Properties Page | Property | Description |
Implementation | Integration Server Name | Assigned Integration Server Name. |
Receive Protocol or Send Protocol | For a catching event, identifies the type of receive protocol to use. For a throwing event, identifies the type of send protocol to use. Select Subscription (For Publishable Documents), JMS (for JMS Triggered Processes) (default), or EDA (For EDA Event Triggered Processes) from the list. Note: Dragging and dropping an EDA Event Type automatically configures the Receive Protocol to use EDA (For EDA Event Triggered Processes) | |
Receive Document or Send Document | For a catching event, identifies the document type to receive. For a throwing event, identifies the document type to send. Click Browse to open the Choose Document window and locate a service on an Integration Server or in CentraSite. Click New to open the Create a New Document Type window and create a new document on a configured Integration Server. Click View to open the selected document in a document editor. The View button is available only when a document is specified in the Document field. Note: If you drop an IS document or event type onto an existing intermediate message step, this field is automatically populated with the IS document name. Note: Selecting an e-form as the step's Receive Document automatically selects the Enable content repository support check box and enables E-form properties. | |
Receive EDA Event or Send EDA Event | For the EDA protocol only. For a catching event, identifies the document type to receive. For a throwing event, identifies the document type to send. The Integration Server document type associated with the EDA event type is displayed when using EDA (For EDA Event Triggered Processes) as the Receive Protocol or the Send Protocol. This field is not editable. | |
Protocol Properties | Available for JMS and EDA protocols only. Connection Alias. Accept the default PE_NONTRASACTIONAL_ALIAS for JMS or EventBus for EDA, or click Browse to select another alias (an Integration Server connection is required). For more information, see
Configuring a JMS-Triggered
Process and
Configuring an EDA-Triggered
Process. Destination Name. Required. Defined by default as: projectName_ProcessName_ SUBQUEUE. To specify another destination name, click Browse (an Integration Server connection is required). | |
Subscription Filter | For catching events only, not available for EDA protocol: The instances of a subscription document or event that can trigger the process. See
Working with Subscription Filters. | |
Generated Service Name | For catching only: Name of the generated flow service used at run time | |
Retry Count | For catching only: Number of times the Process Engine retries the service in the case of an Integration Server run-time exception. The default value is 0, or no retries. Note: The retry mechanism is invoked only when a step service generates an ISRuntimeException error. Any other exception, such as an EXIT with a FAILURE error, causes the step to fail. | |
Retry Interval | For catching only: Number of milliseconds (ms) the Process Engine waits between retry attempts in the case of an Integration Server run-time exception. The default value is 60000 ms, or 60 seconds. | |
Allow Parallel Execution | Lock the step at run-time to allow it to be executed by multiple threads. | |
E-form | Selecting an e-form as the step's Receive Document automatically selects the Enable content repository support check box and enables E-form properties. For more information on working with e-forms, see
Selecting an E-form Content Repository and the PDF publication Implementing E-form Support for BPM. Important: Incoming e-form instances must have the correct file name extension (for example, .xml for InfoPath forms, .xdp for LiveCycle forms). Otherwise, they will not trigger the receive step. | |
Content Repository | Select Browse to specify a My webMethods Server content repository where e-form instances are monitored by the Process Engine listener. | |
Template Name | Selecting an e-form as the step's Receive Document automatically populates this field. For more information about using e-forms, see
Using E-forms in a Process and the PDF publication Implementing E-form Support for BPM. | |
Logged Fields | Outputs | For catching only: Output fields to log. Outputs are logged after the step executes. For more information, see
Log Inputs and Outputs |
Joins | Join Type | A join type defines the logic the process follows when a step has multiple incoming transitions. Options: OR, AND, COMPLEX, or Unsynchronized OR. For more information, see
About Joins. Note: The Joins page is displayed only when a step has more than one incoming transition. |
Join Timeout | The timeout duration value, after which this join fails. This option is available for AND and COMPLEX joins only. The source of this value can be: A static value that you define. A value from a field in the process pipeline. The field value is interpreted in milliseconds. A value based on a business calendar in My webMethods Server. You can specify a static number of days, hours, and minutes, or specify a pipeline field to set the day, hours, or minutes value. See
About Join Timeouts. | |
Join Condition | Use the join condition editor to define a condition for the join. This option is available only for a complex join. When the terms of this condition are met (that is, the condition is true), the join is considered satisfied. For more information about using the condition editor, see
About Complex Join Expressions and
Defining a Complex Join
Expression. | |
Deprecated properties (not recommended) | These deprecated properties are not available for unsynchronized OR joins. Suppress Join Failure This option is not recommended except in very isolated cases. For more information, see
Migrating Process Models with Join Steps
to Version 9.7 and Later. | |
Ignore dead path notification This option is not recommended except in very isolated cases. For more information, see
Migrating Process Models with Join Steps
to Version 9.7 and Later. | ||
Correlation | Correlation | For catching only: select Not Used, Field, or Service. For more information, see