Administering and Monitoring Business Processes 10.4 | Administering and Monitoring Business Processes | webMethods Audit Logging Guide | Setting Up IS Core Audit Logging | Configure Audit Logging | Identify the Destination
 
Identify the Destination
 
File Names and Locations
Database Error Handling
In the Destination area, identify where the logger is to write entries. Any external RDBMSs will have been set up after installation (see Installing Software AG Products).
Note: The messaging audit logger always writes to a file and cannot be configured to write to a database.
In the Maximum Retries field, specify the maximum times the logger should retry writing the entry to the destination if the first attempt fails because of a transient error. A transient error is an error that arises from a temporary condition that might be resolved or corrected quickly, such as the unavailability of a resource due to network issues or failure to connect to a database.
Also set the Wait Between Retries field.
Note: If the logger is logging data asynchronously (see below) and the logging queue has many audit records in it, the elapsed time between logging attempts may be longer than the value in the Wait Between Retries field.
Note: The Maximum Retries field and the Wait Between Retries field do not apply to the messaging audit logger because the messaging audit logger cannot be configured to write to a database.

Copyright © 2019 | Software AG, Darmstadt, Germany and/or Software AG USA, Inc., Reston, VA, USA, and/or its subsidiaries and/or its affiliates and/or their licensors.