Administering and Monitoring Business Processes 10.4 | Administering and Monitoring Business Processes | webMethods Audit Logging Guide | Setting Up IS Core Audit Logging | Set Up Additional Service Logging | Send Messages About Service Failures to Email Addresses
 
Send Messages About Service Failures to Email Addresses
You can configure Integration Server to automatically send notifications to a specified e-mail address each time a service fails. These service failures are the stack track data written to the error log. In a development environment, you might direct these messages to the developer. In a production environment, you might direct them to the Integration Server administrator.
* To send messages about service failures to e-mail addresses
1. In Integration Server Administrator, go to the Settings > Resources page and click Edit Resource Settings.
2. In the SMTP Server field, type the server name or IP address of the SMTP server to use to send the messages.
3. In the Internal Email field, type the e-mail address to which to send messages about critical log entries. Typically, you would specify the email address for the Integration Server administrator.
4. In the Service Email field, type the e-mail address to which to send messages about service failures. In a development environment, you might direct these messages to the developer. In a production environment, you might direct these messages to the Integration Server administrator.
5. By default, Integration Server uses character set UTF-8 for the messages. If you want to use a different character set, identify the character set in the Default Email Charset field.
6. Click Save Changes.
7. By default, Integration Server connects to port 25 on the specified SMTP server. Also by default, when sending a message, Integration Server provides its own address (the From Address) as Integration-Server@localhost, where localhost is the Integration Server host machine. If you want to change either of these properties, follow these steps:
a. In Integration Server Administrator, go to the Settings > Extended page. Integration Server Administrator displays a list of Integration Server configuration properties you can change using this method.
b. Click Edit Extended Settings. In the Extended Settings box, set the properties as follows:
To change this property
Set this parameter
SMTP server port
watt.server.smtpServerPort=port to use
Integration Server’s From Address
watt.server.email.from=new From Address to use
c. Click Save Changes, then restart Integration Server.