a STEPLIB or copying APIs from SYSEXT to user libraries.

RPC-CNTX makes the following interfaces from SYSEXT obsolete: USR1071N, (USR4371N), USR6304N, USR2007N, USR4008, USR4009, USR2071N.

For the usage of RPC-CNTX refer to the test programs generated by the Natural Wrapper, see Sample Generation Result for the Client Side.

For further information refer to the Natural RPC documentation.

Returning Application Errors from an RPC Server to an RPC Client

Application error codes enable the RPC server to return customer-invented errors back to the RPC client in a standardized way without defining an error code field in the IDL file.

USR4012N from Natural library SYSEXT may be used to enforce Natural error NAT1999 on the Natural RPC server and to pass back the provided error text to the RPC client.

Example

 /* Application Error
 COMPRESS "ERROR: " #ERR-TEXT INTO #LOG-TEXT
 /* Send back Application Error to Client
 CALLNAT 'USR4012N' USING #ERR-TEXT

For more information:

Interfaces (APIs) Available in SYSEXT

The Natural library SYSEXT provides APIs for RPC programming. Log on to the library SYSEXT and enter MENU. To list only RPC-related APIs, enter the keyword RPC. To make these APIs available, make the necessary STEPLIP settings or copy the APIs from SYSEXT to user libraries. For more information, refer to the API documentation provided by SYSEXT.

Interface Comment
USR1071N Set user ID and password for RPC
USR2007N Set/get RPC default server information.
USR2015N EBCDIC or ASCII translation table for Natural RPC.
USR2032N Support of commit for CLOSE CONVERSATION.
USR2035N Support of SSL.
USR2071N Support of EntireX Security on client side.
USR2072N Support of EntireX Security on server side.
USR2073N Ping or terminate an RPC server.
USR2074N Set new password for NSC user in RPC context.
USR2075N Terminate EntireX Broker service.
USR4008N Set library for RPC execution.
USR4009N Set parameters for EntireX.
USR4010N Retrieve runtime settings of server.
USR4012N Support of application error.
USR4371N Set user ID and ETID for RPC.
USR6304N Set/get reliable state for RPC execution.
USR6305N Commit/rollback reliable RPC message(s).
USR6306N Status of UOWs of current EntireX Broker user.
etc.  

Using SSL/TLS

RPC client applications can use Secure Sockets Layer/Transport Layer Security (SSL/TLS) as the transport medium. The term "SSL" in this section refers to both SSL and TLS. RPC-based clients are always SSL clients. The SSL server can be either the EntireX Broker or Direct RPC in webMethods Integration Server (IS inbound). For an introduction see SSL/TLS and Certificates with EntireX in the Platform-independent Administration documentation. This section describes using SSL with the Natural Wrapper on the following platforms:

z/OS

SSL delivered on a z/OS mainframe will typically use the Resource Access Control Facility (RACF) as the certificate authority (CA). Certificates managed by RACF can only be accessed through the RACF keyring container. A keyring is a collection of certificates that identify a networking trust relationship (also called a trust policy). In an SSL client/server network environment, entities identify themselves using digital certificates called through a keyring. Server applications on z/OS that wish to establish network connections to other entities can use keyrings and their certificate contents to determine the trustworthiness of the client or peer entity. Note that certificates can belong to more than one keyring, and you can assign different users to the same keyring. Because of the way RACF internally references certificates, they must be uniquely identifiable by owner and label, and also unique by serial number plus data set name (DSN).

For establishing an SSL connection on z/OS, IBM's Application Transparent Transport Layer Security (AT-TLS) can be used, where the establishment of the SSL connection is pushed down the stack into the TCP layer.

With the Natural Wrapper you can use IBM's Application Transparent Transport Layer Security (AT-TLS), where the establishment of the SSL connection is pushed down the stack into the TCP layer.

Using IBM's Application Transparent Transport Layer Security (AT-TLS)

Configure the AT-TLS rules for the policy agent (PAGENT) graphics/no4.gif using an appropriate client graphics/no1.gif and the z/OS Management Facility (z/OSMF) graphics/no2.gif. Together with SSL parameters (to provide certificates stored in z/OS as RACF keyrings) define AT-TLS rules, for example by using the application graphics/no5.gif job name and remote TCP port number. If the rules match, the TCP connection is turned into an SSL connection graphics/no6.gif. Refer to your IBM documentation for more information, for example the IBM Redbook Communications Server for z/OS VxRy TCP/IP Implementation Volume 4: Security and Policy-Based Networking.

graphics/adminRpc_ssl_config-nat.png

graphics/no1.gif Client to interact with z/OS Management Facility (z/OSMF).
graphics/no2.gif AT-TLS rules are defined with z/OSMF policy management.
graphics/no3.gif Policy Repository with AT-TLS rules stored as z/OS files.
graphics/no4.gif Policy Agent, MVS task PAGENT, provides AT-TLS rules through a policy enforcement point (PEP) to TCP/IP stack.
graphics/no5.gif Application using TCP connection.
graphics/no6.gif If AT-TLS rules match, the TCP connection is turned into an SSL connection.

Notes:

  1. The client graphics/no1.gif may vary per operating system, for example a Web browser for z/OS 2.1.
  2. z/OSMF graphics/no2.gif includes other administration and management tasks in addition to policy management.
  3. Policy Management graphics/no3.gif includes other rules, such as IP filtering, network address translation etc.

Start of instruction setTo set up SSL with AT-TLS

  1. To operate with SSL, certificates need to be provided and maintained. Depending on the platform, Software AG provides default certificates, but we strongly recommend that you create your own. See SSL/TLS Sample Certificates Delivered with EntireX in the EntireX Security documentation.

  2. Set up the RPC component for a TCP/IP connection. On mainframe platforms, use Transport-method-style Broker ID. Example:

    ETB024:1699:TCP
  3. Configure AT-TLS to turn the TCP/IP connection to an SSL connection, see above.

  4. Make sure the SSL server to which the RPC component connects is prepared for SSL connections as well. The SSL server can be EntireX Broker, Broker SSL Agent, or Direct RPC in webMethods Integration Server (IS inbound). See:

z/VSE

Establishing an SSL connection on z/VSE requires BSI's Automatic Transport Layer Security (ATLS). This facility is similar to z/OS Application Transparent - Transport Layer Security (AT-TLS). ATLS is supported by the BSI stack only.

Using BSI's Automatic Transport Layer Security (ATLS)

Together with SSL parameters (to provide certificates), define ATLS rules for socket interception in the ATLS daemon startup job BSTTATLS graphics/no2.gif. If the rules match, the socket connection is turned into an SSL connection graphics/no5.gif. Refer to your IBM documentation for further information. For an overview, refer to the IBM Redbook Enhanced Networking on IBM z/VSE; for a more detailed description, refer to BSI SSL Installation, Programming and User's Guide.

graphics/adminRpc_ssl_config-vse.png

graphics/no1.gif BSI TCP/IP Stack, either BSTTINET (IPv4) or BSTT6NET (IPv6).
graphics/no2.gif ATLS rules are defined manually. See Sample ATLS Daemon Configuration below.
graphics/no3.gif BSTTATLS is associated with a TCP/IP stack.
graphics/no4.gif Application using TCP connection.
graphics/no5.gif BSTTATLS intercepts outbound TCP connection and converts it to SSL connection. For inbound, SSL connections can also be intercepted and converted to TCP connections.

Start of instruction setTo set up SSL with ATLS

  1. To operate with SSL, certificates need to be provided and maintained. Depending on the platform, Software AG provides default certificates, but we strongly recommend that you create your own. See SSL/TLS Sample Certificates Delivered with EntireX in the EntireX Security documentation.

  2. Set up the RPC component for a TCP/IP connection. On mainframe platforms, use Transport-method-style Broker ID. Example:

    ETB024:1699:TCP
  3. Configure ATLS to turn the TCP/IP connection to an SSL connection, see above.

  4. Make sure the SSL server to which the RPC component connects is prepared for SSL connections as well. The SSL server can be EntireX Broker, Broker SSL Agent, or Direct RPC in webMethods Integration Server (IS inbound). See:

Sample ATLS Daemon Configuration

* Converting inbound EntireX Broker connection 
* Converts listen port 1971 to SSL listen port 1972
OPTION SERVER 
ATTLS 1971 AS 2071 SSL
*
* Converting outbound client connection
* Converts connect to 192.168.2.100:1972:TCP to 192.168.2.100:2072:SSL
OPTION CLIENT
ATTLS 1972 TO 192.168.2.100 AS 2072 SSL

Note:
We recommend setting SETPARM value SUBTASK to a value greater than 0 in the ATLS daemon startup job (valid values 0-16, default=0). For example:

// SETPARM SUBTASK=8

See also BSI SSL Installation, Programming and User's Guide.