Adabas SVC Installation Messages (ADASIP)

This page describes all Adabas ADASVC messages. Some of these messages may occur during installation of EntireX. Not all messages are applicable to EntireX.

Overview of Messages

ADASIP01 | ADASIP02 | ADASIP03 | ADASIP04 | ADASIP05 | ADASIP06 | ADASIP07 | ADASIP08 | ADASIP09 | ADASIP10 | ADASIP11 | ADASIP12 | ADASIP13 | ADASIP14 | ADASIP15 | ADASIP17 | ADASIP18 | ADASIP19 | ADASIP20 | ADASIP21 | ADASIP22 | ADASIP23 | ADASIP24 | ADASIP27 | ADASIP28 | ADASIP29 | ADASIP30 | ADASIP31 | ADASIP32 | ADASIP33 | ADASIP34 | ADASIP36 | ADASIP40 | ADASIP41 | ADASIP50 | ADASIP60 | ADASIP61 | ADASIP62 | ADASIP63 | ADASIP64 | ADASIP65 | ADASIP66 | ADASIP67 | ADASIP68 | ADASIP69 | ADASIP70 | ADASIP71 | ADASIP72 | ADASIP73 | ADASIP74 | ADASIP75 | ADASIP76 | ADASIP77 | ADASIP78

ADASIP01 SUBSID MACRO ERROR
Explanation

ADASIP received a non-zero return code from the operating system.

Action

The VSE operating system release level is too low for installing Adabas. Refer to the Adabas Installation Manual for the minimum allowed VSE levels.


ADASIP02 UNSUPPORTED VSE RELEASE BASED UPON SUBSID
Explanation

An ADASIP validation check indicates an unsupported operating system level.

Action

The VSE operating system release level is too low for installing Adabas. Refer to the Adabas Installation Manual for the minimum allowed VSE levels.


ADASIP03 NO SYSPARM VALUE SPECIFIED FOR SVC
Explanation

ADASIP could not find a SYSPARM input, and a ZAP has not be applied to the specified SVC.

Action

Either provide the SVC with SYSPARM or apply a ZAP to the specified SVC with ADASIP.


ADASIP04 DEFAULT VALUE USED FOR THE SVC
Explanation

No SYSPARM SVC has been used. ADASIP defaults to using the SVC that has a ZAP applied.

Action

This message is for your information only; no error has occurred.


ADASIP05 NON-NUMERIC DATA FOUND IN SYSPARM FIELD
Explanation

Either SYSPARM or the default ADASIP SVC contains a nonnumeric value.

Action

Correct the specified SYSPARM value, or set the default SVC value to 30.


ADASIP06 INVALID RANGE SPECIFIED FOR THE SVC 31-120
Explanation

ADASIP found an SVC outside the allowed range in SYSPARM or the ADASIP default SVC.

Action

Set the SVC to an unused SVC value within the allowed range. SVC ranges and recommended values are described in the Adabas Installation Manual.


ADASIP07 SVC SPECIFIED NOT WITH VALID RANGE - NO UPSI
Explanation

The value specified for the SVC in the VSE SYSPARM with the UPSI option was incorrect. SVC ranges and recommended values are described in the Adabas Installation Manual.

Action

Correct the UPSI or SVC value, as appropriate.


ADASIP08 ADASVCvv WAS NOT FOUND IN THE SVA
Explanation

While performing a VSE load, ADASIP found that the specified level ADASVC was not in the SVA.

Action

Issue the SET SDL for ADASVCvv. You may need to relink the Adabas SVC with SVA using the PHASE statement if the Adabas SVC is not found in the Adabas library.


ADASIP09 NO MATCH ON ID - INCORRECT ADASVC LOADED
Explanation

ADASIP found an incorrect SVC version while attempting a load operation.

Action

Relink ADASVCvv with the correct SVC module.


ADASIP10 NO KEYWORD SPECIFIED FOR NRIDTES
Explanation

ADASIP found an incorrect NRIDTES keyword.

Action

Respecify the keyword parameter as NRIDTES=nn, where "nn" specifies the number of databases to be supported in the ID table.


ADASIP11 NON-NUMERIC DATA SPECIFIED FOR NRIDTES
Explanation

The ADASIP NRIDTES= keyword parameter specified non-numeric data.

Action

Correct the NRIDTES= data, then resubmit ADASIP.


ADASIP12 NO OVERRIDING NRIDTES SPECIFIED
Explanation

The default NRIDTES was used. No error has occurred.

Action

None required. This message is for your information only.


ADASIP13 SVC TABLE ENTRY WAS FOUND TO BE INVALID
Explanation

The SVC number provided by SYSPARM is either not valid, or does not represent either the old or new version of the VSE Adabas SVC. This error can occur if the UPSI statement's C parameter specified 0.

Action

Respecify the UPSI statement, or specify another unused SVC value. Rerun ADASIP.


ADASIP14 GETVIS FAILURE FOR IDT IN SVA
Explanation

The GETVIS of the IDT passed a nonzero return code back to ADASIP, meaning the GETVIS size was insufficient.

Action

Increase the SVA GETVIS size, re-IPL the operating system, and rerun ADASIP.


ADASIP15 ROUTER UNABLE TO INITIALIZE IDT
Explanation

ADASIP received a nonzero return code from the 56 call to the SVC.

Action

Contact Software AG Support.


ADASIP17 INCORRECT SVC SUFFIX AFTER COMMA IN SYSPARM
Explanation

An attempt was made to run this program more than once for the current IPL. A second IDT for the program is not required.

Action

Correct the SYSPARM specification for the two-byte SVC suffix, and rerun the job.


ADASIP18 NON-NUMERIC DATA SPECIFIED FOR DMPDBID
Explanation

The ADASIP DMPDBID keyword parameter contains nonnumeric data.

Action

Correct the DMPDBID specification, and rerun the job.


ADASIP19 DBID CANNOT BE FOUND IN IDTE
Explanation

The ADASIP program could not find an entry for the DMPDBID database in the IDT area.

Action

Either correct the DMPDBID specification or start the specified database, then run ADASIP to perform a "snap" dump of the command queue.


ADASIP20 THE IDT AND SVC HAVE BEEN DUMPED TO SYSLST
Explanation

A request to ADASIP to dump the IDT and then SVC via UPSI 80.

Action

This message is for your information only; no error has occurred.


ADASIP21 NO IDT TABLE WAS FOUND FOR SPECIFIED SVC
Explanation

ADASIP found that the SVC has no address for the IDT.

Action

Specify the correct SVC, or initialize with ADASIP first.


ADASIP22 THE SVC HAS ALREADY BEEN INSTALLED
Explanation

ADASIP found that the same program is being run again.

Action

The SVC is not installed and no IDT table is needed. To reinstall the same SVC, you must first perform a SET SDL.


ADASIP23 THE SVC TABLE CANNOT BE LISTED UNDER DOS/MVT
Explanation

The option to display the SVC table is specified under VSE.

Action

None required. This message is for your information only.


ADASIP24 THE IDT HAS BEEN PAGEFIXED BY USER OPTION
Explanation

UPSI (X'20') was selected to pagefix the IDT in the system GETVIS area.

Action

None required. This message is for your information only.


ADASIP27 ADASVC IS RMODE=ANY
Explanation

ADASIP detected that the Adabas SVC is linked RMODE=ANY.

Action

Relink the Adabas SVC RMODE=24.


ADASIP28 ADASIP IS AMODE=31
Explanation

ADASIP detected that it is AMODE=31.

Action

Relink ADASIP AMODE=24.


ADASIP29 PRODID MACRO FAILURE
Explanation

ADASIP received a nonzero response code from the PRODID DEFINE macro.

Action

Investigate the cause of the error. Correct it and rerun the job.


ADASIP30 ADASVCvv svc INSTALLED
Explanation

ADASIP has installed SVC number svc successfully.

Action

No action required.


ADASIP31 address=SVC ADDRESS
Explanation

The SVC has been loaded at the indicated address.

Action

None required. This message is for your information only.


ADASIP32 address=IDT ADDRESS
Explanation

The ID table has been allocated at the indicated address.

Action

None required. This message is for your information only.


ADASIP33 address=ALET TABLE ADDRESS
Explanation

The ALET table has been loaded at the indicated address.

Action

None required. This message is for your information only.


ADASIP34 count=MAXIMUM USER/TARGET COMBINATIONS
Explanation

Total number of client/server combinations within the VSE system.

Action

None required. This message is for your information only.


ADASIP36 address=EXTENDED IIBS ADDRESS
Explanation

The extended IIBs have been loaded at the indicated address.

Action

None required. This message is for your information only.


ADASIP40 VSE SVC svc IS status AM=a-mode RM=r-mode AR=reg-mode SVCT=svc-tab-addr MODT=svc-mod-addr
Explanation

This message occurs when the option to list the SVC table is selected, and specifies the following values:

Value Description
svc the VSE SVC number
status USED or UNUSED
a-mode AMODE of this SVC, if used (24 or ANY)
r-mode RMODE of this SVC, if used (24 or ANY)
reg-mode access register mode of this SVC, if used (Y=yes, N=no)
svc-tab-addr address of the SVC table entry for this SVC
svc-mod-addr address of the SVC mode table entry for this SVC, if present
Action

None required. This message is for your information only.

Note:
Do not use SVC50, even though it is indicated as "unused".


ADASIP41 VSE SVC TABLE AUDIT COMPLETED
Explanation

ADASIP has completed listing the VSE SVC table.

Action

None required. This message is for your information only.


ADASIP50 THE COMMAND QUEUE HAS BEEN DUMPED TO SYSLST
Explanation

ADASIP has completed listing the command queue for the specified database.

Action

None required. This message is for your information only.


ADASIP60 ONLY 1 CPU CAN BE ACTIVE DURING ADASIP
Action

Use SYSDEF TD,STOP=ALL to stop all but one CPU so that ADASIP can run. Then restart your CPUs again.


ADASIP61 RERUN ADASIP AFTER USING TDSERV TO STOP CPUS
Explanation

Occurs in conjunction with ADASIP60.


ADASIP62 GETVIS FAILED FOR ADASTUB MODULE
Explanation

Not enough SVA storage to load ADASTUB.

Action

Consult with your system programmer.


ADASIP63 ADASTUB MODULE LOADED AT address
Explanation

Information message indicating module load address.


ADASIP64 NO MATCH ON ID - INCORRECT ADASTUB LOADED
Explanation

ADASTUB phase is incorrect.

Action

Consult with your system programmer, or contact Software AG.


ADASIP65 ADASTUB SVC TABLE NOT FOUND
Explanation

ADASTUB phase is incorrect.

Action

Consult with your system programmer, or contact Software AG.


ADASIP66 ADASTUB SVC TABLE IS FULL
Explanation

You have more than 10 SVCs active on this VSE machine.

Action

Contact Software AG for information about increasing the table size.


ADASIP67 PAGEFIX FOR ADASIP FAILED
Action

Increase the SETPFIX value and rerun.


ADASIP68 PAGEFREE FOR ADASIP FAILED
Action

Consult with your system programmer.


ADASIP69 TURBO DISPATCHER STUB A C T I V E
Explanation

Adabas Turbo support is now active on this VSE machine.


ADASIP70 VSE SUPERVISOR HOOK INSTALL FAILED
Explanation

Either this version of the VSE/ESA 2 supervisor is not supported, or the vendor installation logic for the first-level interrupt handler is incorrect.

Action

Contact Software AG Support and have message ADASIP72 available.


ADASIP71 LOAD OF MODULE ADASTUB FAILED
Explanation

The ADASTUB module was not found in the LIBDEF SEARCH chain.


ADASIP72 CODE IS : xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Explanation

Occurs after message ADASIP70.


ADASIP73 ADANCHOR INCORRECT OR NOT FOUND IN SVA
Explanation

The ADANCHOR module was not found in the SVA; no SET SDL has been done.


ADASIP74 INFO : STUB ACTIVATED BY PREVIOUS ADASIP
Explanation

Adabas Turbo STUB has been installed by a previous ADASIP.

Action

None. This message is for information only.


ADASIP75 ADANCHOR AND ADASTUB NOT DUMPED - NOT ACTIVE
Explanation

When attempting to dump Adabas control blocks with ADASIP, the modules were not dumped because Adabas Turbo support is not active.

Action

None. This message is for information only.


ADASIP76 ADABAS TURBO STUB NOT ACTIVATED DUE TO ERROR
Explanation

An error occurred during the installation of the Adabas Turbo stub.


ADASIP77 THIS ADABAS SVC WILL RUN IN NON-TURBO MODE
Explanation

An error occurred during the installation of the Adabas Turbo stub. This SVC will run in non-Turbo mode from now on.


ADASIP78 VSE TURBO DISPATCHER VERSION nn
Explanation

Version of VSE/ESA version 2 Turbo Dispatcher. 00 indicates TD level of pre-version 4.

Action

None. This message is for information only.