DevOps Edition for Continuous Integration 10.5 | Integration Server Administrator's Guide | Starting and Stopping the Server | Changing Settings in the Configuration File custom_wrapper.conf
 
Changing Settings in the Configuration File custom_wrapper.conf
The custom_wrapper.conf, which is used at Integration Server startup, contains configuration settings. You can override these settings for a single Integration Server session by starting Integration Server from the command prompt and using switches to override values in the custom_wrapper.conf file. However, you might want to permanently change some of the configuration values in the custom_wrapper.conf so that all sessions use the modified configuration values.
Note: Microservices Runtime does not use the custom_wrapper.conf. For Microservices Runtime, set configuration information in the following file: Integration Server_directory /bin/setenv.bat(sh)
* To override settings in the configuration file
1. In a text editor, open the custom_wrapper.conf file from the following directory:
Software AG_directory \profiles\IS_instance_name\configuration
where instance_name is the name of the Integration Server instance.
2. Add the following property to custom_wrapper.conf:
wrapper.app.parameter.n=switch
where n is the next unused sequential number for the wrapper.app.parameter properties in the file and switch is the switch command.
wrapper.app.parameter.n=switch_parameter
where n is the sequential number and switch_parameter is the value of the switch.
Most switches require that you add an additional property to custom_wrapper.conf as the very next property in the sequence, as follows:
For example, to change the default port number to 8080, you would enter the following to custom_wrapper.conf:
wrapper.app.parameter.7=-port
wrapper.app.parameter.8=8080
For more information about the wrapper.app.parameter property, see Software AG Infrastructure Administrator's Guide.
The following table describes the switches you can use to override settings in the configuration file:
switch
Description
-port
Specifies the port on which the server listens for HTTP requests. If you add a wrapper.app.parameter property to custom_wrapper.conf for the -port switch, you must also add a wrapper.app.parameter property in which you specify the TCP/IP port number to use.
The first wrapper.app.parameter property specifies that you want to override the port by using the -port switch, and the next wrapper.app.parameter property specifies the port number to use. For example:
wrapper.app.parameter.7=-port
wrapper.app.parameter.8=8080
Note: Keep the following points in mind when overriding the port number:
*This switch overrides the value assigned to watt.server.port.
*The -port switch permanently adds a new HTTP port to the WmRoot package. This new port is added as the primary port and contains default values. If a port with the same TCP/IP number already exists in the WmRoot package, the -port switch overrides its settings with the new default values. In effect, deleting the existing port and then adding a new port with default settings.
*To use port 80 (the standard for HTTP) or port 443 (the standard for HTTPS), UNIX users must be running as "root." For security reasons, a better method is to use a higher number port (5555 for HTTP and 8080 for HTTPS), and if necessary have the firewall remap port 80 to the desired port. See Architecture for a discussion of remapping ports.
-debug
Specifies the level of detail you want the server to maintain in its server log for this session. The -debug switch overrides the value specified for the Default facility on the Settings > Logging page and assigned to watt.debug.level.
If you add a wrapper.app.parameter property to custom_wrapper.conf for the -debug switch, you must also add a wrapper.app.parameter property in which you specify the level of detail you want to record in the log. You can specify the following levels:
Specify
To record
Fatal
Fatal messages only.
Error
Error and fatal messages.
Warn
Warning, error, and fatal messages.
Info
Informational, warning, error, and fatal messages.
Debug
Debug, informational, warning, error, and fatal messages.
Trace
Trace, debug, informational, warning, error, and fatal messages.
The first wrapper.app.parameter property specifies that you want to override the debug level by specifying the -debug switch, and the next wrapper.app.parameter property specifies the level of detail you want to record in the log. For example:
wrapper.app.parameter.11=-debug
wrapper.app.parameter.12=fatal
Note: Prior to Integration Server 7.1, Integration Server used a number-based system to set the level of debug information written to the server log. Integration Server maintains backward compatibility with this system. For more information about the number-based logging levels, see the description of the watt.debug.level property in Server Configuration Parameters.
-log
Specifies where you want the server to write its server log information for this session. If you add a wrapper.app.parameter property to custom_wrapper.conf for the -log switch, you must also add a wrapper.app.parameter property in which you specify the destination of the log information. You can specify the following destinations:
Option
Description
filename
Specify the fully qualified path or relative path to the file in which you want the server to write server log information for this session. Relative path is relative to the Integration Server home directory: Integration Server_directory \instances\instance_name
The filename must specify a directory and filename.
The default destination is controlled by the watt.debug.logfile server configuration parameter.
none
Write server log information to the computer screen (STDOUT).
both
Write server log information to the computer screen (STDOUT) and to the destination specified by the watt.debug.logfile parameter.
The first wrapper.app.parameter property specifies that you want to override the destination of the log information by specifying the -log switch, and the next wrapper.app.parameter property specifies either the complete path for the home directory or none. For example:
wrapper.app.parameter.13=-log
wrapper.app.parameter.14=none
Note: A swtich value of filename or none overrides the value assigned to watt.debug.logfile for this session.
Note: A -log switch value of none or both also determines where Microservices Runtime or an Integration Server equipped with an Microservices Runtime license writes the configuration variables log. However, Microservices Runtime ignores a filename value. If you specify a filename,Microservices Runtime writes the configuration variables log file to this location only: Integration Server_directory /instances/instanceName/logs/configurationvariables.log.
-quiesce
Specifies that Integration Server starts the server in quiesce mode. When you add a wrapper.app.parameter property to custom_wrapper.conf for the -quiesce switch, Integration Server starts in quiesce mode. The -quiesce switch does not require an additional wrapper.app.parameter property. For example:
wrapper.app.parameter.15=-quiesce
For more information about quiesce mode, see Quiescing the Server for Maintenance.
3. In the custom_wrapper.conf, update the wrapper.app.parameter.2 property to reflect the total number of wrapper.app.parameter properties that you added in the previous steps.
For example, if wrapper.app.parameter.2 is set to 4 (the default) and you add two wrapper.app.parameter properties, you would increase the value of wrapper.app.parameter.2 by two. After making your edits, the wrapper.app.parameter.2 would appear as follows:
wrapper.app.parameter.2=6
For more information about the wrapper.app.parameter property, see Software AG Infrastructure Administrator's Guide.
4. Save and close custom_wrapper.conf.

Copyright © 2017-2019 | Software AG, Darmstadt, Germany and/or Software AG USA, Inc., Reston, VA, USA, and/or its subsidiaries and/or its affiliates and/or their licensors.