Configuring Integration Server to Work with Servers Running HTTP 1.0 and Above
Sometimes when your Integration Server connects to the partner server, the server may crash before sending back a response. If your Integration Server maintains backward compatibility with HTTP 0.9, it does not mandate a response code and consequently, it treats no response from the target server as a valid response. This is an error.
Integration Server now contains a watt property that you can set to indicate whether it maintains compatibility with another server using HTTP 0.9.
Use the following procedure to update your Integration Server to work with servers running HTTP 1.0 and above only.
To set
Integration Server to work with servers running HTTP 1.0 and above
1. In the Settings menu of the Navigation panel, click Extended.
2. Click Edit Extended Settings.
3. Type watt.server.http.pointnineSupport=false.
4. Click Save Changes.
Note: Set watt.server.http.pointnineSupport to true if you want Integration Server to communicate with servers using HTTP 0.9 and above.