Software AG Products 10.11 | Administering Integration Server | Locking Administration and Best Practices | Disabling and Re-enabling Locking | Disabling Locking
 
Disabling Locking
To disable locking, you edit the extending settings using the Integration Server Administrator or manually edit server.cnf. The following procedure describes the Integration Server Administrator procedure.
Important:
Make sure that you only use this method of changing the settings. Later, if you change the settings by editing server.cnf, conflicts can occur.
*To disable locking on the Integration Server
1. Complete the tasks in Disabling and Re-enabling Locking.
2. Go to Settings > Extended.
3. Click Edit Extended Settings.
4. In the Extended Settings box, type a key and value according to the following table.
If you want to
Type this
Disable user locking and show no locks
watt.server.ns.lockingMode=none
Disable user locking but show system locks
watt.server.ns.lockingMode=system
5. Click Save Changes. The information is saved to Integration Server_directory \instances\instance_name\config\server.cnf.
6. Restart the Integration Server. The updated settings are now in effect.